TL;DR

This paper proposes a multi-feature semi-supervised learning (SSL) framework for COVID-19 diagnosis from chest X-ray (CXR) images, integrating local-phase features (LwPA, LPE, ELEA) into a multi-channel input for improved representation learning. Using only 7.06% labeled and 16.48% unlabeled data for training, the method achieves 93.61% mean accuracy on a large-scale 70.93% test set, outperforming both supervised and prior SSL methods.

ABSTRACT

Computed tomography (CT) and chest X-ray (CXR) have been the two dominant imaging modalities deployed for improved management of Coronavirus disease 2019 (COVID-19). Due to faster imaging, less radiation exposure, and being cost-effective CXR is preferred over CT. However, the interpretation of CXR images, compared to CT, is more challenging due to low image resolution and COVID-19 image features being similar to regular pneumonia. Computer-aided diagnosis via deep learning has been investigated to help mitigate these problems and help clinicians during the decision-making process. The requirement for a large amount of labeled data is one of the major problems of deep learning methods when deployed in the medical domain. To provide a solution to this, in this work, we propose a semi-supervised learning (SSL) approach using minimal data for training. We integrate local-phase CXR image features into a multi-feature convolutional neural network architecture where the training of SSL method is obtained with a teacher/student paradigm. Quantitative evaluation is performed on 8,851 normal (healthy), 6,045 pneumonia, and 3,795 COVID-19 CXR scans. By only using 7.06% labeled and 16.48% unlabeled data for training, 5.53% for validation, our method achieves 93.61\% mean accuracy on a large-scale (70.93%) test data. We provide comparison results against fully supervised and SSL methods. Code: https://github.com/endiqq/Multi-Feature-Semi-Supervised-Learning-for-COVID-19-CXR-Images

Motivation & Objective

  • Address the challenge of limited labeled medical data in deep learning for COVID-19 diagnosis.
  • Improve classification performance on CXR images by leveraging local-phase image features to enhance representation learning.
  • Develop a semi-supervised learning framework that reduces reliance on large amounts of labeled data in medical imaging.
  • Evaluate the method on a large-scale, real-world CXR dataset with diverse patient populations.

Proposed method

  • Extract three local-phase features—local weighted mean phase angle (LwPA), LwPA-weighted local phase energy (LPE), and enhanced local energy attenuation (ELEA)—using bandpass quadrature filters and L1 regularization.
  • Combine the three local-phase features into a three-channel multi-feature (MF) image input for the neural network.
  • Implement a teacher/student semi-supervised learning pipeline where the teacher model is trained on labeled data and used to generate pseudo-labels for unlabeled data.
  • Apply consistency regularization and confidence-based filtering to refine pseudo-labeled data and improve student model generalization.
  • Use a multi-stream convolutional neural network (CNN) architecture with shared weights to process both original CXR and multi-feature MF images.
  • Optimize the student model using a combination of labeled data and high-confidence pseudo-labeled data, with early stopping and learning rate decay.

Experimental results

Research questions

  • RQ1Can local-phase features improve the performance of semi-supervised learning models in classifying COVID-19 from CXR images?
  • RQ2How does the integration of multi-feature representations (original CXR + local-phase features) affect model generalization with minimal labeled data?
  • RQ3Does the proposed teacher/student SSL framework outperform existing SSL and fully supervised baselines when training data is severely limited?
  • RQ4How robust is the model to distribution shifts across different patient populations and imaging conditions?

Key findings

  • The proposed MF-TS model achieves 93.61% mean accuracy on a large-scale test set (70.93% of total data), using only 7.06% labeled and 16.48% unlabeled data for training.
  • With just 10% of labeled data (2.35% of full dataset), the MF-TS model achieves 92.43% mean accuracy on Test-1, significantly outperforming ResNet50 (86.46%) and other SSL baselines.
  • The MF-TS model shows superior stability across datasets, with only a 1.69% average accuracy drop between Test-1 and Test-2, compared to 8.58% for pseudo-labeling.
  • The multi-feature approach (MF-TS) improves performance over the baseline CXR-TS (Billion-Scale) by 1.22% on Test-2 and 1.18% on Test-1, demonstrating the benefit of feature fusion.
  • The ablation study confirms that local-phase features significantly enhance model performance, with MF-TS outperforming single-feature variants like Enh-TS and MF-T.
  • The method achieves state-of-the-art performance on the largest reported SSL evaluation for COVID-19 CXR classification, using only minimal labeled data.