TL;DR

This paper presents a collaborative robot system that integrates a standard manual pipette for flexible, high-precision liquid dispensing in laboratory settings. By combining direct teaching for labware pose recognition, motion planning, and vision-based error correction using a vision transformer, the system achieves robust tip attachment and dispensing without lab modifications, enabling quick deployment in crowded labs for low-frequency, high-repetition biochemical tasks.

ABSTRACT

This paper presents a system integration approach for a 6-DoF (Degree of Freedom) collaborative robot to operate a pipette for liquid dispensing. Its technical development is threefold. First, we designed an end-effector for holding and triggering manual pipettes. Second, we took advantage of a collaborative robot to recognize labware poses and planned robotic motion based on the recognized poses. Third, we developed vision-based classifiers to predict and correct positioning errors and thus precisely attached pipettes to disposable tips. Through experiments and analysis, we confirmed that the developed system, especially the planning and visual recognition methods, could help secure high-precision and flexible liquid dispensing. The developed system is suitable for low-frequency, high-repetition biochemical liquid dispensing tasks. We expect it to promote the deployment of collaborative robots for laboratory automation and thus improve the experimental efficiency without significantly customizing a laboratory environment.

Motivation & Objective

  • To enable collaborative robots to perform flexible, high-repetition biochemical liquid dispensing tasks in existing lab environments without requiring special-purpose infrastructure.
  • To address the challenge of integrating standard manual pipettes—commonly used in labs—into robotic systems without modifying the pipettes or labware.
  • To develop a low-cost, rapidly deployable robotic solution that operates safely alongside humans and existing automation systems.
  • To improve tip attachment accuracy through vision-based deviation prediction and closed-loop correction, ensuring robustness in real-world conditions.

Proposed method

  • Modified a commercial 6-DoF collaborative robot with a custom end-effector featuring dual-finger parallel grippers and embedded RGB cameras to hold and trigger a manual pipette.
  • Utilized the robot’s direct teaching mode to recognize initial poses of labware (tip racks and microplates) without pre-programming, enabling flexible setup in variable configurations.
  • Implemented interleaved search and motion planning to generate real-time robot trajectories based on recognized labware poses, supporting dynamic reconfiguration.
  • Formulated tip attachment as a peg-in-hole task and employed a vision transformer-based classifier to detect alignment deviations between pipette shaft and tip.
  • Applied open-loop and closed-loop visual feedback: closed-loop updates improved robustness by propagating correction results across sequential tip attachments.
  • Collected real-world training data for vision classifiers by simulating diverse tip misalignments and measuring correction steps, enhancing generalization.

Experimental results

Research questions

  • RQ1Can a collaborative robot reliably attach disposable tips to a manual pipette using vision-based error detection and correction?
  • RQ2How does the integration of direct teaching and motion planning enable flexible deployment in unstructured lab environments with randomly placed labware?
  • RQ3What is the impact of closed-loop visual feedback on tip attachment success rate and correction efficiency compared to open-loop methods?
  • RQ4To what extent can the system handle workspace boundary effects and positioning errors near the robot’s operational limits?
  • RQ5Can the system be deployed alongside existing automation systems (e.g., RIPPS) for synchronized liquid dispensing and analysis tasks?

Key findings

  • The system achieved robust tip attachment across all tested configurations, with only two failed tips in the third rack configuration due to high absolute positioning errors near the robot’s workspace boundary.
  • Closed-loop visual feedback reduced correction steps and improved success rates, especially for tips farther from the reference point (ID 0), by mitigating cumulative error propagation.
  • The vision transformer classifier successfully detected alignment deviations, with darker grids in visualizations indicating higher correction steps for misaligned poses, and failure cases were traced to misrecognition and high positioning error.
  • The system demonstrated high flexibility by enabling rapid setup in narrow, unmodified lab spaces without requiring safety fencing or specialized labware.
  • Integration with the RIPPS plant phenotyping system enabled synchronized chemical dispensing to plant pots, confirming compatibility with existing automation workflows.
  • The method achieved high-precision liquid dispensing without customizing the lab environment, supporting low-frequency, high-repetition experiments efficiently.

Read this paper