[Paper Review] iGOS++: Integrated Gradient Optimized Saliency by Bilateral Perturbations
iGOS++ introduces a novel saliency method that optimizes for both deletion and insertion masks to improve localization fidelity in deep learning explanations. By incorporating a bilateral total variation regularization, it generates smoother, more interpretable heatmaps, especially at high resolutions, and reveals hidden data biases—such as overfitting to text in medical X-rays—leading to significant performance gains in explainable AI.
The black-box nature of the deep networks makes the explanation for "why" they make certain predictions extremely challenging. Saliency maps are one of the most widely-used local explanation tools to alleviate this problem. One of the primary approaches for generating saliency maps is by optimizing a mask over the input dimensions so that the output of the network is influenced the most by the masking. However, prior work only studies such influence by removing evidence from the input. In this paper, we present iGOS++, a framework to generate saliency maps that are optimized for altering the output of the black-box system by either removing or preserving only a small fraction of the input. Additionally, we propose to add a bilateral total variation term to the optimization that improves the continuity of the saliency map especially under high resolution and with thin object parts. The evaluation results from comparing iGOS++ against state-of-the-art saliency map methods show significant improvement in locating salient regions that are directly interpretable by humans. We utilized iGOS++ in the task of classifying COVID-19 cases from x-ray images and discovered that sometimes the CNN network is overfitted to the characters printed on the x-ray images when performing classification. Fixing this issue by data cleansing significantly improved the precision and recall of the classifier.
Motivation & Objective
- To address the limitations of existing saliency methods that focus only on removing evidence, leading to fragmented and non-continuous masks.
- To improve saliency map quality at high resolutions by introducing a bilateral total variation regularization term that enhances smoothness and continuity.
- To enable more faithful and human-interpretable explanations by simultaneously optimizing for both mask deletion and insertion effects.
- To detect and diagnose hidden data biases in deep learning models, particularly in medical imaging pipelines where spurious correlations (e.g., text in X-rays) can mislead classifiers.
- To validate the method on both natural images and real-world medical data, demonstrating its utility in debugging and improving model reliability.
Proposed method
- iGOS++ optimizes two separate masks: a deletion mask that removes input features and an insertion mask that preserves only the most salient features.
- The method uses a dual-objective loss function that minimizes the network’s prediction confidence when the deletion mask is applied and maximizes it when the insertion mask is applied.
- A novel bilateral total variation (BTV) regularization term is introduced to enforce spatial smoothness in saliency maps by leveraging image color similarity and edge-aware smoothing.
- The BTV term is computed using a weighted average of pixel differences, where weights are based on color and spatial proximity, reducing heatmap diffusion at high resolutions.
- The final saliency map is derived from the combined optimization of both masks, ensuring that the most informative regions are highlighted without fragmentation.
- The framework is applied end-to-end to deep networks, with gradients backpropagated through the optimization to generate high-resolution, continuous heatmaps.
Experimental results
Research questions
- RQ1Can jointly optimizing for both deletion and insertion of input features lead to more accurate and continuous saliency maps than methods that only consider deletion?
- RQ2Does the introduction of a bilateral total variation regularization term significantly improve the smoothness and interpretability of saliency maps, especially at high resolutions?
- RQ3Can iGOS++ detect and expose hidden data biases in deep learning models, such as overfitting to non-clinical artifacts like text in medical images?
- RQ4How does iGOS++ perform in comparison to state-of-the-art saliency methods in terms of localization accuracy and robustness across different image resolutions?
- RQ5To what extent can iGOS++ improve model reliability by revealing spurious correlations in real-world medical imaging datasets?
Key findings
- iGOS++ achieved 99.2% classification confidence on a tiger beetle image using only 6% of the most salient pixels, as identified by the insertion mask, demonstrating superior feature retention and localization.
- The method significantly outperformed prior approaches like I-GOS in maintaining high prediction confidence at high resolutions, with less fragmented and more coherent saliency maps.
- In the medical imaging case study, iGOS++ revealed that the classifier was overfitting to text characters (e.g., 'R') on X-ray images, which were sufficient to trigger false COVID-19 predictions.
- After removing text-containing regions from the training data, the classifier’s precision and recall improved meaningfully, confirming that the model had learned spurious correlations.
- The bilateral total variation term effectively reduced heatmap diffusion and improved smoothness, especially in regions with thin or elongated structures like beetle legs.
- The insertion-only visualization capability of iGOS++ enabled the detection of critical model bugs that were undetected by standard saliency methods, proving its value in model debugging.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.