[Paper Review] Optimizing for periodicity: a model-independent approach to flux crosstalk calibration for superconducting circuits

X. Dai, R. Trappen|arXiv (Cornell University)|Nov 2, 2022
Quantum and electron transport phenomenaPhysics and Astronomy1 citations
TL;DR

This paper proposes a model-independent method to calibrate flux crosstalk in superconducting quantum circuits by exploiting the intrinsic periodic response of these systems to external flux. By optimizing for signal periodicity across each flux channel using compensation parameters from other channels, the method achieves high-fidelity crosstalk calibration without requiring detailed circuit models or high-resolution scans, demonstrating comparable accuracy to prior methods on a flux qubit-based quantum annealing chip with a nearly convex optimization landscape.

ABSTRACT

Flux tunability is an important engineering resource for superconducting circuits. Large-scale quantum computers based on flux-tunable superconducting circuits face the problem of flux crosstalk, which needs to be accurately calibrated to realize high-fidelity quantum operations. Typical calibration methods either assume that circuit elements can be effectively decoupled and simple models can be applied, or require a large amount of data. Such methods become ineffective as the system size increases and circuit interactions become stronger. Here we propose a new method for calibrating flux crosstalk, which is independent of the underlying circuit model. Using the fundamental property that superconducting circuits respond periodically to external fluxes, crosstalk calibration of N flux channels can be treated as N independent optimization problems, with the objective functions being the periodicity of a measured signal depending on the compensation parameters. We demonstrate this method on a small-scale quantum annealing circuit based on superconducting flux qubits, achieving comparable accuracy with previous methods. We also show that the objective function usually has a nearly convex landscape, allowing efficient optimization.

Motivation & Objective

  • To address the challenge of flux crosstalk in large-scale superconducting quantum circuits, which degrades gate fidelity and complicates control.
  • To develop a calibration method that does not rely on simplified circuit models or extensive data scans, which become impractical as system size increases.
  • To leverage the fundamental periodic response of superconducting circuits to external flux as a basis for crosstalk calibration.
  • To enable efficient, automated, and scalable calibration of multiple flux control lines using periodicity as a figure of merit.
  • To demonstrate that the periodicity-based objective function has a nearly convex landscape, enabling robust and efficient optimization.

Proposed method

  • The method treats crosstalk calibration as N independent optimization problems, one for each of N flux channels.
  • For each channel, the objective function is the periodicity of a measured signal as a function of compensation parameters from the other N−1 channels.
  • Periodicity is quantified using a metric based on the power spectrum of the measured signal, favoring signals with dominant peaks at integer multiples of the flux quantum.
  • Optimization is performed using the SPSA algorithm (Simultaneous Perturbation Stochastic Approximation), which efficiently navigates the parameter space with minimal measurements.
  • The approach is model-independent: it does not require knowledge of the underlying circuit Hamiltonian or coupling matrix.
  • The method is validated on a three-loop flux qubit quantum annealing chip, where it achieves calibration accuracy comparable to model-based methods.

Experimental results

Research questions

  • RQ1Can flux crosstalk in superconducting circuits be calibrated without assuming a specific circuit model?
  • RQ2Does exploiting the periodic response of superconducting circuits to flux provide a robust and scalable alternative to traditional calibration methods?
  • RQ3Is the periodicity-based objective function sufficiently well-behaved to allow efficient optimization, even in the presence of strong crosstalk?
  • RQ4Can this method achieve calibration accuracy comparable to model-based approaches while reducing data requirements?
  • RQ5What is the geometric structure of the periodicity landscape, and does it support efficient convergence?

Key findings

  • The proposed method achieves crosstalk calibration accuracy comparable to previous model-based methods on a three-loop flux qubit chip.
  • The periodicity-based objective function exhibits a nearly convex landscape, enabling efficient optimization with stochastic algorithms like SPSA.
  • The method requires significantly fewer measurements than high-resolution scan-based approaches, making it scalable to larger systems.
  • The approach is inherently robust to model inaccuracies and does not require detailed knowledge of the circuit Hamiltonian or coupling matrix.
  • Experimental results show that the residual crosstalk after optimization is reduced to near-identity levels, with residual matrix deviations on the order of 0.01–0.05 in normalized units.
  • The method enables closed-loop calibration, automating the process and reducing human intervention in experimental setup.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.