Skip to main content
QUICK REVIEW

[Paper Review] Sensor Fusion using Backward Shortcut Connections for Sleep Apnea Detection in Multi-Modal Data

Tom Van Steenkiste, Dirk Deschrijver|arXiv (Cornell University)|Dec 14, 2019
Obstructive Sleep Apnea ResearchMedicine26 references12 citations
TL;DR

This paper proposes a novel late sensor fusion method using backward shortcut connections (BFM-SC) to improve deep learning-based sleep apnea detection across multi-modal respiratory, ECG, and oximetry signals. By enabling residual gradient flow from late fusion layers back to individual sensor branches, BFM-SC significantly boosts model performance and robustness over single-sensor, early fusion, and standard late fusion approaches, achieving state-of-the-art AUC and F1 scores on the SHHS-1 dataset with both CNN and LSTM architectures.

ABSTRACT

Sleep apnea is a common respiratory disorder characterized by breathing pauses during the night. Consequences of untreated sleep apnea can be severe. Still, many people remain undiagnosed due to shortages of hospital beds and trained sleep technicians. To assist in the diagnosis process, automated detection methods are being developed. Recent works have demonstrated that deep learning models can extract useful information from raw respiratory data and that such models can be used as a robust sleep apnea detector. However, trained sleep technicians take into account multiple sensor signals when annotating sleep recordings instead of relying on a single respiratory estimate. To improve the predictive performance and reliability of the models, early and late sensor fusion methods are explored in this work. In addition, a novel late sensor fusion method is proposed which uses backward shortcut connections to improve the learning of the first stages of the models. The performance of these fusion methods is analyzed using CNN as well as LSTM deep learning base-models. The results demonstrate a significant and consistent improvement in predictive performance over the single sensor methods and over the other explored sensor fusion methods, by using the proposed sensor fusion method with backward shortcut connections.

Motivation & Objective

  • To address the clinical challenge of undiagnosed sleep apnea due to limited sleep technician availability and long diagnostic waiting times.
  • To improve automated sleep apnea detection by fusing multiple physiological signals—abdominal and thoracic respiratory belts, heart rate, and SpO2—beyond single-sensor models.
  • To develop a novel sensor fusion framework that enhances learning in late fusion architectures using backward shortcut connections.
  • To validate the proposed method on both CNN and LSTM deep learning models for robust performance across different architectures.
  • To improve model interpretability by enabling per-sensor performance monitoring through the residual connections.

Proposed method

  • Proposes a late fusion architecture where each sensor signal is processed by a separate branch network before feature fusion at the final layer.
  • Introduces backward shortcut connections (BFM-SC) that allow gradients from the final fusion layer to flow back to the initial layers of each sensor branch, improving training stability and feature learning.
  • Uses residual-style skip connections that are active during training but can be removed at inference, preserving model interpretability.
  • Employs Global Average Pooling (GAP) and dropout layers in the CNN-based model, and bidirectional LSTM layers in the LSTM-based model for temporal feature extraction.
  • Applies early fusion (MIM) and single-input models (SIM) as baselines for comparison, using identical model architectures except for input fusion strategy.
  • Utilizes a paired t-test and heteroscedastic t-test to statistically validate performance and robustness improvements across five non-overlapping datasets.

Experimental results

Research questions

  • RQ1Can backward shortcut connections in a late fusion framework significantly improve the predictive performance of deep learning models for sleep apnea detection across multi-modal physiological signals?
  • RQ2How does the proposed BFM-SC method compare in performance and robustness to single-sensor models, early fusion, and standard late fusion approaches?
  • RQ3To what extent can the backward shortcut connections enhance model interpretability by enabling per-sensor performance monitoring?
  • RQ4Does the BFM-SC method maintain consistent improvements across different deep learning architectures, such as CNN and LSTM?
  • RQ5How generalizable is the BFM-SC approach when applied to diverse sleep apnea datasets and multi-sensor configurations?

Key findings

  • The BFM-SC method achieved a statistically significant improvement in performance (p < 0.05) over all baseline methods, including single-input models (SIM), early fusion (MIM), and standard late fusion (BFM), across both CNN and LSTM models.
  • For the CNN-based model, BFM-SC achieved an AUC of 0.938 and F1-score of 0.812, outperforming the best SIM (abdores) with AUC 0.914 and F1 0.778.
  • For the LSTM-based model, BFM-SC achieved an AUC of 0.941 and F1-score of 0.821, surpassing the best SIM (thorres) with AUC 0.923 and F1 0.795.
  • Statistical significance testing confirmed that BFM-SC consistently outperformed all baselines in both performance (p < 0.05) and robustness (p < 0.05) across all five datasets.
  • The individual branches in the BFM-SC architecture achieved performance close to that of separately trained SIM models, indicating effective and stable learning per sensor modality.
  • The backward shortcut connections enabled interpretable outputs by allowing per-sensor prediction heads, offering insights into which signals contributed most to the final decision.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.