[Paper Review] Frequency comparisons and absolute frequency measurements of 171Yb+ single-ion optical frequency standards

E. Peik, B. Lipphardt|ArXiv.org|Apr 14, 2005
Advanced Frequency and Time StandardsPhysics and Astronomy11 citations
TL;DR

This paper presents high-precision frequency comparisons and absolute frequency measurements of 171Yb+ single-ion optical frequency standards using laser-cooled ions in Paul traps. By stabilizing two independent 171Yb+ systems to the 436 nm electric quadrupole transition, the authors achieve a relative instability of 5×10⁻¹⁶ at 1000 s, enabling sub-hertz resolution of systematic shifts. The key result is a stringent limit on the temporal variation of the fine structure constant: ∂α/∂t = (−0.3 ± 2.0)×10⁻¹⁵ yr⁻¹, the tightest constraint from atomic clock comparisons to date.

ABSTRACT

We describe experiments with an optical frequency standard based on a laser cooled $^{171}$Yb$^+$ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the $^2S_{1/2}(F=0)$ ground state to the $^2D_{3/2}(F=2)$ state at the wavelength of 436 nm is used as the reference transition. In order to compare two $^{171}$Yb$^+$ standards, separate frequency servo systems are employed to stabilize two probe laser frequencies to the reference transition line centers of two independently stored ions. The experimental results indicate a relative instability (Allan standard deviation) of the optical frequency difference between the two systems of $σ_y(1000 { m s})=5\cdot 10^{-16}$ only, so that shifts in the sub-hertz range can be resolved. Shifts of several hertz are observed if a stationary electric field gradient is superimposed on the radiofrequency trap field. The absolute optical transition frequency of Yb$^+$ at 688 THz was measured with a cesium atomic clock at two times separated by 2.8 years. A temporal variation of this frequency can be excluded within a $1σ$ relative uncertainty of $4.4\cdot 10^{-15}$ yr$^{-1}$. Combined with recently published values for the constancy of other transition frequencies this measurement provides a limit on the present variability of the fine structure constant $α$ at the level of $2.0\cdot 10^{-15}$ yr$^{-1}$.

Motivation & Objective

  • To evaluate the stability and systematic frequency shifts in 171Yb+ optical frequency standards using two independently trapped ions.
  • To measure the absolute frequency of the 436 nm 2S₁/₂(F=0)→2D₃/₂(F=2) transition with a cesium fountain clock.
  • To test the constancy of the fine structure constant α by combining data from 171Yb+, 199Hg+, and atomic hydrogen transitions.
  • To provide a model-independent constraint on the temporal variation of α and the Rydberg frequency using multiple atomic systems.

Proposed method

  • Two 171Yb+ ions are laser-cooled and confined in separate Paul traps using 370 nm and 935 nm lasers for cooling and repumping.
  • A diode laser at 871 nm is frequency-doubled to probe the 436 nm reference transition, with stabilization to the line center via alternating probe pulses and excitation probability difference feedback.
  • Independent frequency servo systems stabilize two probe lasers to the line centers of two separate ions, enabling direct frequency comparison.
  • The absolute optical frequency is measured relative to a cesium fountain clock over a 2.8-year interval to assess long-term stability.
  • Systematic shifts are evaluated by applying a static electric field gradient to the trap, observing sub-hertz frequency shifts.
  • Data from 171Yb+, 199Hg+, and hydrogen 1S→2S transitions are combined in a weighted linear regression to constrain ∂α/∂t and ∂Ry/∂t.

Experimental results

Research questions

  • RQ1What is the short-term stability of the 171Yb+ optical frequency standard when comparing two independently trapped ions?
  • RQ2How do systematic shifts, such as those from electric field gradients, affect the 171Yb+ transition frequency?
  • RQ3What is the absolute frequency of the 436 nm 2S₁/₂(F=0)→2D₃/₂(F=2) transition in 171Yb+ relative to a cesium clock?
  • RQ4What is the most stringent limit on the temporal variation of the fine structure constant α based on optical frequency comparisons?
  • RQ5What is the constraint on the drift rate of the Rydberg frequency derived from combined atomic clock data?

Key findings

  • The relative instability of the frequency difference between two 171Yb+ standards is σy(1000 s) = 5×10⁻¹⁶, enabling resolution of shifts in the sub-hertz range.
  • A static electric field gradient induces frequency shifts of several hertz, confirming sensitivity to external fields.
  • The absolute optical transition frequency of 171Yb+ at 688 THz shows no measurable drift over 2.8 years, with a 1σ uncertainty of 4.4×10⁻¹⁵ yr⁻¹.
  • Combining 171Yb+ data with published 199Hg+ and hydrogen 1S→2S measurements yields a limit on the temporal variation of α: ∂α/∂t = (−0.3 ± 2.0)×10⁻¹⁵ yr⁻¹ at 1σ confidence.
  • The analysis also constrains the drift rate of the Rydberg frequency to ∂Ry/∂t = (−1.6 ± 3.2)×10⁻¹⁵ yr⁻¹, consistent with zero.
  • The combined constraint on α variability approaches the sensitivity of quasar observations, within a factor of three, under the assumption of linear evolution over cosmological timescales.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.