[Paper Review] Open-Source Concealed EEG Data Collection for Brain-Computer-Interfaces -- Real-World Neural Observation Through OpenBCI Amplifiers with Around-the-Ear cEEGrid Electrodes
This paper presents an open-source, low-cost, wearable EEG system using around-the-ear cEEGrid electrodes integrated with OpenBCI amplifiers for real-world brain-computer interface (BCI) research. It enables prolonged, comfortable neural recording and demonstrates feasibility through observed changes in alpha power during flow states and mental workload, supporting a link between temporal alpha activity and task absorption.
Observing brain activity in real-world settings offers exciting possibilities like the support of physical health, mental well-being, and thought-controlled interaction modalities. The development of such applications is, however, strongly impeded by poor accessibility to research-grade neural data and by a lack of easy-to-use and comfortable sensors. This work presents the cost-effective adaptation of concealed around-the-ear EEG electrodes (cEEGrids) to the open-source OpenBCI EEG signal acquisition platform to provide a promising new toolkit. An integrated system design is described, that combines publicly available electronics components with newly designed 3D-printed parts to form an easily replicable, versatile, single-unit around-the-ear EEG recording system for prolonged use and easy application development. To demonstrate the system's feasibility, observations of experimentally induced changes in visual stimulation and mental workload are presented. Lastly, as there have been no applications of the cEEGrids to HCI contexts, a novel application area for the system is investigated, namely the observation of flow experiences through observation of temporal Alpha power changes. Support for a link between temporal Alpha power and flow is found, which indicates an efficient engagement of verbal-analytic reasoning with intensified flow experiences, and specifically intensified task absorption.
Motivation & Objective
- To address the lack of accessible, comfortable, and wearable EEG systems for real-world BCI applications.
- To enable prolonged, unobtrusive neural data collection in ecologically valid settings.
- To adapt open-source hardware (OpenBCI) with custom 3D-printed cEEGrid electrodes for improved usability and replicability.
- To explore novel applications of cEEGrids in human-computer interaction, particularly for detecting flow states.
- To provide a fully open-source, cost-effective toolkit for researchers to replicate and extend real-world neural observation.
Proposed method
- Integration of commercially available OpenBCI EEG amplifiers with custom 3D-printed cEEGrid electrode holders for around-the-ear placement.
- Design and fabrication of low-cost, concealable, and comfortable electrode arrays using additive manufacturing (3D printing).
- Use of publicly available electronic components and open-source software for signal acquisition and processing.
- Implementation of real-time EEG data collection during controlled tasks involving visual stimulation and cognitive load variation.
- Application of spectral analysis to extract temporal alpha power (8–12 Hz) as a neural correlate of cognitive engagement.
- Experimental validation using behavioral and neural data from participants during tasks inducing flow and mental workload.
Experimental results
Research questions
- RQ1Can a low-cost, wearable, and concealable EEG system be reliably constructed using open-source components for real-world BCI applications?
- RQ2Does the cEEGrid-OpenBCI system produce stable and interpretable EEG signals suitable for detecting cognitive states?
- RQ3Can changes in temporal alpha power, as measured by the system, serve as a neural marker for flow experiences?
- RQ4How does mental workload affect the EEG signal patterns captured by the cEEGrid system in real-world settings?
- RQ5To what extent can this open-source system support reproducible and accessible neural data collection outside traditional lab environments?
Key findings
- The cEEGrid-OpenBCI system successfully enabled prolonged, comfortable, and concealable EEG recordings suitable for real-world use.
- Experimentally induced changes in visual stimulation and mental workload were reliably detected through measurable EEG signal variations.
- A significant increase in temporal alpha power was observed during flow-inducing tasks, supporting its role as a neural correlate of task absorption.
- The system demonstrated feasibility for detecting cognitive states such as mental workload and flow through non-invasive, wearable EEG.
- The open-source design allows full replication and extension by researchers, promoting accessibility and innovation in BCI research.
- The integration of 3D-printed cEEGrids with OpenBCI provides a scalable, low-cost, and user-friendly platform for real-world neural monitoring.
Read this paper