TL;DR

This review synthesizes deep learning-based medical image synthesis methods for inter- and intra-modality imaging, highlighting their clinical utility in radiation oncology and radiology. It demonstrates that deep learning outperforms conventional methods in generating realistic, high-fidelity synthetic images with fast inference, though challenges remain in robustness across diverse anatomies, scanners, and data distributions.

ABSTRACT

This paper reviewed the deep learning-based studies for medical imaging synthesis and its clinical application. Specifically, we summarized the recent developments of deep learning-based methods in inter- and intra-modality image synthesis by listing and highlighting the proposed methods, study designs and reported performances with related clinical applications on representative studies. The challenges among the reviewed studies were summarized in the discussion part.

Motivation & Objective

  • To systematically review deep learning-based methods for medical image synthesis across multiple imaging modalities and protocols.
  • To evaluate the performance and clinical applicability of these methods in radiation oncology and radiology workflows.
  • To identify key challenges in model generalization, data diversity, and clinical deployment.
  • To compare deep learning approaches with conventional model-based methods in terms of performance and practicality.
  • To highlight future research directions for robust, multi-center, and clinically deployable image synthesis systems.

Proposed method

  • The study conducted a systematic literature search on PubMed using keywords related to image synthesis, deep learning, and medical imaging modalities (CT, MRI, PET, etc.) up to February 2020.
  • Peer-reviewed journal articles were manually screened, and additional studies were identified via citation chasing, resulting in 111 included articles.
  • Studies were categorized based on deep learning architecture (e.g., U-Net, CycleGAN), imaging modality pairs, and application type (inter- vs. intra-modality synthesis).
  • Performance metrics such as mean absolute error (MAE), structural similarity (SSIM), and visual quality were used to compare methods.
  • The review evaluated model generalization across different scanners, patient populations, and imaging protocols, emphasizing data representativeness.
  • A framework was proposed to assess clinical readiness, including quality assurance procedures for synthetic image validation.

Experimental results

Research questions

  • RQ1How do deep learning-based image synthesis methods compare to conventional model-based methods in image quality and clinical utility?
  • RQ2What are the key deep learning architectures and training strategies that enable high-fidelity inter- and intra-modality image synthesis?
  • RQ3To what extent do model performance and robustness vary across diverse patient anatomies, implants, and scanner vendors?
  • RQ4How do paired versus unpaired training data affect the performance and feasibility of deep learning-based synthesis?
  • RQ5What are the major challenges in deploying these models into clinical workflows, and how can they be addressed?

Key findings

  • Deep learning-based methods significantly outperform conventional model-based approaches in generating realistic synthetic images with lower mean absolute error (MAE) and higher structural similarity (SSIM).
  • 3D U-Net models achieved better accuracy in bone region reconstruction than 2D models, though they require more training data and computational resources.
  • Unpaired generative models like CycleGAN reduce dependency on pixel-wise correspondence, enabling larger-scale dataset utilization for training.
  • Model performance degrades when inputs deviate from training distribution, especially in cases with implants (e.g., hip prostheses) or extreme anatomical variations.
  • Most studies used single-institution, single-scanner datasets, limiting generalizability; multi-center validation with leave-one-center-out strategies is needed.
  • Clinical deployment requires robust quality assurance procedures to monitor model consistency and synthetic image quality across new patient cases and system updates.