Skip to main content
QUICK REVIEW

[Paper Review] Persistence of Single Spin Coherence above 600K in Diamond

D.M. Toyli, David J. Christle|arXiv (Cornell University)|Jan 21, 2012
Diamond and Carbon-based Materials ResearchMaterials Science1 references5 citations
TL;DR

This study demonstrates that single nitrogen-vacancy (NV) centers in diamond maintain coherent spin control up to 625 K, with inhomogeneous spin lifetime (T₂*) remaining temperature-independent, enabling potential use as nanoscale thermometers. Fluorescence-based spin readout fails above 550 K due to nonradiative processes, and electronic structure calculations indicate an E–A1 state energy difference of ~0.8 eV.

ABSTRACT

We study the spin and orbital dynamics of single nitrogen vacancy (NV) centers in diamond between room temperature and 700 K. We find that the ability to optically address and coherently control single spins above room temperature is limited by nonradiative processes that quench the NV center’s fluorescence-based spin readout between 550 K and 700 K. Combined with electronic structure calculations, our measurements indicate that the energy difference between the E and A1 electronic states is ∼0.8 eV. We also find that the inhomogeneous spin lifetime (T ∗ 2 ) is independent of temperature up to at least 625 K, suggesting that single NV centers could be applied as nanoscale thermometers over a broad temperature range.

Motivation & Objective

  • To investigate the persistence of single-spin coherence in nitrogen-vacancy (NV) centers in diamond at elevated temperatures.
  • To identify the physical mechanisms limiting optical spin readout above room temperature.
  • To determine the temperature dependence of spin coherence times (T₂*) in single NV centers.
  • To correlate experimental observations with electronic structure calculations to understand the role of electronic states in spin decoherence.

Proposed method

  • Optical excitation and readout of single NV centers in diamond across temperatures from room temperature to 700 K.
  • Measurement of inhomogeneous spin coherence time (T₂*) using pulsed microwave and laser techniques.
  • Use of electronic structure calculations to estimate the energy difference between the E and A1 electronic states of the NV center.
  • Analysis of fluorescence intensity and decay dynamics to identify nonradiative processes quenching spin readout.
  • Comparison of temperature-dependent T₂* values to assess stability of spin coherence.

Experimental results

Research questions

  • RQ1What is the maximum temperature at which single-spin coherence can be maintained in NV centers in diamond?
  • RQ2What causes the loss of fluorescence-based spin readout above 550 K in NV centers?
  • RQ3How does the inhomogeneous spin coherence time (T₂*) vary with temperature up to 625 K?
  • RQ4What is the energy difference between the E and A1 electronic states of the NV center, and how does it influence spin dynamics?

Key findings

  • The inhomogeneous spin coherence time (T₂*) of single NV centers remains independent of temperature up to at least 625 K.
  • Fluorescence-based spin readout fails between 550 K and 700 K due to nonradiative processes quenching the NV center's fluorescence.
  • The energy difference between the E and A1 electronic states of the NV center is estimated to be approximately 0.8 eV.
  • The temperature-independent T₂* suggests that single NV centers could function as robust nanoscale thermometers over a broad temperature range.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.