Skip to main content
QUICK REVIEW

[Paper Review] Measurement-conditioned Denoising Diffusion Probabilistic Model for Under-sampled Medical Image Reconstruction

Yutong Xie, Quanzheng Li|arXiv (Cornell University)|Mar 5, 2022
Medical Imaging Techniques and ApplicationsMedicine10 citations
TL;DR

This paper proposes Measurement-conditioned Denoising Diffusion Probabilistic Model (MC-DDPM), a novel method for under-sampled medical image reconstruction that operates directly in the measurement domain (e.g., k-space in MRI) and conditions the diffusion process on the under-sampling mask. By defining the diffusion and reverse processes in the measurement space, MC-DDPM inherently enforces data consistency and enables uncertainty quantification through multiple reconstructions, outperforming state-of-the-art methods in both qualitative and quantitative metrics on accelerated MRI datasets.

ABSTRACT

We propose a novel and unified method, measurement-conditioned denoising diffusion probabilistic model (MC-DDPM), for under-sampled medical image reconstruction based on DDPM. Different from previous works, MC-DDPM is defined in measurement domain (e.g. k-space in MRI reconstruction) and conditioned on under-sampling mask. We apply this method to accelerate MRI reconstruction and the experimental results show excellent performance, outperforming full supervision baseline and the state-of-the-art score-based reconstruction method. Due to its generative nature, MC-DDPM can also quantify the uncertainty of reconstruction. Our code is available on github.

Motivation & Objective

  • To address the challenge of under-sampled medical image reconstruction, particularly in MRI, where accelerated acquisition reduces scan time but degrades image quality.
  • To develop a unified generative framework that naturally incorporates data consistency constraints without requiring post-processing.
  • To enable uncertainty quantification in image reconstruction by generating multiple plausible reconstructions from the same measurements.
  • To improve reconstruction quality beyond supervised baselines and score-based generative models in under-sampled imaging scenarios.

Proposed method

  • The method defines the diffusion process in the measurement domain (e.g., k-space) rather than the image domain, enabling direct modeling of under-sampled data.
  • It conditions the reverse diffusion process on the under-sampling mask, ensuring that generated samples are consistent with the acquired measurements by design.
  • The model uses a denoising diffusion probabilistic framework with learned Gaussian transitions, where noise is gradually removed from the measurement space to reconstruct the image.
  • The reverse process is trained to generate the non-sampled k-space from noise, conditioned on the under-sampling pattern, thus embedding data consistency into the model architecture.
  • Multiple reconstructions are sampled from the same measurement, enabling uncertainty estimation via variance across samples.
  • The method is trained end-to-end using a variational inference objective that minimizes the reverse KL divergence between the true and model posterior.

Experimental results

Research questions

  • RQ1Can a diffusion model conditioned on the under-sampling mask in the measurement domain achieve better reconstruction quality than existing methods?
  • RQ2Does conditioning the diffusion process directly on the measurement space naturally enforce data consistency and eliminate the need for external data consistency layers?
  • RQ3Can the generative nature of the model provide meaningful uncertainty estimates through multiple reconstructions of the same under-sampled data?
  • RQ4How does the performance of MC-DDPM compare to supervised learning baselines and score-based generative models in accelerated MRI reconstruction?

Key findings

  • MC-DDPM outperforms the U-Net baseline and the state-of-the-art score-based method from Chung et al. (2021) by 3.68 dB in PSNR and 0.079 in SSIM at 4× acceleration on the PD dataset.
  • At 8× acceleration, MC-DDPM achieves a 3.97 dB improvement in PSNR and a 0.117 improvement in SSIM over U-Net, surpassing the method of Chung et al. (2021).
  • The uncertainty map, computed as the pixel-wise standard deviation across 20 samples, increases with higher acceleration factors, reflecting growing reconstruction ambiguity.
  • Even with only 250 sampling steps, the PSNR remains close to the full 1000-step baseline, indicating robustness to reduced inference time.
  • Increasing the number of samples improves the mean reconstruction quality, with convergence observed around 20 samples, suggesting a practical trade-off between quality and efficiency.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.