Skip to main content
QUICK REVIEW

[Paper Review] Phase-modulated cavity magnon polaritons as a precise magnetic field probe

N. Crescini, G. Carugno|arXiv (Cornell University)|Sep 30, 2020
Atomic and Subatomic Physics ResearchPhysics and Astronomy54 references8 citations
TL;DR

This paper presents a room-temperature rf magnetic field sensor based on phase-modulated cavity magnon polaritons (CMPs) in a YIG-sphere-coupled copper cavity. By detecting sidebands induced on a pump tone due to an external rf field, the device achieves 2.0 pT/√Hz sensitivity at 220 MHz, with theoretical projections reaching 8 fT/√Hz at room temperature and sub-fT sensitivity at lower temperatures.

ABSTRACT

We describe and operate a novel spin-magnetometer based on the phase modulation of cavity magnon polaritons. In this scheme a rf magnetic field is detected through the sidebands it induces on a pump, and the experimental configuration allows for a negligible pump noise and a high frequency readout. The demonstrator setup, based on a copper cavity coupled to an yttrium iron garnet sphere hybrid system, reached a sensitivity of $2.0\,\mathrm{pT/\sqrt{Hz}}$, evading the pump noise and matching the theoretical previsions. An optimized setup can attain a rf magnetic field sensitivity of about $8\,\mathrm{fT/\sqrt{Hz}}$ at room temperature. An orders of magnitude improvement is expected at lower temperatures, making this instrument one of the few magnetometers accessing the sub-fT limit. Due to its natural applications, miniaturization and multiplexing are eventually discussed.

Motivation & Objective

  • To develop a high-sensitivity, room-temperature magnetic field sensor for ultra-low field detection.
  • To overcome limitations of cryogenic SQUIDs and shielded SERF magnetometers by enabling size-independent, high-bandwidth operation.
  • To exploit phase modulation of a microwave pump via coupling to a YIG-sphere-based cavity magnon polariton system for noise-immune field detection.
  • To achieve sensitivity competitive with state-of-the-art magnetometers while operating at ambient temperature.

Proposed method

  • A microwave cavity is coupled to a yttrium iron garnet (YIG) sphere to form a photon-magnon hybrid system (PMHS), enabling strong coupling between cavity modes and magnon resonances.
  • A monochromatic microwave pump tone is applied at the upper hybrid mode frequency (ω₂), which becomes phase-modulated by an external rf magnetic field b₁ parallel to the static bias field B₀.
  • The phase modulation generates sidebands at ω₂ ± ω_b, with the strongest component satisfying ω₂ ± ω_b = ω₁, the lower hybrid mode frequency.
  • Detection of the sideband power at ω₁ enables measurement of the perturbing rf field b₁, with minimal pump noise due to filtering and frequency-selective detection.
  • The system operates in the strong coupling regime (g₂₁ > γ₁,₂), ensuring well-defined anticrossing dispersion and high sensitivity.
  • The transduction coefficient αγ is derived from ∂ω₁,₂/∂B₀, which reduces the effective gyromagnetic ratio and enhances field sensitivity in the hybridized regime.

Experimental results

Research questions

  • RQ1Can cavity magnon polaritons be used to detect ultra-low rf magnetic fields with high sensitivity at room temperature?
  • RQ2How does phase modulation of a pump tone in a PMHS enable noise-immune detection of weak rf fields?
  • RQ3What is the theoretical and experimental sensitivity limit of such a system, and how does it compare to existing magnetometers?
  • RQ4To what extent can sensitivity be improved by optimizing the cavity-magnon coupling and operating at lower temperatures?

Key findings

  • The demonstrator setup achieved a magnetic field sensitivity of 2.0 pT/√Hz at 220 MHz, matching theoretical predictions and evading pump noise.
  • The system operates at room temperature with size-independent sensitivity, enabling applications in medical imaging, communication, and fundamental physics.
  • An optimized setup is projected to reach a sensitivity of approximately 8 fT/√Hz at room temperature, rivaling state-of-the-art magnetometers.
  • At lower temperatures, an order-of-magnitude improvement in sensitivity is expected, potentially enabling sub-femtotesla (sub-fT) field detection.
  • The phase modulation mechanism via parallel rf field coupling to the Larmor resonance enables high-frequency readout from a few MHz to several GHz.
  • The use of a waveguide filter to isolate the pump from the sideband detection line significantly reduces background noise and enhances signal-to-noise ratio.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.