[Paper Review] Multi-pass guided atomic Sagnac interferometer for high-performance rotation sensing
This paper proposes a multi-pass guided atomic Sagnac interferometer using a Bose-Einstein condensate on a chip to achieve high-precision rotation sensing. By mitigating coherence losses from guide roughness and phase diffusion due to atom-atom interactions, the scheme enables sensitivities of 45 nrad s⁻¹ Hz⁻¹ ⁄²—comparable to free-space interferometers—while offering a 2–4 order-of-magnitude improvement in sensitivity-to-size ratio, with potential for 4–6 orders of magnitude better performance using thermal atoms.
Matter-wave interferometry with atoms propagating in a guiding potential is expected to provide compact, scalable and precise inertial sensing. However, a rotation sensing device based on the Sagnac effect with atoms guided in a ring has not yet been implemented despite continuous efforts during the last two decades. Here we discuss some intrinsic effects that limit the coherence in such a device and propose a scheme that overcomes these limitations and enables a multi-pass guiding Sagnac interferometer with a Bose-Einstein condensate (BEC) on a chip in a ring potential. We analyze crucial dephasing effects: potential roughness, phase diffusion due to atom-atom interactions and number uncertainty, and phase fluctuations. Owing to the recent progress in achieving high momentum beam splitting, creating smooth guides, and manipulating the matter-wavepacket propagation, guided interferometry can be implemented within the coherence time allowed by phase diffusion. Despite the lower particle flux in a guided Sagnac ring and the miniaturization of the interferometer, the estimated sensitivity, for reasonable and practical realizations of an atom chip-based gyroscope, is comparable to that of free-space interferometers, reaching 45 nrads^{-1}Hz^{-1/2}. A significant improvement over state-of-the-art free-space gyrocope sensitivities can be envisioned by using thermal atoms instead of a BEC, whereby the interferometer can be operated in a continuous fashion with the coherence limited by the scattering rate of the atoms with the background gas. Taking into account the sensitivity times length of the interferometer as the figure of merit which takes into account compactness, our configuration is expected to deliver a potential improvement of 2-4 orders of magnitude over state-of-the-art free-space gyroscopes for a BEC, and 4-6 orders of magnitude for thermal atoms.
Motivation & Objective
- To overcome fundamental coherence limitations in guided atomic Sagnac interferometers, particularly phase diffusion from atom-atom interactions and guide roughness.
- To enable high-sensitivity rotation sensing using a compact, chip-based system by extending coherence time through optimized potential design.
- To demonstrate that guided interferometers can match or exceed the performance of large-scale free-space atomic gyroscopes in sensitivity per unit size.
- To explore the feasibility of continuous operation using thermal atoms to further enhance sensitivity beyond BEC-based systems.
Proposed method
- Utilizes a ring-shaped potential on an atom chip to guide a Bose-Einstein condensate (BEC) in a closed loop for Sagnac interferometry.
- Employs time-averaged adiabatic potentials (TAAP) or static magnetic fields to create smooth, low-roughness guides that minimize dephasing.
- Applies the time-dependent Thomas-Fermi approximation to model and mitigate phase diffusion caused by transverse confinement and atom-atom interactions.
- Implements high-momentum beam splitters (up to ~60ℏk) to enable multiple passes around the ring, enhancing signal accumulation.
- Considers both BEC and thermal atom configurations, with the latter allowing continuous operation limited only by background gas scattering.
- Evaluates sensitivity using the figure of merit of sensitivity × length, favoring compact, high-performance designs.
Experimental results
Research questions
- RQ1What are the dominant dephasing mechanisms in a guided atomic Sagnac interferometer, and can they be mitigated to enable long coherence times?
- RQ2How do atom-atom interactions in a confined ring guide affect phase diffusion, and can this be modeled and reduced using time-dependent potential shaping?
- RQ3Can a multi-pass guided interferometer achieve sensitivity comparable to free-space atomic gyroscopes despite lower atomic flux?
- RQ4What performance gains are possible by using thermal atoms instead of a BEC in a continuous operation scheme?
- RQ5To what extent can miniaturized, chip-based guided interferometers outperform existing large-scale free-space or ring-laser gyroscopes in sensitivity per unit size?
Key findings
- The proposed multi-pass guided Sagnac interferometer achieves a sensitivity of 45 nrad s⁻¹ Hz⁻¹ ⁄² using a BEC on a chip, matching state-of-the-art free-space interferometers.
- For a 50 mm radius guide with ~60ℏk momentum transfer, the system can achieve a sensitivity of 5 prad s⁻¹ after 10 s—surpassing a five-story building-scale ring laser gyroscope (10 prad s⁻¹ after 120 s).
- Using thermal atoms with a flux of 10⁷ s⁻¹ and 1000 turns, the sensitivity reaches 1 prad s⁻¹ Hz⁻¹ ⁄², representing a 4–6 order-of-magnitude improvement over current thermal-beam gyroscopes.
- The sensitivity-to-size figure of merit shows a 2–4 order-of-magnitude improvement over state-of-the-art free-space gyroscopes using BECs, and 4–6 orders using thermal atoms.
- Phase diffusion due to atom-atom interactions is significantly reduced in the time-dependent Thomas-Fermi model when transverse kinetic energy is included, suggesting further performance gains with refined modeling.
- Smooth, low-roughness guides—achievable via time-averaged potentials or static fields—can suppress dephasing and enable long coherence times necessary for multi-pass operation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.