TL;DR

This paper proposes a hierarchical spectral clustering framework for intentional islanding in resilient hybrid energy systems with high renewable penetration. By integrating frequency measurements and multi-source electrical data via Grassmann manifold embedding, the method enables dynamic, robust clustering that stabilizes voltage angles and mitigates cascading failures, demonstrated on IEEE 9- and 118-bus systems with wind farms.

ABSTRACT

Establishing cleaner energy generation therefore improving the sustainability of the power system is a crucial task in this century, and one of the key strategies being pursued is to shift the dependence on fossil fuel to renewable technologies such as wind, solar, and nuclear. However, with the increasing number of heterogeneous components included, the complexity of the hybrid energy system becomes more significant. And the complex system imposes a more stringent requirement of the contingency plan to enhance the overall system resilience. Among different strategies to ensure a reliable system, intentional islanding is commonly applied in practical applications for power systems and attracts abundant interest in the literature. In this study, we propose a hierarchical spectral clustering-based intentional islanding strategy at the transmission level with renewable generations. To incorporate the renewable generation that relies on the inverter technology, the frequency measurements are considered to represent the transient response. And it has been further used as embedded information in the clustering algorithm along with other important electrical information from the system to enrich the modeling capability of the proposed framework. To demonstrate the effectiveness of the islanding strategy, the modified IEEE-9 bus and IEEE-118 bus systems coupled with wind farms are considered as the test cases.

Motivation & Objective

  • Address the growing challenge of system resilience in hybrid energy systems (HES) with increasing renewable integration and system complexity.
  • Develop a proactive contingency plan to prevent cascading failures after disruptive events, especially in systems dominated by inverter-based renewable sources.
  • Create a universal, adaptive intentional islanding strategy that unifies heterogeneous real-time measurements for robust decision-making during transient disturbances.
  • Enhance system self-healing capability by enabling stable, synchronized operation of isolated subsystems post-disruption, particularly through voltage angle stabilization.

Proposed method

  • Apply hierarchical spectral clustering to partition transmission networks into isolated, self-sustaining subsystems after disturbances.
  • Incorporate multi-layered system measurements—topology, electrical distance, and frequency deviation—as input features for clustering.
  • Use Grassmann manifold learning to embed heterogeneous data into a unified low-dimensional space, preserving geometric relationships critical for clustering.
  • Leverage the hierarchical structure of spectral clustering to allow flexible selection of the number of islands based on operational constraints or stakeholder preferences.
  • Formulate the clustering objective using a similarity matrix derived from embedded features, enabling robust partitioning even under dynamic conditions.
  • Validate the framework using transient simulations on modified IEEE 9-bus and 118-bus systems with integrated wind farms.

Experimental results

Research questions

  • RQ1How can a clustering-based intentional islanding strategy be designed to effectively manage transient dynamics in hybrid energy systems with high renewable penetration?
  • RQ2To what extent can frequency deviation measurements improve the accuracy and resilience of islanding decisions in systems dominated by inverter-based generation?
  • RQ3Can a unified embedding framework combining topology, electrical distance, and frequency data enhance the robustness of spectral clustering for islanding?
  • RQ4How does the proposed method stabilize voltage angles and prevent cascading failures compared to non-islanding operation in large-scale systems?

Key findings

  • The proposed framework successfully partitions the modified IEEE 118-bus system into four stable, isolated subsystems after a line outage, as confirmed by the dendrogram and clustering results.
  • Voltage magnitude oscillations were damped under the intentional islanding strategy, indicating improved transient stability, particularly for buses located far from the fault location.
  • Without intentional islanding, voltage angles at selected buses (30, 38, 75, 103) diverged significantly after the fault, indicating loss of synchronism and risk of cascading failure.
  • With intentional islanding, voltage angles across all selected buses remained synchronized and stabilized near pre-disturbance levels, demonstrating effective prevention of cascading failure.
  • The integration of frequency deviation as a key input feature significantly enhanced the model’s ability to capture dynamic system behavior, especially in systems with inverter-based renewables.
  • The Grassmann manifold-based embedding enabled effective fusion of heterogeneous data sources, improving clustering robustness and adaptability to varying system conditions.