Skip to main content
QUICK REVIEW

[Paper Review] GASP - Galway Astronomical Stokes Polarimeter

Patrick P. Collins, Brendan Shehan|ArXiv.org|May 1, 2009
Stellar, planetary, and galactic studiesPhysics and Astronomy2 references4 citations
TL;DR

GASP is an ultra-high-speed, full-Stokes astronomical imaging polarimeter based on Division of Amplitude Polarimetry (DOAP) that measures all Stokes parameters (I, Q, U, V) simultaneously in a single exposure using a modified Fresnel rhomb as a beamsplitter and quarter-wave plate. It achieves 1% calibration accuracy via the Eigenvalue Calibration Method, enabling precise detection of rapid stochastic polarization variations in objects like optical pulsars and gamma-ray burst afterglows.

ABSTRACT

The Galway Astronomical Stokes Polarimeter (GASP) is an ultra-high-speed, full Stokes, astronomical imaging polarimeter based upon a Division of Amplitude Polarimeter. It has been developed to resolve extremely rapid stochastic, millisecond variations in objects such as optical pulsars, RRATs and magnetic cataclysmic variables. GASP has no moving parts or modulated components, so the complete Stokes vector can be measured from just one exposure - making it unique to astronomy. Furthermore the time required for the determination of the full Stokes vector is limited only by the time resolution of the detectors used and the incident photon fluxes. GASP utilizes a modified Fresnel rhomb, which acts as a highly achromatic quarter wave plate and a beamsplitter (referred to as an RBS). Here we present a description of how the DOAP works, some of the optical designs for the polarimeter, and give some preliminary results. Calibration is an important, and difficult issue with all polarimeters, but particularly in astronomical polarimeters. We give a description of calibration techniques appropriate to this type of polarimeter, particularly the Eigenvalue Calibration Method of Compain & Drevillon

Motivation & Objective

  • To develop a high-time-resolution polarimeter capable of measuring full Stokes vectors in a single exposure for rapidly varying astronomical polarization phenomena.
  • To address the limitations of traditional rotating waveplate and Wollaston prism systems in capturing stochastic polarization changes on millisecond timescales.
  • To design a moving-part-free polarimeter with high temporal resolution limited only by detector performance and photon flux.
  • To implement a robust calibration method that eliminates instrumental polarization and ensures sub-1% accuracy in polarization measurements.
  • To enable target-of-opportunity observations of transient events such as gamma-ray burst afterglows and optical counterparts of new Fermi gamma-ray pulsars.

Proposed method

  • GASP employs Division of Amplitude Polarimetry (DOAP), where the incoming beam is split by a modified Fresnel rhomb (RBS) into two beams with equal intensity and a quarter-wave retardance.
  • The RBS acts as both a beamsplitter and a highly achromatic quarter-wave plate, enabling simultaneous measurement of linear and circular polarization components.
  • Each beam is then directed through a Wollaston prism to separate orthogonal polarization states, producing four output beams whose intensities are measured by EMCCD or APD detectors.
  • The system uses the linear relationship I = A·S, where I is the measured intensity vector, A is the system matrix, and S is the input Stokes vector, allowing S to be retrieved via S = I·A⁻¹.
  • Calibration is performed using the Eigenvalue Calibration Method (ECM), which determines error correction matrices by measuring Mueller matrices of four known polarization standards: air, 0° and 90° polarizers, and a 28°-aligned QWP.
  • The calibration process ensures instrumental polarization is eliminated, and the system is verified using standard stars with known polarization states.

Experimental results

Research questions

  • RQ1Can a moving-part-free, full-Stokes polarimeter achieve millisecond-level time resolution for stochastic polarization phenomena?
  • RQ2How accurately can a DOAP-based system measure the full Stokes vector in a single exposure without mechanical modulation?
  • RQ3Can the Eigenvalue Calibration Method (ECM) achieve sub-1% accuracy in calibrating a high-speed astronomical polarimeter?
  • RQ4To what extent does the system maintain consistent polarization degree and angle under instrument rotation, confirming correct matrix calibration?
  • RQ5Can the polarimeter detect and characterize rapid polarization variations equivalent to those expected from optical pulsars and gamma-ray burst afterglows?

Key findings

  • GASP successfully measured the degree of linear polarization of the 50% polarized standard star CRL 2688 with consistent results across 0.1 s exposures, demonstrating stability and low noise.
  • The measured polarization angle varied precisely with instrument rotation, confirming that the system matrix A was correctly calibrated and invertible for accurate Stokes vector retrieval.
  • Fluctuations in Stokes I and U/Q intensities matched Poisson noise models, indicating that photon-limited noise was the dominant source of uncertainty.
  • The system achieved 1% calibration accuracy using the Eigenvalue Calibration Method, enabling reliable polarization measurements of astronomical sources.
  • On the 1.5m Cassini telescope, 0.1 s exposures with GASP correspond to approximately 5 ms time resolution for a Crab pulsar observation on an 8m telescope, proving feasibility for pulsar studies.
  • Instrument rotation tests confirmed that the degree of polarization remained constant while the angle varied linearly with rotation, validating the system's ability to correctly resolve polarization states in real time.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.