Skip to main content
QUICK REVIEW

[Paper Review] Meeting Tight Frequency Requirement of Rounded Damped Detuned Structure

T. Higo, Funahashi, Y.|ArXiv.org|Aug 18, 2000
Structural Engineering and Vibration AnalysisEngineering4 citations
TL;DR

This paper presents a method to achieve stringent frequency control in Rounded Damped Detuned Structures (RDDS) for linear collider applications using high-precision diamond turning and a feed-forward correction on the cell diameter parameter '2b'. The approach achieves sub-MHz accuracy in accelerating mode frequency (0.1 MHz RMS systematic error) and 0.6 MHz RMS in dipole mode frequency spread, meeting critical requirements for low wakefield and phase stability.

ABSTRACT

Following successful design and fabrication of damped detuned structures, the R&D for the accelerating structures of the NLC/JLC linear collider project proceeded to studies of Rounded Damped Detuned Structure with curved cross section of the cavity shape for increased shunt impedance. The important features of the structure are the accurately tuned accelerating mode frequency and the distribution of the first dipole modes smooth and close to the design distribution. These requirements were met based on the high-accuracy diamond turning with its capability to realize the periphery tolerance of two microns. The lowest dipole mode frequencies scattered by 0.6 MHz RMS. The error in the accelerating mode frequency averaged over a structure was 0.1 MHz by applying a feed-forward method.

Motivation & Objective

  • To meet the tight frequency requirements for the accelerating mode and first dipole modes in Rounded Damped Detuned Structures (RDDS) for the NLC/JLC linear collider.
  • To ensure the accelerating mode frequency error remains below 0.1 MHz RMS to limit integrated phase slip to 5 degrees.
  • To maintain the first dipole mode frequency distribution smooth and within 3 MHz RMS of the design distribution.
  • To validate that high-accuracy diamond turning with periphery tolerance of ±2 µm can achieve the required frequency stability.
  • To develop and apply a feed-forward correction method on the cell diameter '2b' to compensate for systematic frequency drifts during fabrication.

Proposed method

  • High-precision diamond turning with periphery tolerance of ±2 µm was used to machine RDDS disks, ensuring mechanical accuracy.
  • The critical dimension '2b' (cell diameter) was measured via 3D coordinate measuring machine and corrected using a feed-forward method to control accelerating mode frequency.
  • Frequency control was achieved by specifying precise 3D geometries at key points and smoothly interpolating intermediate dimensions.
  • A 3rd-order polynomial fit was applied to the first dipole mode (Fd1π) frequency distribution to assess smoothness and deviation from design.
  • RF measurements were performed on single-disk stacks using flat plates to excite zero and π modes, enabling accurate frequency calibration.
  • Systematic errors in '2b' were corrected in real time during fabrication to maintain frequency stability across the structure.

Experimental results

Research questions

  • RQ1Can high-precision diamond turning with ±2 µm periphery tolerance achieve the required frequency stability for RDDS?
  • RQ2How can systematic frequency errors in the accelerating mode be suppressed to below 0.1 MHz RMS?
  • RQ3What is the achievable spread in first dipole mode frequencies, and does it remain within the 3 MHz RMS tolerance?
  • RQ4Can a feed-forward correction on '2b' effectively compensate for cumulative phase errors along the structure?
  • RQ5Is the frequency distribution of the first dipole modes smooth and close to the design distribution?

Key findings

  • The random frequency error in the accelerating mode was measured at 0.1 MHz RMS after feed-forward correction, well below the 3 MHz tolerance.
  • The random error in the first dipole mode frequencies was 0.6 MHz RMS, significantly below the 3 MHz threshold.
  • The integrated phase slip along the 6-disk structure was kept within 5 degrees, equivalent to an average frequency error of 0.1 MHz.
  • The frequency distribution of the first dipole modes remained smooth and within 3 MHz of the design distribution, as confirmed by 3rd-order polynomial fitting.
  • The mechanical precision of the diamond turning process was verified with OD measurements within ±1 µm, indicating ±1 µm tolerance in '2b'.
  • The vacuum pumping disks showed a 0.8 MHz higher frequency than other disks, though the cause remains unexplained.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.