[Paper Review] Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals
This paper enhances the LUX-ZEPLIN (LZ) dark matter experiment's sensitivity to low-energy signals by optimizing S2-only and DPE (diffuse primary electron) analysis techniques, achieving up to three orders of magnitude improvement in sensitivity for dark matter masses down to 0.3 GeV/c², primarily through better background rejection and improved understanding of PMT response and electron lifetime.
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.
Motivation & Objective
- Improve the sensitivity of the LUX-ZEPLIN (LZ) experiment to low-mass dark matter signals below 1 GeV/c².
- Address the challenge of low-energy background suppression, particularly from 8 B neutrinos and grid events, to extend the experiment's reach to sub-GeV dark matter masses.
- Develop and validate new analysis techniques—S2-only and DPE—that exploit signal morphology and detector response to enhance low-threshold detection.
- Quantify the impact of detector parameters such as electron lifetime, PMT dark rates, and timing calibration on sensitivity at low energies.
- Enable future two-phase xenon experiments to extend their reach to sub-GeV dark matter by establishing robust, transferable analysis frameworks.
Proposed method
- Implement an S2-only analysis that uses pulse width information to reject grid backgrounds, significantly improving sensitivity at low masses.
- Apply the DPE (diffuse primary electron) technique to detect low-energy ionization signals by analyzing S2-only events with optimized S1 window cuts.
- Use the S2-only rate to tune cuts in the DPE analysis, relying on a well-calibrated PMT response model and DPE probability to minimize systematic uncertainty.
- Leverage the large fiducial volume of LZ to distinguish S2-only signals from bulk liquid xenon events, improving background discrimination.
- Integrate timing calibration and electron lifetime measurements via frequent calibrations and interpolation to reduce systematic errors in low-threshold analysis.
- Model and characterize S2-only background sources, which are the dominant source of systematic uncertainty in the S2-only analysis.
Experimental results
Research questions
- RQ1To what extent can the S2-only analysis improve LZ’s sensitivity to low-mass dark matter compared to the standard combined analysis?
- RQ2How does the DPE technique enhance sensitivity at sub-GeV dark matter masses, and what are the key dependencies on detector response and calibration?
- RQ3What is the impact of electron lifetime uncertainty and PMT dark rates on the sensitivity of low-threshold analyses in LZ?
- RQ4How do 8 B neutrino interactions affect the low-energy threshold, and can their tail be exploited to improve discovery potential?
- RQ5What role does precise timing calibration play in enabling S2-only analysis with minimal reliance on S1 window cuts?
Key findings
- The S2-only analysis improves LZ’s sensitivity at 2.5 GeV/c² by two orders of magnitude compared to the combined analysis, extending reach to lower masses.
- The DPE and S2-only techniques lower the dark matter mass threshold to 80 MeV/c², with the S2-only method achieving up to three orders of magnitude improvement in sensitivity for masses within its reach.
- The S2-only analysis achieves significant background rejection by exploiting pulse width, reducing sensitivity degradation from grid events and electron lifetime uncertainty.
- The analysis remains robust under a factor-of-two uncertainty in the S2-only rate, indicating that the DPE technique is a straightforward extension of the nominal analysis with modest sensitivity gains.
- Accurate measurement and frequent calibration of the electron lifetime are critical for maintaining sensitivity, particularly in low-threshold analyses.
- The S2-only method can rely solely on S1 window cuts if PMT dark rates and timing calibration are sufficiently precise, reducing reliance on rate-dependent tuning.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.