[Paper Review] End-to-end deep meta modelling to calibrate and optimize energy consumption and comfort
This paper proposes an end-to-end deep meta-modelling framework that calibrates and optimizes energy consumption and thermal comfort in office buildings using a Recurrent Neural Network (RNN)-based metamodel trained on simulation data. By replacing computationally expensive physical simulators with a fast, differentiable surrogate model, the method enables efficient calibration of up to 60 unknown building parameters using only sparse sensor data, achieving up to 10% energy reduction while maintaining target comfort levels through multi-objective optimization.
In this paper, we propose a new end-to-end methodology to optimize the energy performance as well as comfort and air quality in large buildings without any renovation work. We introduce a metamodel based on recurrent neural networks and trained to predict the behavior of a general class of buildings using a database sampled from a simulation program. This metamodel is then deployed in different frameworks and its parameters are calibrated using the specific data of two real buildings. Parameters are estimated by comparing the predictions of the metamodel with real data obtained from sensors using the CMA-ES algorithm, a derivative free optimization procedure. Then, energy consumptions are optimized while maintaining a target thermal comfort and air quality, using the NSGA-II multi-objective optimization procedure. The numerical experiments illustrate how this metamodel ensures a significant gain in energy efficiency, up to almost 10%, while being computationally much more appealing than numerical models and flexible enough to be adapted to several types of buildings.
Motivation & Objective
- To address the challenge of optimizing energy consumption and thermal comfort in office buildings without costly renovations.
- To overcome the high computational cost of physical building simulation models during calibration and optimization.
- To develop a fast, differentiable surrogate model (metamodel) that accurately predicts building performance across diverse scenarios.
- To calibrate unknown building parameters (e.g., heat capacity, window area) using limited real sensor data from weakly instrumented buildings.
- To enable multi-objective optimization for energy savings and thermal comfort using the Pareto front, with minimal computational overhead.
Proposed method
- Train a Recurrent Neural Network (RNN) metamodel on thousands of simulation scenarios generated by a physical simulator (e.g., TRNSYS), using building geometry, weather, and HVAC settings as inputs.
- Use a derivative-free optimization procedure to calibrate the metamodel by minimizing the loss between predicted and real sensor data, estimating up to 60 unknown physical parameters.
- Apply multi-objective optimization using the Pareto front to find optimal HVAC settings that minimize energy use while preserving thermal comfort.
- Replace the original physical simulator with the trained RNN metamodel in the calibration and optimization pipeline, reducing computation time by over 70x.
- Compare RNNs with attention-based Transformer models to evaluate sequence modeling performance for building energy prediction.
- Fine-tune the metamodel using real building data to account for sensor noise and unmodeled dynamics not captured by the physical simulator.
Experimental results
Research questions
- RQ1Can a deep learning-based metamodel replace physical simulators in building energy calibration and optimization with acceptable accuracy and drastically reduced computation time?
- RQ2How effective is an RNN-based metamodel in estimating unknown building parameters (e.g., heat capacity, window-to-wall ratio) from sparse sensor data?
- RQ3To what extent can multi-objective optimization using the Pareto front reduce energy consumption while maintaining thermal comfort in real buildings?
- RQ4How does the performance of RNNs compare to attention-based models like Transformers in predicting building energy dynamics?
- RQ5Can the metamodel be adapted to real-world sensor noise and usage variability through fine-tuning, improving calibration robustness?
Key findings
- The RNN-based metamodel achieved a 70x reduction in computation time compared to TRNSYS, enabling feasible calibration of complex building models.
- Calibration converged in 300 iterations for the first building and 10,000 iterations for the second, which would have taken 100 days using TRNSYS.
- Energy consumption was reduced by 5.3% for the Stanley building and 9.9% for the Livingstone building while maintaining equivalent thermal comfort levels.
- By allowing a 0.5°C decrease in comfort, energy consumption was further reduced by up to 17%.
- The metamodel successfully estimated up to 60 unknown parameters (e.g., heat capacity, infiltration rate) from only a few sensors in weakly instrumented buildings.
- Fine-tuning the metamodel on real data improved prediction accuracy on unseen test periods, demonstrating robustness to sensor noise and usage variability.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.