Skip to main content
QUICK REVIEW

[Paper Review] Motion Corrected Multishot MRI Reconstruction Using Generative Networks with Sensitivity Encoding

Muhammad Usman, Farooq, Muhammad Umar|arXiv (Cornell University)|Feb 20, 2019
Advanced MRI Techniques and ApplicationsMedicine48 references10 citations
TL;DR

This paper proposes a GAN-enhanced conjugate gradient SENSE (CG-SENSE) framework for retrospective motion correction in multishot MRI, where motion-corrupted k-space data are first reconstructed via CG-SENSE and then refined by a generative adversarial network to remove artifacts. The method achieves state-of-the-art image quality with a 100x reduction in computational time compared to iterative approaches, demonstrating robustness across varying motion levels, shot counts, and encoding trajectories.

ABSTRACT

Multishot Magnetic Resonance Imaging (MRI) is a promising imaging modality that can produce a high-resolution image with relatively less data acquisition time. The downside of multishot MRI is that it is very sensitive to subject motion and even small amounts of motion during the scan can produce artifacts in the final MR image that may cause misdiagnosis. Numerous efforts have been made to address this issue; however, all of these proposals are limited in terms of how much motion they can correct and the required computational time. In this paper, we propose a novel generative networks based conjugate gradient SENSE (CG-SENSE) reconstruction framework for motion correction in multishot MRI. The proposed framework first employs CG-SENSE reconstruction to produce the motion-corrupted image and then a generative adversarial network (GAN) is used to correct the motion artifacts. The proposed method has been rigorously evaluated on synthetically corrupted data on varying degrees of motion, numbers of shots, and encoding trajectories. Our analyses (both quantitative as well as qualitative/visual analysis) establishes that the proposed method significantly robust and outperforms state-of-the-art motion correction techniques and also reduces severalfold of computational times.

Motivation & Objective

  • Address the challenge of motion artifacts in multishot MRI, which degrade image quality and risk misdiagnosis.
  • Overcome the limitations of iterative motion correction methods, which are computationally expensive and sensitive to motion magnitude and encoding schemes.
  • Develop a parameter-free, end-to-end motion correction framework that does not require motion estimation during acquisition or reconstruction.
  • Enable robust performance across diverse multishot MRI parameters, including varying degrees of motion, number of shots, and encoding trajectories.
  • Reduce reconstruction time significantly to support clinical deployment of high-resolution multishot MRI

Proposed method

  • First apply conjugate gradient SENSE (CG-SENSE) to reconstruct motion-corrupted images from k-space data, leveraging sensitivity encoding for parallel imaging.
  • Feed the reconstructed artifact-laden image into a generative adversarial network (GAN) that learns to map motion-degraded images to artifact-free, high-quality MR images.
  • Train the GAN using adversarial loss to enforce perceptual consistency and high-order image structure, improving realism and artifact suppression.
  • Decouple motion correction from the reconstruction process: CG-SENSE performs full k-space reconstruction first, followed by GAN-based refinement.
  • Use a discriminator network to distinguish real from generated images, enabling the generator to learn realistic image priors without explicit motion modeling.
  • The framework is agnostic to encoding trajectory and number of shots, enabling generalization across different multishot MRI protocols.

Experimental results

Research questions

  • RQ1Can a GAN-based framework effectively correct motion artifacts in multishot MRI without requiring prior motion estimation during acquisition or reconstruction?
  • RQ2How does the proposed method compare to state-of-the-art iterative motion correction techniques in terms of image quality and computational efficiency?
  • RQ3Does the performance of the proposed method remain robust across varying degrees of rigid head motion, number of shots, and encoding trajectories?
  • RQ4Can the GAN-based correction step be made independent of motion magnitude and reconstruction complexity, enabling consistent inference time regardless of input parameters?

Key findings

  • The proposed method reduced computational time by over 100x compared to the state-of-the-art iterative method [21], with a consistent correction time of 0.28 seconds regardless of motion level.
  • For 128 shots, the proposed method required only 1.40 seconds total reconstruction time, compared to 89.19 seconds for the iterative method [21], demonstrating significant speedup.
  • At 14° of motion, the iterative method took 152.03 seconds, while the proposed method maintained a constant 0.28-second correction time, highlighting its scalability.
  • The GAN-based correction step was independent of motion magnitude, ensuring stable performance across 5° to 14° of motion, unlike iterative methods that scale poorly with motion.
  • Visual and quantitative evaluations confirmed that the proposed method outperformed existing techniques in artifact suppression and structural similarity (SSIM) across all tested parameters.
  • The framework demonstrated robustness to changes in encoding trajectories and shot counts, maintaining high image quality without retraining or architectural changes.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.