Skip to main content
QUICK REVIEW

[Paper Review] Spatiotemporal implicit neural representation for unsupervised dynamic MRI reconstruction

Jie Feng, Ruimin Feng|arXiv (Cornell University)|Dec 31, 2022
Advanced MRI Techniques and ApplicationsMedicine8 citations
TL;DR

This paper proposes an unsupervised spatiotemporal implicit neural representation (INR) for dynamic MRI reconstruction from highly undersampled k-space data, using only spatiotemporal coordinates as input and optimizing the INR via data consistency and explicit low-rank/sparsity regularization. The method achieves state-of-the-art performance, improving PSNR by 5.5–7.1 dB at 41.6× acceleration on cardiac cine data, with strong internal continuity enabling high-quality temporal super-resolution without additional training.

ABSTRACT

Supervised Deep-Learning (DL)-based reconstruction algorithms have shown state-of-the-art results for highly-undersampled dynamic Magnetic Resonance Imaging (MRI) reconstruction. However, the requirement of excessive high-quality ground-truth data hinders their applications due to the generalization problem. Recently, Implicit Neural Representation (INR) has appeared as a powerful DL-based tool for solving the inverse problem by characterizing the attributes of a signal as a continuous function of corresponding coordinates in an unsupervised manner. In this work, we proposed an INR-based method to improve dynamic MRI reconstruction from highly undersampled k-space data, which only takes spatiotemporal coordinates as inputs. Specifically, the proposed INR represents the dynamic MRI images as an implicit function and encodes them into neural networks. The weights of the network are learned from sparsely-acquired (k, t)-space data itself only, without external training datasets or prior images. Benefiting from the strong implicit continuity regularization of INR together with explicit regularization for low-rankness and sparsity, our proposed method outperforms the compared scan-specific methods at various acceleration factors. E.g., experiments on retrospective cardiac cine datasets show an improvement of 5.5 ~ 7.1 dB in PSNR for extremely high accelerations (up to 41.6-fold). The high-quality and inner continuity of the images provided by INR has great potential to further improve the spatiotemporal resolution of dynamic MRI, without the need of any training data.

Motivation & Objective

  • Address the generalization limitations of supervised deep learning in dynamic MRI due to reliance on large, high-quality ground-truth datasets.
  • Overcome the data scarcity and acquisition constraints in dynamic MRI, especially for DCE-MRI where ground truth is unavailable.
  • Develop a training-free, unsupervised reconstruction method that leverages implicit neural representation for high-quality image recovery from highly undersampled k-space data.
  • Preserve motion fidelity and temporal continuity in dynamic MRI sequences without external priors or prior images.
  • Enable temporal super-resolution by exploiting the intrinsic continuity of the learned INR function, allowing interpolation at higher temporal sampling rates.

Proposed method

  • Represent dynamic MRI as a continuous implicit function mapping spatiotemporal coordinates (k, t) to image intensities using a multi-layer perceptron (MLP).
  • Train the INR using only the acquired undersampled k-space data, enforcing data consistency via a differentiable loss function.
  • Incorporate explicit regularization for low-rank structure (nuclear norm) and sparsity (L1 norm) to promote temporal and spatial coherence.
  • Optimize the INR parameters using gradient descent, with no need for external training data or pre-trained models.
  • Utilize hierarchical feature representation via hash grids to improve training efficiency and representation quality.
  • Enable temporal super-resolution by querying the optimized INR at denser temporal coordinates, producing interpolated frames without additional training.

Experimental results

Research questions

  • RQ1Can an implicit neural representation reconstruct highly undersampled dynamic MRI sequences without any external training data or ground-truth images?
  • RQ2How well does the intrinsic continuity of INR preserve motion fidelity and temporal dynamics in dynamic MRI at extreme acceleration factors?
  • RQ3To what extent can the learned INR support temporal super-resolution beyond the original acquisition rate?
  • RQ4How does the proposed method compare to state-of-the-art CS-based and unsupervised DL methods in terms of reconstruction quality and robustness?
  • RQ5What is the impact of explicit low-rank and sparsity regularization on the performance of INR-based dynamic MRI reconstruction?

Key findings

  • The proposed method achieves a PSNR improvement of 5.5–7.1 dB over baseline methods at 41.6× acceleration on retrospective cardiac cine datasets.
  • The method outperforms traditional CS-based methods such as L+S and GRASP in artifact suppression and structural preservation, especially at ultra-high acceleration factors.
  • The INR-based reconstruction exhibits strong internal continuity, enabling high-quality temporal super-resolution with 4× upsampling, as validated by visual and quantitative comparison with linear interpolation.
  • The reconstructed images maintain high temporal fidelity, with smooth motion transitions observed between frames, particularly evident in the heart chamber dynamics.
  • The method is completely unsupervised and does not require any training data or prior images, demonstrating robust generalization across different acceleration rates.
  • The temporal super-resolution capability is achieved without additional training or modeling, simply by querying the optimized INR at denser temporal coordinates, reducing deployment complexity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.