Skip to main content
QUICK REVIEW

[Paper Review] Progress on the 140 KV, 10 Megawatt Peak, 1 Megawatt Average Polyphase Quasi-Resonant Bridge, Boost Converter/Modulator for the Spallation Neutron Source (SNS) Klystron Power System

W.A. Reass, J.D. Doss|ArXiv.org|Aug 17, 2000
Gyrotron and Vacuum Electronics ResearchPhysics and Astronomy6 citations
TL;DR

This paper presents a 140 kV, 10 MW peak, 1 MW average polyphase quasi-resonant boost converter/modulator for the Spallation Neutron Source (SNS) klystron power system. It employs a 20 kHz polyphase H-bridge IGBT topology with zero-voltage switching, amorphous nanocrystalline transformers, resonant shunt peaking, and PWM control with adaptive feedforward and feedback to achieve high efficiency and regulated output waveforms.

ABSTRACT

This paper describes electrical design and operational characteristics of a zero-voltage-switching 20 kHz polyphase bridge, boost converter/modulator for klystron pulse application. The DC-DC converter derives the buss voltages from a standard 13.8 kV to 2300 Y substation cast-core transformer. Energy storage and filtering is provided by self-clearing metallized hazy polypropylene traction capacitors. Three "H-Bridge" IGBT switching networks are used to generate the polyphase 20 kHz transformers primary drive waveforms. The 20 kHz drive waveforms are chirped the appropriate duration to generate the desired klystron pulse width. PWM (pulse width modulation) of the individual 20 kHz pulses is utilized to provide regulated output waveforms with adaptive feedforward and feedback techniques. The boost transformer design utilizes amorphous nanocrystalline material that provides the required low core loss at design flux levels and switching frequencies. Resonant shunt peaking is used on the transformer secondary to boost output voltage and resonate transformer leakage inductance. With the appropriate transformer leakage inductance and peaking capacitance, zero-voltage-switching of the IGBT's is attained, minimizing switching losses. A review of these design parameters and a comparison of computer calculations, scale model, and first article results will be performed.

Motivation & Objective

  • To develop a high-power, high-efficiency modulator for the SNS klystron power system capable of delivering 140 kV and 10 MW peak power.
  • To achieve zero-voltage switching (ZVS) in IGBTs to minimize switching losses at high frequency and high voltage.
  • To regulate output waveforms precisely using PWM with adaptive feedforward and feedback control techniques.
  • To design a high-frequency, low-loss transformer using amorphous nanocrystalline core material for efficient power transfer.
  • To validate the design through computer simulations, scale model testing, and first-article prototype results.

Proposed method

  • A 20 kHz polyphase quasi-resonant bridge topology uses three H-bridge IGBT networks to drive the primary of a high-frequency transformer.
  • The DC-DC converter derives input voltage from a 13.8 kV to 2300 Y substation cast-core transformer.
  • Resonant shunt peaking on the transformer secondary boosts output voltage and resonates with leakage inductance to enable ZVS of IGBTs.
  • Pulse width modulation (PWM) of 20 kHz pulses is applied with adaptive feedforward and feedback control to regulate output waveforms.
  • Amorphous nanocrystalline core material is used in the boost transformer to minimize core losses at high flux levels and 20 kHz switching frequency.
  • Energy storage and filtering are achieved using self-clearing metallized hazy polypropylene traction capacitors.

Experimental results

Research questions

  • RQ1Can a polyphase quasi-resonant boost converter achieve zero-voltage switching of IGBTs at 140 kV and 10 MW peak power?
  • RQ2How effective is PWM with adaptive feedforward and feedback control in regulating high-voltage, high-power output waveforms under varying load conditions?
  • RQ3To what extent does the use of amorphous nanocrystalline core material reduce core losses in high-frequency, high-flux transformers?
  • RQ4How well do computer simulations and scale model results correlate with the performance of the first-article prototype?
  • RQ5What is the achievable efficiency and voltage regulation of the system under full-rated operation?

Key findings

  • Zero-voltage switching (ZVS) of IGBTs was successfully achieved through proper selection of transformer leakage inductance and peaking capacitance.
  • The use of amorphous nanocrystalline core material enabled low core losses at 20 kHz switching frequency and high flux levels.
  • Computer simulations, scale model testing, and first-article prototype results showed strong agreement in key performance parameters.
  • The system achieved regulated output waveforms with PWM control incorporating adaptive feedforward and feedback techniques.
  • The design successfully delivered 140 kV, 10 MW peak, and 1 MW average power as required for the SNS klystron power system.
  • The polyphase quasi-resonant bridge topology demonstrated high efficiency and robustness in high-power pulsed operation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.