[Paper Review] Skin Deep Unlearning: Artefact and Instrument Debiasing in the Context of Melanoma Classification
This paper proposes using unlearning techniques—specifically 'Learning Not to Learn' (LNTL) and 'Turning a Blind Eye'—to debias convolutional neural networks (CNNs) in melanoma classification, mitigating biases from surgical markings and rulers, and reducing spurious variation from imaging instruments. The approach improves model robustness and generalization, with AUC gains up to 15.3% on biased data and performance exceeding dermatologists on benchmark datasets.
Convolutional Neural Networks have demonstrated dermatologist-level performance in the classification of melanoma from skin lesion images, but prediction irregularities due to biases seen within the training data are an issue that should be addressed before widespread deployment is possible. In this work, we robustly remove bias and spurious variation from an automated melanoma classification pipeline using two leading bias unlearning techniques. We show that the biases introduced by surgical markings and rulers presented in previous studies can be reasonably mitigated using these bias removal methods. We also demonstrate the generalisation benefits of unlearning spurious variation relating to the imaging instrument used to capture lesion images. Our experimental results provide evidence that the effects of each of the aforementioned biases are notably reduced, with different debiasing techniques excelling at different tasks.
Motivation & Objective
- Address bias in melanoma classification caused by surgical markings and rulers in skin lesion images, which can degrade model performance.
- Mitigate spurious variation due to differences in imaging instruments to improve model generalization across diverse clinical settings.
- Develop a debiasing framework that does not require altering clinical practices or pre-processing images, enabling real-world deployment.
- Demonstrate that unlearning techniques can enhance model performance on both biased and unbiased data without sacrificing accuracy.
- Evaluate the effectiveness of debiasing methods across multiple benchmark datasets with varying domain shifts.
Proposed method
- Apply 'Learning Not to Learn' (LNTL) and 'Turning a Blind Eye' unlearning methods to suppress model reliance on artefacts such as surgical markings and rulers.
- Use gradient reversal layers in LNTL to encourage the feature extractor to learn representations invariant to artefact presence.
- Treat image size as a proxy for imaging instrument type to model and remove instrument-specific biases.
- Train a shared feature extractor with auxiliary debiasing heads that predict artefact presence and guide the main classifier to ignore spurious cues.
- Fine-tune models on multiple test sets (e.g., ISIC, MClass, Asan) to evaluate generalization under domain shift.
- Perform ablation studies to validate the necessity of gradient reversal and debiasing heads in the training pipeline.
Experimental results
Research questions
- RQ1Can unlearning techniques effectively reduce model bias caused by surgical markings and rulers in skin lesion images?
- RQ2How do different debiasing methods (LNTL vs. Turning a Blind Eye) compare in performance when mitigating artefact-related biases?
- RQ3To what extent can unlearning improve model generalization across datasets with varying imaging instruments?
- RQ4Does removing artefact and instrument biases compromise performance on clean, artefact-free images?
- RQ5Can debiasing methods lead to performance exceeding that of experienced dermatologists on standardized benchmarks?
Key findings
- The LNTL method improved AUC by 6.1% when removing bias from surgical markings, demonstrating effective debiasing without performance loss on clean images.
- Utilizing confusion loss with gradient reversal in LNTL increased AUC by 15.3% on images with rulers, significantly outperforming the baseline.
- The 'Turning a Blind Eye' method achieved an 11.6% AUC increase over the baseline on the Asan dataset when removing instrument-related biases.
- Debiased models maintained or improved performance on test sets without artefacts, confirming that unlearning does not degrade generalization.
- The proposed models outperformed the average dermatologist on the MClass benchmark, achieving higher AUC scores across multiple test sets.
- Ablation studies confirmed that removing the gradient reversal layer in LNTL degraded performance, validating its critical role in bias mitigation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.