Skip to main content
QUICK REVIEW

[Paper Review] OCMR (v1.0)--Open-Access Multi-Coil k-Space Dataset for Cardiovascular Magnetic Resonance Imaging

Chong Chen, Yingmin Liu|arXiv (Cornell University)|Aug 8, 2020
Advanced MRI Techniques and ApplicationsMedicine28 references29 citations
TL;DR

OCMR (v1.0) is an open-access, multi-coil k-space dataset comprising 53 fully sampled and 212 prospectively undersampled cardiac cine MRI scans, designed to enable objective evaluation and comparison of accelerated cardiovascular MRI reconstruction techniques. The dataset supports both quantitative and qualitative assessment of image reconstruction methods, particularly for free-breathing, accelerated imaging, and is accessible via MATLAB and Python interfaces with ISMRMRD-compliant HDF5 formatting.

ABSTRACT

Cardiovascular MRI (CMR) is a non-invasive imaging modality that provides excellent soft-tissue contrast without the use of ionizing radiation. Physiological motions and limited speed of MRI data acquisition necessitate development of accelerated methods, which typically rely on undersampling. Recovering diagnostic quality CMR images from highly undersampled data has been an active area of research. Recently, several data acquisition and processing methods have been proposed to accelerate CMR. The availability of data to objectively evaluate and compare different reconstruction methods could expedite innovation and promote clinical translation of these methods. In this work, we introduce an open-access dataset, called OCMR, that provides multi-coil k-space data from 53 fully sampled and 212 prospectively undersampled cardiac cine series.

Motivation & Objective

  • To address the lack of publicly available, standardized datasets for evaluating and comparing accelerated cardiovascular MRI reconstruction methods.
  • To support the clinical translation of advanced reconstruction techniques, especially those based on machine learning, by providing a shared data platform.
  • To enable both quantitative comparison (using fully sampled scans) and qualitative evaluation (using free-breathing, prospectively undersampled scans) of reconstruction algorithms.
  • To provide de-identified, high-fidelity k-space data across diverse cardiac cine acquisitions for reproducible research.
  • To establish a foundation for future expansion to include other CMR applications such as 2D phase-contrast MRI.

Proposed method

  • The dataset collects multi-coil k-space data from 53 fully sampled and 212 prospectively undersampled cardiac cine MRI scans using clinical MRI scanners.
  • Data are stored in ISMRMRD-compliant HDF5 format with a nine-dimensional array structure: [kx, ky, kz, coil, phase, set, slice, rep, avg].
  • A MATLAB wrapper (read_ocmr.m) and a Python interface (read_ocmr.py) are provided for seamless data loading and parameter extraction.
  • The dataset includes acquisition parameters in a structure (param), such as FOV, temporal resolution, flip angle, and sequence type, enabling accurate reconstruction and analysis.
  • Pre-processing steps such as 1D FFT along the readout direction and central 50% cropping are recommended to correct for 2x oversampling in the readout dimension.
  • All data are de-identified with manual inspection to ensure removal of protected health information and facial features.

Experimental results

Research questions

  • RQ1How well can existing and novel image reconstruction algorithms perform on highly undersampled, free-breathing cardiac cine MRI data?
  • RQ2To what extent can a standardized, open-access k-space dataset improve reproducibility and fairness in evaluating reconstruction methods?
  • RQ3Can the inclusion of both fully sampled and prospectively undersampled data enable both quantitative and qualitative benchmarking of reconstruction techniques?
  • RQ4How do different sampling patterns (e.g., pseudo-random, asymmetric echo) affect reconstruction performance and image quality?
  • RQ5What is the impact of multi-coil data structure and acquisition parameters on the generalizability of machine learning-based reconstruction models?

Key findings

  • OCMR (v1.0) provides 53 fully sampled and 212 prospectively undersampled cardiac cine MRI datasets, all with multi-coil k-space data and de-identified patient information.
  • The dataset is accessible via MATLAB and Python interfaces, with pre-built wrappers for ISMRMRD-compliant HDF5 file reading and parameter extraction.
  • The k-space data are structured across nine dimensions, including spatial encoding, coil elements, temporal frames, and repetition/averaging, enabling detailed reconstruction analysis.
  • Spatial resolution can be calculated from FOV and k-space size using the formula: [FOV(1)/size(kData,1), FOV(2)/size(kData,2), FOV(3)/size(kData,3)].
  • The readout dimension includes a factor of two oversampling, which necessitates pre-processing via 1D FFT and central cropping to restore correct FOV.
  • The dataset is designed to support both quantitative evaluation (using fully sampled data) and qualitative assessment (using undersampled, free-breathing data) of reconstruction methods.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.