[Paper Review] Interpretable and Intervenable Ultrasonography-based Machine Learning Models for Pediatric Appendicitis
This paper proposes interpretable and intervenable machine learning models for pediatric appendicitis using abdominal ultrasound images, leveraging a novel multiview concept bottleneck model (MVCBM) that enables clinicians to interact with high-level, clinically meaningful concepts. The model achieves an AUROC of 0.80 and AUPR of 0.92 for diagnosis prediction, matching black-box neural networks while maintaining interpretability and real-time usability without requiring image annotation.
Appendicitis is among the most frequent reasons for pediatric abdominal surgeries. Previous decision support systems for appendicitis have focused on clinical, laboratory, scoring, and computed tomography data and have ignored abdominal ultrasound, despite its noninvasive nature and widespread availability. In this work, we present interpretable machine learning models for predicting the diagnosis, management and severity of suspected appendicitis using ultrasound images. Our approach utilizes concept bottleneck models (CBM) that facilitate interpretation and interaction with high-level concepts understandable to clinicians. Furthermore, we extend CBMs to prediction problems with multiple views and incomplete concept sets. Our models were trained on a dataset comprising 579 pediatric patients with 1709 ultrasound images accompanied by clinical and laboratory data. Results show that our proposed method enables clinicians to utilize a human-understandable and intervenable predictive model without compromising performance or requiring time-consuming image annotation when deployed. For predicting the diagnosis, the extended multiview CBM attained an AUROC of 0.80 and an AUPR of 0.92, performing comparably to similar black-box neural networks trained and tested on the same dataset.
Motivation & Objective
- To develop interpretable and intervenable machine learning models for pediatric appendicitis using ultrasound imaging, addressing the gap in clinical usability of existing AI tools.
- To enable clinicians to interact with and modify predictions through high-level, human-understandable concepts such as 'appendix diameter' or 'free fluid'.
- To extend concept bottleneck models (CBM) to handle multiple ultrasound views and incomplete concept sets, improving robustness in real-world clinical settings.
- To validate the model on a publicly available dataset of 579 pediatric patients with 1,709 ultrasound images, ensuring reproducibility and clinical relevance.
- To deploy a web-based demo tool for real-time, interactive model use, promoting clinical adoption and trust.
Proposed method
- The study employs a concept bottleneck model (CBM) framework, where predictions are made based on intermediate, clinically interpretable concepts rather than raw pixels.
- A multiview extension of CBM (MVCBM) is proposed to integrate features from multiple ultrasound views of the same patient, improving robustness and performance.
- The model is trained in a semi-supervised manner using both labeled concepts and weakly supervised image-level labels, reducing dependency on costly full annotations.
- A novel architecture enables prediction with incomplete concept sets, allowing clinicians to input only known or uncertain findings.
- The method supports real-time intervention: clinicians can adjust concept values (e.g., 'appendix diameter > 6mm') and observe immediate impact on diagnosis or severity prediction.
- The model is trained and evaluated on a dataset of 579 pediatric patients with 1,709 ultrasound images, combined with clinical and lab data, using AUROC and AUPR as primary metrics.
Experimental results
Research questions
- RQ1Can concept-based machine learning models using ultrasound images achieve high diagnostic performance for pediatric appendicitis while remaining interpretable to clinicians?
- RQ2How can concept bottleneck models be extended to handle multiple ultrasound views and incomplete concept inputs in a clinical setting?
- RQ3Can clinicians meaningfully interact with and modify model predictions through high-level, clinically relevant concepts without compromising performance?
- RQ4How does the performance of the interpretable MVCBM compare to black-box deep learning models on the same dataset?
- RQ5Can the model be deployed in real time with minimal annotation overhead, enabling practical clinical use?
Key findings
- The extended multiview concept bottleneck model (MVCBM) achieved an AUROC of 0.80 and AUPR of 0.92 for diagnosing pediatric appendicitis, matching the performance of black-box neural networks on the same dataset.
- The model enables real-time, interactive prediction where clinicians can modify concept values (e.g., presence of free fluid) and observe immediate changes in diagnosis or severity estimates.
- The model maintains high performance even with incomplete concept sets, demonstrating robustness to missing clinical information.
- The method supports clinician-in-the-loop interpretation: users can trace predictions back to specific ultrasound findings, enhancing trust and transparency.
- A publicly available web demo was deployed at https://papt.inf.ethz.ch/mvcbm, enabling real-time interaction with the model.
- The study highlights limitations such as lack of histological confirmation in conservatively treated patients and the absence of scale information in ultrasound preprocessing, which may affect model robustness.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.