Skip to main content
QUICK REVIEW

[Paper Review] Resilient Transmission Grid Design: AC Relaxation vs. DC approximation

Harsha Nagarajan, Russell Bent|arXiv (Cornell University)|Mar 17, 2017
Optimal Power Flow DistributionEngineering18 references7 citations
TL;DR

This paper evaluates the trade-offs between AC power flow relaxation and DC approximation in resilient transmission grid design, using a mixed-integer second-order cone program to minimize load shedding under N-1 security constraints. It finds that AC relaxation yields significantly lower upgrade costs and better feasibility than DC approximation, especially under high load and voltage angle limits.

ABSTRACT

As illustrated in recent years (Superstorm Sandy, the Northeast Ice Storm of 1998, etc.), extreme weather events pose an enormous threat to the electric power transmission systems and the associated socio-economic systems that depend on reliable delivery of electric power. Besides inevitable malfunction of power grid components, deliberate malicious attacks can cause high risks to the service. These threats motivate the need for approaches and methods that improve the resilience of power systems. In this paper, we develop a model and tractable methods for optimizing the upgrade of transmission systems through a combination of hardening existing components, adding redundant lines, switches, generators, and FACTS and phase-shifting devices. While many of these controllable components are included in traditional design (expansion planning) problems, we uniquely assess their benefits from a resiliency point of view. More importantly, perhaps, we evaluate the suitability of using state-of-the-art AC power flow relaxations versus the common DC approximation in resilience improvement studies. The resiliency model and algorithms are tested on a modified version of the RTS-96 (single area) system.

Motivation & Objective

  • To assess the impact of AC power flow relaxation versus DC approximation on transmission grid resilience and upgrade costs.
  • To quantify the minimum load shedding required to ensure AC power flow feasibility under various loading and voltage angle constraints.
  • To evaluate the cost-effectiveness of Flexible AC Transmission System (FACTS) devices in reducing network upgrade costs.
  • To compare the performance of DC approximation and AC relaxation across varying load scales and voltage angle limits.
  • To determine the conditions under which AC relaxation provides superior resilience and cost efficiency compared to DC approximation.

Proposed method

  • Formulates a mixed-integer second-order cone program to minimize total load shedding (active and reactive) while satisfying AC power flow constraints.
  • Uses a bi-level optimization framework: first, determine optimal network topology and device placement (x*, τ*, t*, u*, zp*, zq*), then assess AC feasibility under fixed parameters.
  • Applies DC approximation by fixing zp* and setting bounds on zq* as ±zp*/2, simplifying the AC constraints into linearized equivalents.
  • Introduces a load shedding minimization problem with four slack variables (λp_cr, λq_cr, λp_ncr, λq_ncr) to represent critical and non-critical active and reactive power shedding.
  • Computes percent apparent-load shed using Euclidean norms of shed active and reactive power relative to total demand.
  • Evaluates FACTS device impact by comparing upgrade costs with and without VAR compensators, computing savings as a percentage of base cost.

Experimental results

Research questions

  • RQ1How do AC relaxation and DC approximation compare in terms of required network upgrade costs under varying load and voltage angle constraints?
  • RQ2What is the minimum amount of active and reactive power that must be shed to ensure AC power flow feasibility under N-1 contingency conditions?
  • RQ3How does the inclusion of FACTS devices affect the cost and feasibility of resilient transmission grid design?
  • RQ4At what load scale and voltage angle limit does the DC approximation begin to significantly underestimate system resilience compared to AC relaxation?
  • RQ5What is the maximum achievable cost savings from using FACTS devices in transmission network upgrades under different loading scenarios?

Key findings

  • At a load factor of 1.30 and θᵘ = 45°, the DC approximation requires significantly higher upgrade costs than AC relaxation, with savings of up to 30% when FACTS devices are used.
  • For p = 0.5 and θᵘ = 45°, the AC relaxation approach results in approximately 1.5·10⁷ USD in upgrade costs, while the DC approximation exceeds 2.0·10⁷ USD under the same conditions.
  • The use of FACTS devices reduces total upgrade costs by up to 25% compared to designs without them, particularly under high load and high voltage angle conditions.
  • At θᵘ = 15° and p = 0.1, the DC approximation underestimates the required network reinforcement, leading to infeasible AC power flows even when the DC solution appears feasible.
  • The apparent-load shed ratio increases with load scale and voltage angle limits, with AC relaxation consistently requiring less load shedding than DC approximation across all tested scenarios.
  • The highest cost savings from FACTS devices occur at high load scales (e.g., 1.25× base load), where savings exceed 20% when reactance reduction factor is 0.5.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.