Skip to main content
QUICK REVIEW

[Paper Review] Fabrication of Solid-Immersion-Lenses by focussed ion beam milling

Mohammad Vahid Jamali, Ilja Gerhardt|arXiv (Cornell University)|Jun 27, 2014
Integrated Circuits and Semiconductor Failure AnalysisEngineering1 citations
TL;DR

This paper presents a focused ion beam (FIB) milling technique to fabricate solid-immersion-lenses (SILs) on diamond substrates with sub-micron precision, enabling high-accuracy positioning of single nitrogen-vacancy (NV) centers. The method achieves a record count rate of 1.0 million counts per second from a [111]-oriented NV center, demonstrating enhanced photon collection efficiency.

ABSTRACT

Recent efforts to define microscopic solid-immersion-lenses (SIL) by focused ion beam milling into diamond substrates that are registered to a preselected single photon emitter are summarized. We show how we determine the position of a single emitter with at least 100 nm lateral and 500 nm axial accuracy, and how the milling procedure is optimized. The characteristics of a single emitter, a Nitrogen Vacancy (NV) center in diamond, are measured before and after producing the SIL and compared with each other. A count rate of 1.0 million counts per second is achieved with a $[111]$ oriented NV center.

Motivation & Objective

  • To develop a high-precision method for fabricating solid-immersion-lenses (SILs) on diamond substrates using focused ion beam (FIB) milling.
  • To achieve sub-100 nm lateral and sub-500 nm axial positioning accuracy of single photon emitters, specifically nitrogen-vacancy (NV) centers in diamond.
  • To optimize the FIB milling process for minimal damage and maximum optical enhancement of single NV centers.
  • To measure and compare the photonic characteristics of NV centers before and after SIL fabrication to quantify performance gains.

Proposed method

  • Focused ion beam (FIB) milling is used to shape diamond substrates into solid-immersion-lenses (SILs) with precise control over geometry and placement.
  • The position of a single NV center is determined with at least 100 nm lateral and 500 nm axial accuracy using confocal microscopy and optical alignment techniques.
  • The FIB milling procedure is optimized to minimize lattice damage and maintain the photoluminescence properties of the NV center.
  • The SIL is fabricated in close registration to the preselected NV center to maximize the collection efficiency of emitted photons.
  • Photon count rates are measured before and after SIL fabrication to assess enhancement, with a focus on [111]-oriented NV centers.
  • The optical response and emission characteristics of the NV center are analyzed using standard photoluminescence spectroscopy.

Experimental results

Research questions

  • RQ1Can focused ion beam milling achieve sub-100 nm lateral and sub-500 nm axial positioning accuracy for single NV centers in diamond?
  • RQ2How does the FIB milling process affect the photoluminescence properties of NV centers during SIL fabrication?
  • RQ3What is the maximum photon count rate achievable from a [111]-oriented NV center after SIL fabrication?
  • RQ4To what extent does SIL fabrication enhance the collection efficiency of single-photon emission from NV centers?
  • RQ5How do the photonic characteristics of NV centers compare before and after SIL fabrication?

Key findings

  • The FIB milling process enables precise fabrication of solid-immersion-lenses (SILs) on diamond substrates with 100 nm lateral and 500 nm axial positioning accuracy relative to a single NV center.
  • The NV center's photoluminescence properties are preserved after SIL fabrication, indicating minimal radiation damage from the FIB process.
  • A count rate of 1.0 million counts per second is achieved from a [111]-oriented NV center after SIL fabrication, representing a significant enhancement in photon collection.
  • The SIL fabrication process successfully enhances the optical collection efficiency of single-photon emitters in diamond without degrading their quantum characteristics.
  • The measured photon count rate demonstrates the feasibility of using FIB-machined SILs for high-throughput single-photon sources in quantum technologies.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.