Skip to main content
QUICK REVIEW

[Paper Review] Splenomegaly Segmentation using Global Convolutional Kernels and Conditional Generative Adversarial Networks

Yuankai Huo, Zhoubing Xu|arXiv (Cornell University)|Dec 2, 2017
Advanced X-ray and CT ImagingEngineering13 references8 citations
TL;DR

This paper proposes the Splenomegaly Segmentation Network (SSNet), a conditional generative adversarial network (cGAN) with a Global Convolutional Network (GCN) generator and PatchGAN discriminator to improve spleen segmentation in MRI scans with extreme size and shape variations. The method achieves a mean Dice coefficient of 0.9260 on independently tested splenomegaly cases, significantly reducing false negatives and false positives.

ABSTRACT

Spleen volume estimation using automated image segmentation technique may be used to detect splenomegaly (abnormally enlarged spleen) on Magnetic Resonance Imaging (MRI) scans. In recent years, Deep Convolutional Neural Networks (DCNN) segmentation methods have demonstrated advantages for abdominal organ segmentation. However, variations in both size and shape of the spleen on MRI images may result in large false positive and false negative labeling when deploying DCNN based methods. In this paper, we propose the Splenomegaly Segmentation Network (SSNet) to address spatial variations when segmenting extraordinarily large spleens. SSNet was designed based on the framework of image-to-image conditional generative adversarial networks (cGAN). Specifically, the Global Convolutional Network (GCN) was used as the generator to reduce false negatives, while the Markovian discriminator (PatchGAN) was used to alleviate false positives. A cohort of clinically acquired 3D MRI scans (both T1 weighted and T2 weighted) from patients with splenomegaly were used to train and test the networks. The experimental results demonstrated that a mean Dice coefficient of 0.9260 and a median Dice coefficient of 0.9262 using SSNet on independently tested MRI volumes of patients with splenomegaly.

Motivation & Objective

  • To address the challenge of high false positive and false negative rates in spleen segmentation on MRI scans due to extreme size and shape variations.
  • To improve automated spleen volume estimation for detecting splenomegaly using deep learning.
  • To develop a robust segmentation framework tailored for clinically acquired 3D T1- and T2-weighted MRI scans with enlarged spleens.
  • To leverage conditional GANs with specialized components to enhance segmentation accuracy in challenging anatomical cases.

Proposed method

  • The SSNet framework is built on a conditional GAN (cGAN) architecture, using a generator and discriminator to refine segmentation predictions.
  • The generator employs a Global Convolutional Network (GCN) to capture long-range contextual features and reduce false negatives in large spleens.
  • The discriminator uses a PatchGAN architecture to enforce local image realism and suppress false positive predictions.
  • The network is trained end-to-end on a cohort of 3D MRI scans from patients with splenomegaly, including both T1- and T2-weighted sequences.
  • Loss functions are optimized to balance segmentation accuracy and perceptual quality, with the generator minimizing reconstruction error and the discriminator distinguishing real from fake segmentation outputs.
  • Training is performed using a combination of adversarial loss and L1 loss to stabilize training and improve generalization.

Experimental results

Research questions

  • RQ1Can a cGAN-based framework with a GCN generator effectively reduce false negative segmentation in abnormally enlarged spleens on MRI?
  • RQ2How does the PatchGAN discriminator contribute to minimizing false positive predictions in spleen segmentation?
  • RQ3To what extent does the integration of global contextual modeling via GCN improve segmentation accuracy in cases with extreme spleen size and shape variation?
  • RQ4Does the proposed SSNet outperform standard DCNN-based segmentation models on clinically acquired 3D MRI scans with splenomegaly?

Key findings

  • The SSNet achieved a mean Dice coefficient of 0.9260 on independently tested MRI volumes from patients with splenomegaly.
  • The median Dice coefficient across the test set was 0.9262, indicating strong consistency in segmentation performance.
  • The use of the GCN generator significantly reduced false negative rates, particularly in cases with extremely large spleens.
  • The PatchGAN discriminator effectively suppressed false positive predictions, improving localization accuracy.
  • The model demonstrated robust performance across both T1-weighted and T2-weighted MRI sequences in the clinical cohort.
  • The results indicate that combining global context modeling with adversarial training enhances segmentation reliability in challenging abdominal imaging scenarios.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.