Skip to main content
QUICK REVIEW

[Paper Review] Hybrid quantum convolutional neural networks model for COVID-19 prediction using chest X-Ray images

Essam H. Houssein, Zainab Abohashima|arXiv (Cornell University)|Feb 8, 2021
COVID-19 diagnosis using AIMedicine52 references14 citations
TL;DR

This paper proposes a hybrid quantum-classical convolutional neural network (HQCNN) that leverages random quantum circuits (RQCs) as a quantum convolutional layer to classify COVID-19 from chest X-ray (CXR) images. The model achieves 99% accuracy and 99.7% sensitivity on binary COVID-19 vs. pneumonia datasets, outperforming classical models in key metrics including AUC-ROC, F1-score, and balanced accuracy.

ABSTRACT

Despite the great efforts to find an effective way for COVID-19 prediction, the virus nature and mutation represent a critical challenge to diagnose the covered cases. However, developing a model to predict COVID-19 via Chest X-Ray (CXR) images with accurate performance is necessary to help in early diagnosis. In this paper, a hybrid quantum-classical convolutional Neural Networks (HQCNN) model used the random quantum circuits (RQCs) as a base to detect COVID-19 patients with CXR images. A collection of 6952 CXR images, including 1161 COVID-19, 1575 normal, and 5216 pneumonia images, were used as a dataset in this work. The proposed HQCNN model achieved higher performance with an accuracy of 98.4\% and a sensitivity of 99.3\% on the first dataset cases. Besides, it obtained an accuracy of 99\% and a sensitivity of 99.7\% on the second dataset cases. Also, it achieved accuracy, and sensitivity of 88.6\%, and 88.7\%, respectively, on the third multi-class dataset cases. Furthermore, the HQCNN model outperforms various models in balanced accuracy, precision, F1-measure, and AUC-ROC score. The experimental results are achieved by the proposed model prove its ability in predicting positive COVID-19 cases.

Motivation & Objective

  • To address the challenge of early and accurate detection of COVID-19 using low-cost, widely available CXR imaging.
  • To overcome limitations of classical deep learning models in handling high-dimensional medical image features and computational inefficiency.
  • To explore the integration of quantum computing with convolutional neural networks for improved medical image classification.
  • To evaluate the performance of a hybrid quantum-classical model on imbalanced and multi-class CXR datasets for COVID-19 diagnosis.
  • To demonstrate the superiority of quantum-enhanced convolutional layers over classical counterparts in diagnostic accuracy and robustness.

Proposed method

  • The HQCNN model integrates a random quantum circuit (RQC) as a quantum convolutional layer to compute kernel operations in high-dimensional feature space.
  • The RQC is implemented using parameterized quantum gates (specifically Ry angle encoding) and executed on a quantum simulator with 1000 shots for optimal performance.
  • The quantum layer is embedded within a classical CNN architecture, where quantum features are extracted and fed into fully connected layers for classification.
  • The model is trained on three datasets: binary (normal vs. COVID-19), binary (COVID-19 vs. pneumonia), and multi-class (normal, COVID-19, pneumonia) CXR images.
  • Performance is evaluated using standard metrics: accuracy, sensitivity, precision, F1-measure, and AUC-ROC, with comparisons to state-of-the-art models.
  • Hyperparameter tuning is performed using angle encoding (Ry gate) and shot count (1000 shots) to optimize model performance.

Experimental results

Research questions

  • RQ1Can a hybrid quantum-classical CNN model improve the accuracy and sensitivity of COVID-19 detection in CXR images compared to classical deep learning models?
  • RQ2How does the integration of random quantum circuits as a convolutional layer enhance feature representation in medical image classification?
  • RQ3What is the optimal configuration of quantum circuit parameters (e.g., gate type, number of shots) for diagnosing COVID-19 from CXR images?
  • RQ4How does the HQCNN model perform on imbalanced datasets, particularly in distinguishing between normal, pneumonia, and COVID-19 cases?
  • RQ5To what extent does the HQCNN model outperform existing state-of-the-art models in key diagnostic metrics such as AUC-ROC and F1-score?

Key findings

  • The HQCNN model achieved 99% accuracy and 99.7% sensitivity on the binary dataset (COVID-19 vs. pneumonia), with an AUC-ROC score of 100%.
  • On the binary dataset (normal vs. COVID-19), the model reached 98.4% accuracy and 99.3% sensitivity, demonstrating high detection capability for positive cases.
  • For the multi-class dataset (normal, COVID-19, pneumonia), the model recorded 88.6% accuracy and 88.7% sensitivity, with the highest F1-score of 98% for the COVID-19 class.
  • The model outperformed multiple classical models—including VGG16, EfficientNet, InceptionNet, and CoroNet—in balanced accuracy, precision, F1-measure, and AUC-ROC across all datasets.
  • The model achieved 100% precision and 99% sensitivity for pneumonia cases in the binary dataset, indicating strong generalization for non-COVID-19 lung conditions.
  • The use of Ry angle encoding with 1000 shots yielded the best performance, confirming its importance in optimizing quantum feature extraction.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.