Skip to main content
QUICK REVIEW

[Paper Review] Performance of the Camera of the MAGIC II Telescope

D. Borla Tridon, F. Göebel|arXiv (Cornell University)|Jun 30, 2009
Adaptive optics and wavefront sensingPhysics and Astronomy9 references20 citations
TL;DR

This paper presents the performance evaluation of the upgraded camera for the MAGIC II telescope, featuring 1,039 high-quantum-efficiency photomultiplier tubes (PMTs) arranged in 169 hexagonal clusters, operating at low gain (3×10⁴) to enable moonlit observations. The system achieves a 2.5 ns pulse width and 800 photoelectron dynamic range, with future plans to replace PMTs with hybrid photon detectors (HPDs) to double photoelectron yield and improve gamma/hadron separation.

ABSTRACT

MAGIC comprises two 17m diameter IACTs to be operated in stereo mode. Currently we are commissioning the second telescope, MAGIC II. The camera of the second telescope has been equipped with 1039 pixels of 0.1-degree diameter. Always seven pixels are grouped in a hexagonal configuration to form a cluster. This modular design allows easier control and maintenance of the camera. The pixel sensors are high quantum efficiency photomultiplier tubes (PMTs) from Hamamatsu (superbialkali type, QE ~ 32% at the peak wavelength) that we operate at rather low gain of 30 k. This allows us to also perform extended observations under moderate moonlight. The system of two MAGIC telescopes will at least double the sensitivity compared to MAGIC I and also will allow us to lower the energy threshold.Here we will report the performances of the Camera of the second MAGIC telescope.

Motivation & Objective

  • To evaluate the performance of the MAGIC II telescope camera with 1,039 PMTs in 169 clusters for very high energy gamma-ray astronomy.
  • To enable extended observations under moderate moonlight by operating PMTs at low gain (3×10⁴) to prevent dynode damage.
  • To improve gamma/hadron separation and reduce night-sky background influence through a high-bandwidth (500 MHz) signal chain and 2 GSa/s digitization.
  • To prepare for future camera upgrades by integrating hybrid photon detectors (HPDs) with higher quantum efficiency and better single-photoelectron resolution.
  • To ensure thermal and mechanical stability of the camera system under outdoor conditions via a dual cooling plate design and aluminum-based lightweight construction.

Proposed method

  • The camera uses 1,039 Hamamatsu superbialkali PMTs (R10408 type) with 32% peak quantum efficiency, arranged in 169 hexagonal clusters of seven pixels each.
  • Each pixel includes a compact power unit and front-end analog processing circuitry, with a nine-step Cockroft-Walton DC-DC converter providing up to 1,250 V at low gain (3×10⁴) for safe moonlight operation.
  • Optical signals are transmitted via fiber optics to the counting house, where they are split: one branch triggers the system via a programmable-threshold discriminator, the other is digitized at 2 GSa/s using a Domino Ring Sampler (DRS) ring buffer.
  • The signal chain bandwidth is currently limited to <200 MHz due to early DRS2 chips, but will be upgraded to DRS4 chips for improved timing resolution.
  • A 3 mm UV-transmitting Plexiglas window (94% transmission at 340 nm) seals the camera, and the entire system is cooled via a liquid-cooled dual-plate design maintaining ±1°C stability.
  • Calibration includes flatfielding at 3×10⁴ gain, linearity testing over 800 photoelectrons, and single-photoelectron resolution measurements at 1,250 V with laser-induced pulses.

Experimental results

Research questions

  • RQ1How does the low-gain operation (3×10⁴) of the PMTs affect the camera’s performance during moderate moonlight observations?
  • RQ2What is the temporal resolution and pulse width of the camera’s signal chain, and how does it support gamma/hadron separation?
  • RQ3To what extent does the 32% peak quantum efficiency of the new PMTs improve sensitivity compared to MAGIC-I?
  • RQ4How does the dynamic range and single-photoelectron resolution of the camera system compare to previous IACTs?
  • RQ5What are the performance benefits and technical feasibility of replacing PMTs with hybrid photon detectors (HPDs) in the camera?

Key findings

  • The camera achieves a pulse width of approximately 2.5 ns, enabling high-time-resolution analysis of Cherenkov light flashes.
  • The dynamic range of the signal chain, from PMTs to FADC, is ≥800 photoelectrons, ensuring robust response across a wide range of signal intensities.
  • Single photoelectron resolution is confirmed at 1,250 V, with a clear Gaussian peak at the second-harmonic level in the SPE distribution, indicating reliable single-photon detection.
  • The pulse area response is proportional to the applied voltage to the power of ~4, confirming consistent gain behavior across the operating voltage range.
  • The camera’s cooling system maintains temperature stability within ±1°C across outdoor temperatures from -10°C to +30°C, ensuring stable PMT performance.
  • The upgrade path to HPDs is technically feasible, with prototype HPD clusters showing a gain of ~78,000 and well-resolved multi-photoelectron peaks, indicating a potential two-fold increase in photoelectron yield.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.