[Paper Review] Energy Deposition along The Helical Undulator at ILC-250GeV
This study analyzes synchrotron radiation-induced power deposition in the superconducting helical undulator of the ILC-250GeV positron source, using analytical and HUSR simulation methods. It demonstrates that photon masks with 4.4 mm aperture, placed at 14.538 m intervals, reduce peak wall power deposition from 18.5 W/m to 0.022 W/m, ensuring compliance with the 1 W/m safety limit.
The positron source of the International Linear Collider is based on a superconducting helical undulator passed by the high-energy electron beam to generate photons which hit a conversion target. Since the photons are circularly polarized the resulting positron beam is polarized. At ILC250, the full undulator is needed to produce the required number of positrons. To keep the power deposition in the undulator walls below the acceptable limit of 1W/m, photon masks must be inserted in the undulator line. The photon mask design requires a detailed study of the power deposition in the walls and masks. This paper describes the power deposition in the undulator wall due to synchrotron radiation.
Motivation & Objective
- To quantify synchrotron radiation power deposition in the undulator walls due to relativistic electron beam passage.
- To evaluate the feasibility of using photon masks to reduce wall power deposition below the 1 W/m safety threshold.
- To determine the photon energy and flux distribution incident on masks for optimal material and geometric design.
- To compare analytical and HUSR simulation results for accuracy in ideal undulator conditions.
- To establish a foundation for future studies on non-ideal undulator effects and partial photon absorption.
Proposed method
- Used analytical formulation of angular power distribution from helical undulator radiation, based on relativistic synchrotron radiation theory.
- Applied the HUSR C++ code to simulate photon spectra and power deposition, validating results against analytical calculations.
- Tracked a 128 GeV electron beam through 132 undulator modules, each 1.75 m long, with K=0.85 and period 11.5 mm.
- Calculated total energy deposition from all modules analytically and compared with HUSR results for the first module.
- Modeled photon masks with 4.4 mm aperture placed at 14.538 m intervals behind quadrupoles to shield undulator walls.
- Analyzed radial power distribution on the last mask and energy spectra to inform material selection and shielding design.
Experimental results
Research questions
- RQ1What is the peak power deposition on the undulator wall from the first undulator module and from the full 231 m undulator?
- RQ2How effective are 4.4 mm photon masks in reducing wall power deposition to below 1 W/m?
- RQ3What is the energy spectrum and radial power distribution of photons incident on the last photon mask?
- RQ4How do analytical and HUSR simulation results compare for power deposition in the undulator wall?
- RQ5What are the implications of non-ideal undulator parameters and partial photon absorption on mask design?
Key findings
- The peak power deposition from the first undulator module is approximately 1.10 W/m.
- Total power deposition from all 132 modules reaches 18.5 W/m without masks.
- Photon masks with 4.4 mm aperture reduce peak wall power deposition to 0.022 W/m.
- The maximum photon energy incident on the last mask reaches 11 MeV, with an average of 1.93 MeV.
- The radial power distribution on the last mask peaks at 2.2 mm radius and decreases significantly toward 2.925 mm.
- The total incident power on the last photon mask is approximately 335 W, requiring robust thermal and radiation shielding design.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.