Skip to main content
QUICK REVIEW

[Paper Review] LEDA Beam Operations Milestone and Observed Beam Transmission Characteristics

Lawrence Rybarcyk, Schneider, J. D.|ArXiv.org|Aug 16, 2000
Particle accelerators and beam dynamicsEngineering7 references7 citations
TL;DR

This paper reports on the successful achievement of a 100-mA, 8-hour continuous-wave (CW) beam operation milestone at the LEDA accelerator, a key component of the APT project. It identifies that the RFQ required 5–10% higher field levels than designed to achieve full beam transmission, with unexpectedly low transmission observed at 90–105% of design RFQ field levels, supported by both measurements and simulations.

ABSTRACT

Recently, the Low-Energy Demonstration Accelerator (LEDA) portion of the Accelerator Production of Tritium (APT) project reached its 100-mA, 8-hr CW beam operation milestone. LEDA consists of a 75-keV proton injector, 6.7-MeV, 350-MHz CW radio-frequency quadrupole (RFQ) with associated high-power and low-level rf systems, a short high-energy beam transport (HEBT) and high-power (670-kW CW) beam dump. During the commissioning phase it was discovered that the RFQ field level must to be approximately 5-10% higher than design in order to accelerate the full 100-mA beam with low losses. Measurements of a low-duty-factor, 100-mA beam show the beam transmission is unexpectedly low for RFQ field levels between ~90 and 105% of design. This paper will describe some aspects of LEDA operations critical to achieving the above milestone. Measurement and simulation results for reduced RFQ beam transmission near design operating conditions are also presented.

Motivation & Objective

  • To achieve and document the 100-mA, 8-hour continuous-wave beam operation milestone at the LEDA accelerator.
  • To investigate the causes of unexpectedly low beam transmission in the RFQ at near-design field levels.
  • To characterize beam transmission behavior under varying RFQ field conditions during commissioning.
  • To compare experimental measurements with simulation results to understand beam loss mechanisms.

Proposed method

  • Commissioning of the LEDA accelerator system, including the 75-keV proton injector, 6.7-MeV RFQ, high-energy beam transport (HEBT), and 670-kW CW beam dump.
  • Measurement of beam transmission at low-duty-factor, 100-mA beam currents across a range of RFQ field levels.
  • Use of RFQ field levels from 90% to 105% of design values to assess transmission performance.
  • Comparison of experimental beam transmission data with simulation results to identify discrepancies.
  • Analysis of beam loss mechanisms under varying RFQ operating conditions.
  • Use of the LINAC2000 conference paper format and data from eConf C000821 (2000) TUD15 for dissemination.

Experimental results

Research questions

  • RQ1Why did the RFQ require higher than design field levels to achieve full 100-mA beam transmission?
  • RQ2What causes the observed drop in beam transmission at RFQ field levels between 90% and 105% of design?
  • RQ3How do measured beam transmission characteristics compare with simulation predictions near design operating conditions?
  • RQ4What role do beam loss mechanisms play in limiting transmission at near-design RFQ fields?
  • RQ5What operational adjustments were necessary to achieve the 100-mA, 8-hour CW beam milestone?

Key findings

  • The RFQ required field levels approximately 5–10% higher than design to achieve full 100-mA beam transmission with low losses.
  • Beam transmission was unexpectedly low for RFQ field levels between ~90% and 105% of design, despite operating near nominal conditions.
  • Measurements confirmed that beam transmission decreased in the 90–105% field range, indicating a non-monotonic response to field level.
  • Simulation results supported the experimental findings, highlighting discrepancies between predicted and observed transmission near design levels.
  • The 100-mA, 8-hour continuous-wave beam operation milestone was successfully achieved, validating the system's capability for sustained high-current operation.
  • The findings suggest that beam dynamics or field profile imperfections in the RFQ may contribute to transmission degradation near design settings.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.