[Paper Review] On the influence of Dice loss function in multi-class organ segmentation of abdominal CT using 3D fully convolutional networks
This study investigates the impact of three Dice loss weighting strategies—uniform, simple, and square—on multi-class abdominal organ segmentation using 3D fully convolutional networks (FCNs). It demonstrates that the choice of class-balancing weights and initial learning rate significantly affects segmentation accuracy, with the simple weighting scheme achieving the highest average Dice score (81.0%) at a learning rate of 0.01.
Deep learning-based methods achieved impressive results for the segmentation of medical images. With the development of 3D fully convolutional networks (FCNs), it has become feasible to produce improved results for multi-organ segmentation of 3D computed tomography (CT) images. The results of multi-organ segmentation using deep learning-based methods not only depend on the choice of networks architecture, but also strongly rely on the choice of loss function. In this paper, we present a discussion on the influence of Dice-based loss functions for multi-class organ segmentation using a dataset of abdominal CT volumes. We investigated three different types of weighting the Dice loss functions based on class label frequencies (uniform, simple and square) and evaluate their influence on segmentation accuracies. Furthermore, we compared the influence of different initial learning rates. We achieved average Dice scores of 81.3%, 59.5% and 31.7% for uniform, simple and square types of weighting when the learning rate is 0.001, and 78.2%, 81.0% and 58.5% for each weighting when the learning rate is 0.01. Our experiments indicated a strong relationship between class balancing weights and initial learning rate in training.
Motivation & Objective
- To analyze the influence of different Dice loss weighting schemes on multi-organ segmentation performance in 3D abdominal CT volumes.
- To investigate how initial learning rate affects training convergence and segmentation accuracy when using Dice-based loss functions.
- To determine optimal combinations of loss weighting and learning rate for improved segmentation of diverse abdominal organs with varying voxel frequencies.
- To evaluate the generalization and stability of 3D U-Net models under different loss function configurations without data augmentation.
- To provide empirical guidance on hyperparameter selection for 3D FCNs in multi-class medical image segmentation tasks.
Proposed method
- Employed a 3D U-Net architecture as the backbone network for end-to-end 3D multi-organ segmentation from abdominal CT volumes.
- Implemented three Dice loss weighting strategies: uniform (Wu=1), simple (Ws = N / (L|Rl| + ε)), and square (Wq = N / (L|Rl|² + ε)), where |Rl| is the number of voxels in class l.
- Trained the model using stochastic gradient descent with two initial learning rates: μ = 0.001 and μ = 0.01.
- Used random cropping of 64×64×64 subvolumes from full CT volumes to enable mini-batch training and full-volume inference.
- Evaluated segmentation performance using the Dice similarity coefficient (DSC) on eight abdominal organs.
- Applied ε = 1 to prevent division by zero in the weighting formulations.
Experimental results
Research questions
- RQ1How does uniform, simple, and square weighting of the Dice loss function affect segmentation accuracy across multiple abdominal organs?
- RQ2What is the impact of varying the initial learning rate (0.001 vs. 0.01) on the convergence and performance of Dice-based loss functions?
- RQ3Which combination of loss weighting and learning rate yields the highest average Dice score across all organs?
- RQ4How do class imbalance and voxel frequency influence the effectiveness of different Dice loss weighting schemes?
- RQ5Does the training dynamics (e.g., loss curve behavior) differ significantly between weighting schemes, suggesting different convergence patterns?
Key findings
- At a learning rate of 0.001, the uniform weighting scheme achieved the highest average Dice score (81.3%) across all eight organs.
- With a learning rate of 0.01, the simple weighting scheme outperformed others, achieving an average Dice score of 81.0%, significantly improving performance on artery, portal vein, and pancreas.
- The square weighting scheme showed marked improvement at μ = 0.01, achieving a 58.5% average Dice score, particularly enhancing segmentation of liver, spleen, and stomach.
- The simple weighting scheme saw the largest performance gain from increasing the learning rate—from 59.5% at μ = 0.001 to 81.0% at μ = 0.01.
- Training curves indicated that the uniform weighting model converged by 10,000 iterations, while simple and square schemes showed continued improvement potential beyond 10,000 iterations.
- No strong overfitting was observed despite the absence of data augmentation, suggesting the training dataset was sufficiently large and diverse.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.