Skip to main content
QUICK REVIEW

[Paper Review] Enhancing Inertial Navigation Performance via Fusion of Classical and Quantum Accelerometers

Xuezhi Wang, Allison Kealy|arXiv (Cornell University)|Mar 17, 2021
Atomic and Subatomic Physics ResearchPhysics and Astronomy19 references9 citations
TL;DR

This paper proposes a maximum likelihood probabilistic fusion method that unwraps the phase of a quantum accelerometer using a classical accelerometer's output, enabling extended dynamic range and reduced drift. By re-calibrating the classical sensor at the quantum sensor's low sample rate, the fusion significantly improves inertial navigation accuracy, with simulations showing near-zero drift in fused acceleration error when using orthogonal-phase quantum sensors.

ABSTRACT

While quantum accelerometers sense with extremely low drift and low bias, their practical sensing capabilities face two limitations compared with classical accelerometers: a lower sample rate due to cold atom interrogation time, and a reduced dynamic range due to signal phase wrapping. In this paper, we propose a maximum likelihood probabilistic data fusion method, under which the actual phase of the quantum accelerometer can be unwrapped by fusing it with the output of a classical accelerometer on the platform. Consequently, the proposed method enables quantum accelerometers to be applied in practical inertial navigation scenarios with enhanced performance. The recovered measurement from the quantum accelerometer is also used to re-calibrate the classical accelerometer. We demonstrate the enhanced error performance achieved by the proposed fusion method using a simulated 1D inertial navigation scenario. We conclude with a discussion on fusion error and potential solutions.

Motivation & Objective

  • To address the limited dynamic range and low sample rate of quantum accelerometers in inertial navigation systems.
  • To overcome phase wrapping in quantum accelerometer signals, which restricts usable acceleration ranges.
  • To enhance classical accelerometer performance by using high-accuracy quantum measurements for periodic re-calibration.
  • To enable practical deployment of quantum accelerometers in real-world inertial navigation by fusing with classical sensors.
  • To minimize accumulated bias in classical sensors through probabilistic fusion with low-rate, high-accuracy quantum data.

Proposed method

  • Uses maximum likelihood estimation (MLE) to jointly estimate the true phase of the quantum accelerometer and the bias of the classical accelerometer.
  • Fuses the low-sample-rate quantum accelerometer output with the high-sample-rate classical accelerometer data at the quantum sensor's sampling rate.
  • Applies phase unwrapping by leveraging the classical accelerometer's continuous measurement to resolve ambiguous phase states in the quantum signal.
  • Employs a probabilistic model where the quantum sensor's sinusoidal output is mapped to acceleration via a nonlinear sine function, with MLE resolving the ambiguity.
  • Uses orthogonal-phase quantum accelerometers (0 and π/2) to access the linear sensitivity region of the sine response, minimizing nonlinear error.
  • Simulates the fusion process using Monte Carlo runs over 1000 trials to evaluate error performance in 1D inertial navigation.

Experimental results

Research questions

  • RQ1Can the phase wrapping problem in quantum accelerometers be effectively resolved using classical accelerometer data?
  • RQ2Can maximum likelihood estimation successfully fuse low-rate quantum data with high-rate classical data to improve navigation accuracy?
  • RQ3To what extent can the classical accelerometer's bias and drift be reduced through periodic re-calibration using quantum measurements?
  • RQ4How does the use of orthogonal-phase quantum sensors affect the linearity and accuracy of the fused output?
  • RQ5What is the impact of nonlinear sensitivity in the quantum sensor's sine response on fusion error, and how can it be mitigated?

Key findings

  • The fusion method successfully unwraps the quantum accelerometer's phase using classical sensor data, enabling operation beyond the sensor's native dynamic range.
  • The fused acceleration error remains near-zero over 4 hours when using orthogonal-phase quantum sensors, with drift dominated only by shot noise.
  • Classical accelerometer bias accumulates over time, but the fusion process effectively removes this drift through periodic re-calibration at the quantum sensor's sample rate.
  • Position error performance is substantially improved in the fusion method compared to using the classical accelerometer alone, as shown in 4-hour Monte Carlo simulations.
  • The use of orthogonal-phase quantum sensors (0 and π/2) allows access to the linear region of the sine response, reducing nonlinear sensitivity errors.
  • Fusion error increases with the magnitude of the underlying body acceleration, primarily due to the nonlinear mapping between signal phase and acceleration in the quantum sensor.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.