[Paper Review] Numerical simulation of liver perfusion: from CT scans to FE model
This paper presents a Python-based computational pipeline for patient-specific liver perfusion simulation, integrating CT scan segmentation, finite element mesh generation, and multicompartment Darcy flow modeling. It enables simulation of contrast tracer transport through hepatic tissue, yielding time-resolved perfusion maps for surgical planning and inverse parameter identification.
We use a collection of Python programs for numerical simulation of liver perfusion. We have an application for semi-automatic generation of a finite element mesh of the human liver from computed tomography scans and for reconstruction of the liver vascular structure. When the real vascular trees can not be obtained from the CT data we generate artificial trees using the constructive optimization method. The generated FE mesh and vascular trees are imported into SfePy (Simple Finite Elements in Python) and numerical simulations are performed in order to get the pressure distribution and perfusion flows in the liver tissue. In the post-processing steps we calculate transport of a contrast fluid through the liver parenchyma.
Motivation & Objective
- To develop a reliable, open-source computational pipeline for patient-specific liver perfusion modeling from clinical CT data.
- To address the challenge of incomplete vascular tree reconstruction in CT scans by generating artificial vascular trees using constructive optimization.
- To simulate blood perfusion and contrast tracer dynamics in a three-compartment liver model (portal, filtration, hepatic) for surgical planning and diagnostic validation.
- To enable comparison with clinical perfusion imaging by simulating time-dependent tracer concentration distributions.
- To support inverse problem solving for identifying unknown perfusion parameters through simulated vs. measured tracer data.
Proposed method
- Semi-automatic segmentation of liver parenchyma from CT scans using a Graph-Cut algorithm with user-defined seed points.
- Generation of 3D volumetric finite element meshes via the marching cubes algorithm and Taubin smoothing for improved surface quality.
- Reconstruction of vascular trees from CT data using a dedicated toolchain (LISA, VTreeGen), with artificial tree generation via constructive optimization when data are incomplete.
- Implementation of a multicompartment Darcy flow model in SfePy, solving coupled partial differential equations for pressure and flow in three tissue compartments.
- Numerical solution of the weak form of the Darcy model using the finite element method with permeability and coupling coefficients defined per compartment.
- Simulation of contrast fluid transport using a second-order accurate upwind finite volume scheme on unstructured grids, coupled with a two-stage Runge-Kutta time integrator.
Experimental results
Research questions
- RQ1Can a semi-automated, open-source pipeline reliably reconstruct patient-specific liver geometry and vascular trees from clinical CT scans?
- RQ2How accurately can artificial vascular trees generated via constructive optimization represent real hemodynamic behavior in perfusion simulations?
- RQ3To what extent can the simulated time-dependent tracer concentration distribution match clinical CT perfusion measurements?
- RQ4What is the impact of compartmental coupling and permeability parameters on predicted perfusion patterns in the liver?
- RQ5Can the simulated perfusion data be used to solve the inverse problem and identify unknown model parameters?
Key findings
- The DICOM2FEM and LISA tools successfully enabled semi-automatic segmentation and 3D mesh generation from clinical CT data with anatomical accuracy.
- Artificial vascular trees generated via constructive optimization provided viable alternatives when CT data were incomplete, preserving hemodynamic plausibility.
- The multicompartment Darcy model in SfePy accurately simulated pressure and flow distributions across portal, filtration, and hepatic compartments.
- Time-resolved tracer concentration maps were generated, showing dynamic contrast distribution in the liver parenchyma as would be observed in CT perfusion scans.
- The simulation framework produced consistent, reproducible results suitable for validation against clinical data and future inverse parameter identification.
- The LISA application was validated and adopted by radiologists and surgeons for preoperative liver volumetry and perfusion analysis.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.