TL;DR

This Conceptual Design Report outlines the deployment of the IsoDAR experiment at Korea's Yemilab, a new underground laboratory, using a compact cyclotron to produce a high-intensity, pure electron antineutrino ($\bar{\nu}_e$) flux via $^8$Li decay at rest. The setup enables precision tests of sterile neutrino oscillations and beyond-Standard Model physics through inverse beta decay and electron neutrino–electron scattering in a 2.5-kton liquid scintillator detector, with detailed plans for site infrastructure, radiation protection, and component installation in a low-background environment.

ABSTRACT

This Conceptual Design Report addresses the site-specific issues associated with the deployment of the IsoDAR experiment at the Yemilab site. IsoDAR@Yemilab pairs the IsoDAR cyclotron-driven $\barν_e$ source with the proposed Liquid Scintillator Counter (LSC) 2.5 kton detector. This document describes the proposed siting: requirements for the caverns to house the cyclotron, beam transport line, and target systems; issues associated with transport and assembly of components on the site; electrical power, cooling and ventilation; as well as issues associated with radiation protection of the environment and staff of Yemilab who will be interfacing with IsoDAR during its operational phases. The onset of construction of the IsoDAR area at Yemilab, in tandem with the release of this design report, represents a key step forward in establishing IsoDAR@Yemilab.

Motivation & Objective

  • To establish a site-specific conceptual design for deploying the IsoDAR experiment at Yemilab, Korea’s new underground laboratory, to enable high-sensitivity neutrino physics.
  • To address engineering and safety challenges related to housing a cyclotron, beam transport, and target systems in a deep underground cavern.
  • To ensure radiation protection and personnel safety during construction and operation, particularly from neutron and gamma activation.
  • To enable precision measurements of electron antineutrino oscillations and elastic scattering, probing sterile neutrinos and new physics beyond the Standard Model.
  • To support the co-location of IsoDAR with other low-background experiments at Yemilab without operational disruption.

Proposed method

  • Utilizes a 60 MeV/amu compact cyclotron accelerating H$_2^+$ ions to produce protons via stripping, which are then directed at a $^9$Be target to generate neutrons.
  • Neutrons are captured in a 99.99% isotopically pure $^7$Li sleeve, producing $^8$Li, which decays with an 839-ms half-life to emit a high-intensity, monoenergetic $\bar{\nu}_e$ flux peaking at ~6 MeV.
  • Employs a liquid scintillator counter (LSC) detector with a fiducial mass of 2.57 ktons located at a baseline of 17 m (range 9.5–25.9 m) to detect $\bar{\nu}_e$ via inverse beta decay ($\bar{\nu}_e + p \to e^+ + n$) and electron scattering.
  • Designs dedicated caverns for the cyclotron, beam transport (MEBT), and target systems, with detailed shielding and ventilation systems to minimize background and radiation exposure.
  • Applies a graded radiation protection strategy, including controlled access zones, real-time monitoring, interlock systems, and PPE protocols, with strict procedures for beam-off access.
  • Incorporates comprehensive environmental controls for air, moisture, and groundwater, with containment and monitoring to prevent radiological contamination.

Experimental results

Research questions

  • RQ1Can a compact cyclotron-based $\bar{\nu}_e$ source be safely and effectively deployed in a deep underground laboratory like Yemilab without compromising other low-background experiments?
  • RQ2What are the key site-specific engineering and shielding requirements for housing the IsoDAR accelerator, transport, and target systems in a limestone-based underground cavern?
  • RQ3How can radiation protection be optimized for personnel during construction and operation, particularly from short-lived activation products and neutron/gamma fields?
  • RQ4What are the dominant sources of long-term rock activation, and how can shielding be designed to minimize environmental and personnel exposure?
  • RQ5Can the required 2.5-kton liquid scintillator detector be effectively coupled to the IsoDAR source to achieve the sensitivity needed for sterile neutrino searches and precision electroweak measurements?

Key findings

  • The IsoDAR@Yemilab experiment is technically feasible, with a projected 5-year runtime and an annual $\bar{\nu}_e$ flux of $1.15 \times 10^{23}$, enabling high-statistics measurements.
  • The experiment is expected to produce approximately $1.9 \times 10^6$ inverse beta decay events and 8,000 electron neutrino–electron elastic scattering events with optimized cuts.
  • The cyclotron and target systems are designed to operate at 80% duty factor, with a proton-on-target rate of $1.97 \times 10^{24}$ per year, ensuring a high-intensity $\bar{\nu}_e$ source.
  • Shielding calculations show that neutron and gamma radiation levels can be effectively contained, with the cyclotron vault and target area designated as high-level controlled zones.
  • Personnel access is strictly regulated via beam-off interlocks, radiation monitoring, and controlled area procedures, with PPE and badge systems required for all entry.
  • Environmental controls, including water collection channels and groundwater monitoring, are implemented to prevent radiological contamination, with negligible risk expected due to the dry limestone environment.