[Paper Review] High Precision Radial Velocity Measurements in the Infrared: A First Assessment of the RV Stability of CRIRES

Andreas Seifahrt, H. U. Käufl|ArXiv.org|Sep 8, 2008
Stellar, planetary, and galactic studiesPhysics and Astronomy16 references24 citations
TL;DR

This paper evaluates the short-term radial velocity (RV) stability of the CRIRES spectrograph at the VLT, demonstrating a stability of ±10 m/s for telluric lines and ±20 m/s for stellar RV measurements using Earth's atmosphere as a local rest frame. The study confirms CRIRES is suitable for high-precision infrared RV work, especially when combined with telluric lines or gas-cell calibration.

ABSTRACT

High precision radial velocity (RV) measurements in the near infrared are on high demand, especially in the context of exoplanet search campaigns shifting their interest to late type stars in order to detect planets with ever lower mass or targeting embedded pre-main-sequence objects. ESO is offering a new spectrograph at the VLT -- CRIRES -- designed for high resolution near-infrared spectroscopy with a comparably broad wavelength coverage and the possibility to use gas-cells to provide a stable RV zero-point. We investigate here the intrinsic short-term RV stability of CRIRES, both with gas-cell calibration data and on-sky measurements using the absorption lines of the Earth's atmosphere imprinted in the source spectrum as a local RV rest frame. Moreover, we also investigate for the first time the intrinsic stability of telluric lines at 4100 nm for features originating in the lower troposphere. Our analysis of nearly 5 hours of consecutive observations of MS Vel, a M2II bright giant centred at two SiO first overtone band-heads at 4100 nm, demonstrates that the intrinsic short-term stability of CRIRES is very high, showing only a slow and fully compensateable drift of up to 60 m/s after 4.5 hours. The radial velocity of the telluric lines is constant down to a level of approx. +/- 10 m/s (or 7/1000 of one pixel). Utilising the same telluriclines as a rest frame for our radial velocity measurements of the science target, we obtain a constant RV with a precision of approx. +/- 20 m/s for MS Vel as expected for a M-giant.

Motivation & Objective

  • To evaluate the intrinsic short-term radial velocity stability of the CRIRES spectrograph in the near-infrared.
  • To investigate the stability of telluric absorption lines at 4100 nm as a local rest frame for RV measurements.
  • To assess the feasibility of using atmospheric absorption lines as a substitute for gas-cell calibration in high-precision RV work.
  • To determine the impact of instrumental drift, thermal effects, and source alignment on RV precision.
  • To establish the performance baseline for future long-term RV monitoring campaigns with CRIRES.

Proposed method

  • Conducted nearly 5 hours of consecutive on-sky observations of the M2II giant MS Vel using CRIRES in cryogenic, adaptive optics mode.
  • Used telluric absorption lines at 4100 nm—originating in the lower troposphere—as a local rest frame for radial velocity measurements.
  • Compared RV measurements of the star MS Vel against the stable telluric lines to assess instrumental drift and stability.
  • Analyzed gas-cell calibration data to assess the intrinsic stability of the spectrograph's wavelength solution.
  • Measured the radial velocity drift of the spectrograph over time, identifying a slow 60 m/s drift over 4.5 hours.
  • Evaluated the impact of PSF misalignment, guiding errors, and atmospheric refraction on wavelength calibration stability.

Experimental results

Research questions

  • RQ1What is the intrinsic short-term radial velocity stability of the CRIRES spectrograph in the near-infrared?
  • RQ2Can telluric absorption lines at 4100 nm serve as a stable local rest frame for high-precision RV measurements?
  • RQ3How does instrumental drift, such as thermal or flexure effects, affect RV precision over time?
  • RQ4To what extent can atmospheric telluric lines be used as a substitute for gas-cell calibration in RV surveys?
  • RQ5What are the dominant sources of wavelength shift uncertainty in AO-fed, cryogenic spectrographs like CRIRES?

Key findings

  • The intrinsic short-term RV stability of CRIRES is very high, with a slow drift of up to 60 m/s over 4.5 hours of observation.
  • Telluric absorption lines at 4100 nm exhibit radial velocity stability at the level of ±10 m/s (or 7/1000 of a pixel).
  • The radial velocity of the M2II giant MS Vel was measured with a precision of ±20 m/s when using telluric lines as a rest frame.
  • The residual RV scatter in the stellar spectrum after correcting for Earth's motion was ≤ ±22 m/s, indicating high measurement fidelity.
  • Telluric lines imprinted in the science target's spectrum are not a limiting factor for high-precision RV work and can serve as a reliable local rest frame.
  • Gas-cell calibration remains superior for sub-20 m/s precision, but telluric lines provide a viable alternative when gas cells are unavailable or blended.