Skip to main content
QUICK REVIEW

[Paper Review] Heat Transfer in Underground Rail Tunnels

Stefan Sadokierski, Jean‐Luc Thiffeault|ArXiv.org|Sep 12, 2007
Aerodynamics and Fluid Dynamics ResearchEngineering14 references8 citations
TL;DR

This paper develops a coupled thermal model for underground rail tunnels that accounts for transient heat transfer between tunnel air and surrounding soil, incorporating turbulent flow profiles and radial conduction. It shows that train-induced fluctuations in heat transfer coefficient act as an effective additional heat source, raising mean soil temperature and invalidating steady-state assumptions, with key results showing significant phase shifts and thermal mass effects over daily and seasonal cycles.

ABSTRACT

The transfer of heat between the air and surrounding soil in underground tunnels ins investigated, as part of the analysis of environmental conditions in underground rail systems. Using standard turbulent modelling assumptions, flow profiles are obtained in both open tunnels and in the annulus between a tunnel wall and a moving train, from which the heat transfer coefficient between the air and tunnel wall is computed. The radial conduction of heat through the surrounding soil resulting from changes in the temperature of air in the tunnel are determined. An impulse change and an oscillating tunnel air temperature are considered separately. The correlations between fluctuations in heat transfer coefficient and air temperature are found to increase the mean soil temperature. Finally, a model for the coupled evolution of the air and surrounding soil temperature along a tunnel of finite length is given.

Motivation & Objective

  • To address the limitations of steady-state models in predicting temperature evolution in underground rail tunnels, particularly the phase shifts observed in real systems.
  • To model the coupled thermal dynamics of tunnel air and surrounding soil, accounting for the thermal mass and conductivity of the ground.
  • To quantify the impact of short-term fluctuations in heat transfer coefficient caused by passing trains on long-term soil temperature profiles.
  • To develop a dynamic model that captures the effects of 'night flushing' and seasonal variations on peak tunnel temperatures.
  • To improve predictive accuracy for thermal management in underground rail systems by integrating fluid dynamics and transient conduction.

Proposed method

  • Derives turbulent flow profiles in open tunnels and in the train-tunnel annulus using standard turbulent flow assumptions and friction velocity formulations.
  • Computes heat transfer coefficients (ht and hv) at tunnel walls and train surfaces using wall shear stress and air velocity, based on Newton’s law of cooling.
  • Solves the radial heat conduction equation in cylindrical coordinates from the tunnel wall to infinity, with a time-varying boundary condition at the inner radius.
  • Applies analytic solutions to model heat diffusion into the soil under impulse and oscillating temperature inputs, using thermal diffusivity and conductivity parameters.
  • Introduces a correlation between short-term fluctuations in heat transfer coefficient and tunnel air temperature, modeling it as an effective heat source.
  • Develops a coupled model for axial air temperature evolution and radial soil temperature diffusion, incorporating a continuous inhomogeneous heat source along the tunnel.

Experimental results

Research questions

  • RQ1How do short-term fluctuations in heat transfer coefficient due to passing trains affect the mean temperature of surrounding soil?
  • RQ2To what extent does the thermal mass of the surrounding soil cause phase shifts in tunnel air temperature over daily and seasonal cycles?
  • RQ3Why do standard steady-state models fail to predict the observed warming of the London Underground in autumn compared to spring under identical ambient conditions?
  • RQ4What is the impact of 'night flushing' on the following day’s peak tunnel temperature, and how can it be accurately modeled?
  • RQ5How does the effective heat transfer coefficient vary between open tunnels and the train-tunnel annulus, and what are the implications for thermal load distribution?

Key findings

  • Short-term fluctuations in heat transfer coefficient caused by trains introduce a correlation with air temperature that acts as an effective additional heat source, increasing the mean soil temperature by up to 1.5 K in the model.
  • The thermal boundary layer for daily oscillations is approximately 0.1 m thick, while for annual oscillations it extends to about 1.8 m, indicating strong seasonal penetration.
  • The decay time for temperature fluctuations in the open tunnel is ~5.3 days (4.56 × 10⁶ s), while in the annulus it is ~5.3 hours (4.56 × 10⁵ s), showing faster dissipation in the train-adjacent region.
  • The effective heat transfer coefficient for the open tunnel is 127 m⁻¹ (Ht = ht/Ks), and for the annulus it is 314 m⁻¹ (Hv = hv/Ks), indicating significantly stronger coupling in the train-tunnel gap.
  • The model predicts that the phase shift between ambient air and tunnel air temperature is due to the thermal inertia of the soil, explaining why the Underground is warmer in autumn than spring.
  • The inclusion of time-varying heat transfer coefficients and radial conduction allows the model to capture transient effects such as night flushing, which steady-state models cannot predict.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.