Skip to main content
QUICK REVIEW

[Paper Review] Fabrication and Characterization of an Amperometric Glucose Sensor on a Flexible Polyimide Substrate

Xiaosong Du, Christopher J. Durgan|arXiv (Cornell University)|Nov 22, 2014
Analytical Chemistry and SensorsChemical Engineering16 citations
TL;DR

This study presents a flexible, amperometric glucose sensor fabricated on a 12.7 µm polyimide substrate using additive manufacturing techniques including e-jet printing, electrochemical plating, and spin coating. The sensor achieves a linear response to glucose up to 32 mM with no interference from acetaminophen, and maintains enzyme activity after e-jet printing of glucose oxidase ink.

ABSTRACT

This study details the use of printing and other additive processes to fabricate a novel amperometric glucose sensor. The sensor was fabricated using a Au coated 12.7 micron polyimide film as a starting material, where micro-contact printing, electrochemical plating and chloridization, electrohydrodynamic jet (e-jet) printing, and spin coating were used to pattern, deposit, print, and coat functional materials, respectively. We have found that e-jet printing was effective for the deposition and patterning of glucose oxidase inks between ~5 to 1000 micron in width, and we have demonstrated that the enzyme was still active after printing. The thickness of the permselective layer was optimized to obtain a linear response to glucose concentration up to 32 mM. For these sensors no response to acetaminophen, a common interfering compound, was observed.

Motivation & Objective

  • To develop a flexible, wearable glucose sensor using low-cost, additive manufacturing techniques.
  • To enable precise patterning of glucose oxidase ink using e-jet printing on a thin polyimide substrate.
  • To optimize the permselective layer thickness for linear response to glucose concentrations up to 32 mM.
  • To minimize interference from common electroactive compounds such as acetaminophen.
  • To demonstrate functional enzyme activity post-printing for reliable biosensing performance.

Proposed method

  • Utilized gold-coated 12.7 µm polyimide film as a flexible, conductive substrate.
  • Applied micro-contact printing to define electrode patterns on the substrate.
  • Employed electrochemical plating and chloridization to modify electrode surfaces for enhanced sensitivity.
  • Used electrohydrodynamic jet (e-jet) printing to deposit glucose oxidase ink with feature widths from 5 to 1000 µm.
  • Applied spin coating to form a uniform permselective layer to control mass transport and improve selectivity.
  • Optimized the thickness of the permselective layer to achieve a linear amperometric response to glucose.

Experimental results

Research questions

  • RQ1Can e-jet printing effectively pattern glucose oxidase ink on a flexible polyimide substrate while preserving enzyme activity?
  • RQ2What is the optimal thickness of the permselective layer to achieve a linear response to glucose up to 32 mM?
  • RQ3Does the fabricated sensor exhibit selectivity against common interferents such as acetaminophen?
  • RQ4How do additive manufacturing techniques like e-jet printing and electrochemical plating contribute to sensor performance on flexible substrates?
  • RQ5Can the integration of multiple printing and coating processes yield a functional, flexible amperometric glucose sensor?

Key findings

  • E-jet printing successfully deposited glucose oxidase ink with feature widths ranging from 5 to 1000 µm, demonstrating high-resolution patterning on the flexible substrate.
  • Glucose oxidase retained its enzymatic activity after e-jet printing, confirmed by functional amperometric response to glucose.
  • The permselective layer thickness was optimized to yield a linear response to glucose concentrations up to 32 mM.
  • The sensor showed no detectable response to acetaminophen, indicating high selectivity against this common interferent.
  • The integration of micro-contact printing, electrochemical plating, e-jet printing, and spin coating enabled a fully additive fabrication process on a thin, flexible polyimide platform.
  • The final sensor design demonstrated stability and functionality suitable for wearable or implantable biosensing applications.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.