TL;DR

This paper evaluates a simple 1D-CNN architecture for short-term electricity load forecasting (36-hour horizon) using aggregated household load data. It demonstrates that basic CNNs with optimized kernel size, filter count, and dense layer size achieve strong forecasting performance on both apartment building (40 households) and city district (350 households) load profiles, outperforming standard profiles without external features.

ABSTRACT

This paper presents a convolutional neural network (CNN) which can be used for forecasting electricity load profiles 36 hours into the future. In contrast to well established CNN architectures, the input data is one-dimensional. A parameter scanning of network parameters is conducted in order to gain information about the influence of the kernel size, number of filters, and dense size. The results show that a good forecast quality can already be achieved with basic CNN architectures.The method works not only for smooth sum loads of many hundred consumers, but also for the load of apartment buildings.

Motivation & Objective

  • To evaluate the performance of simple 1D-CNN architectures for short-term electricity load forecasting (STLF) in residential energy systems.
  • To identify the optimal combination of network hyperparameters—kernel size, number of filters, and dense layer size—for forecasting aggregated load profiles.
  • To assess whether minimal CNN architectures can outperform standard load profiles without incorporating external weather or temporal features.
  • To analyze the influence of model complexity on forecasting accuracy and generalization, particularly regarding overfitting.

Proposed method

  • A 1D-CNN model is trained on 15-minute resolution electricity load time series from 40 and 350 aggregated households.
  • The network architecture consists of a single 1D-convolutional layer with ReLU activation, followed by a global average pooling layer and a fully connected (dense) layer.
  • Hyperparameter scanning is performed across kernel size (3–15), number of filters (8–64), and dense layer size (1–16), with mean squared error (MSE) as the evaluation metric.
  • The model is trained and validated on time series data from the CER Smart Metering project, covering 18 months of Irish household data.
  • The forecasting horizon is set to 144 time steps (36 hours) at 15-minute intervals.
  • Results are visualized using heatmaps to analyze the interaction between hyperparameters and their impact on MSE.

Experimental results

Research questions

  • RQ1What is the optimal combination of kernel size, number of filters, and dense layer size for a simple 1D-CNN in short-term electricity load forecasting?
  • RQ2How does model complexity—measured by the number of parameters—impact forecasting accuracy and generalization?
  • RQ3Can a minimal 1D-CNN architecture outperform a standard load profile without incorporating external features like weather or calendar data?
  • RQ4How does the performance of the model vary between aggregated loads of 40 and 350 households?

Key findings

  • The best forecasting performance for the 350-household load profile is achieved with a dense layer size of 4–6 neurons, indicating that 4–6 features are sufficient to represent the time series.
  • For the 40-household load, the optimal configuration yields a significant reduction in MSE compared to the standard load profile, even with a simple architecture.
  • A dense layer size of 1 leads to substantially worse performance, confirming that an additional fully connected layer enhances forecast quality.
  • Overfitting occurs with large dense layer sizes, as evidenced by increased MSE, indicating that higher model complexity degrades performance.
  • Smaller kernel sizes (e.g., 3–5) tend to yield better results than very large or very small kernels, though the effect is less pronounced than with other hyperparameters.
  • The model achieves reliable forecasts on both 40- and 350-household load profiles with minimal architectural complexity, suggesting that simplicity is key for volatile load profiles.