[Paper Review] SSC-UNet: UNet with Self-Supervised Contrastive Learning for Phonocardiography Noise Reduction
The paper proposes SSC-UNet, a self-supervised Noise2Noise-based denoising model with contrastive learning for phonocardiography, improving noise reduction without clean data and preserving pathological features.
Congenital Heart Disease (CHD) remains a significant global health concern affecting approximately 1\% of births worldwide. Phonocardiography has emerged as a supplementary tool to diagnose CHD cost-effectively. However, the performance of these diagnostic models highly depends on the quality of the phonocardiography, thus, noise reduction is particularly critical. Supervised UNet effectively improves noise reduction capabilities, but limited clean data hinders its application. The complex time-frequency characteristics of phonocardiography further complicate finding the balance between effectively removing noise and preserving pathological features. In this study, we proposed a self-supervised phonocardiography noise reduction model based on Noise2Noise to enable training without clean data. Augmentation and contrastive learning are applied to enhance its performance. We obtained an average SNR of 12.98 dB after filtering under 10~dB of hospital noise. Classification sensitivity after filtering was improved from 27\% to 88\%, indicating its promising pathological feature retention capabilities in practical noisy environments.
Motivation & Objective
- Address scarcity of clean phonocardiography data for denoising.
- Develop an end-to-end self-supervised denoising model based on Noise2Noise.
- Incorporate contrastive learning to preserve pathological features and reduce hallucinations.
- Evaluate denoising performance across diverse real-world noise scenarios and assess impact on CHD classification.
- Demonstrate robustness and potential generalization to other physiological signals.
Proposed method
- Adopt a four-level U-Net (LU-Net) with BiLSTM skip connections to retain temporal details.
- Project bottleneck features into a contrastive space via a projection head.
- Train with a combined loss: reconstruction loss (MSE) plus a contrastive loss to cluster augmentations of the same sample.
- Use Noise2Noise-inspired training by injecting additional distortion into noisy PCG inputs without requiring clean targets.
- Implement a contrastive learning framework where positive pairs are augmentations of the same sample and negatives are other samples, optimizing a stability-aware latent space.
- Evaluate using end-to-end training on augmented PCG data and compare against baseline denoising models.
Experimental results
Research questions
- RQ1Can a self-supervised denoising model trained without clean data achieve competitive SNR improvements on noisy phonocardiograms?
- RQ2Does contrastive learning help preserve pathogenic features and reduce hallucinations in UNet-based denoising for PCG?
- RQ3How does SSC-UNet perform across different noise types (white, pink, red, hospital, lung) and noise levels?
- RQ4What is the impact of denoising on downstream CHD classification robustness under noisy conditions?
Key findings
- SSC-UNet outperforms traditional UNet-based denoising under several noise conditions in terms of output SNR.
- With 0 dB hospital noise, SSC-UNet achieves an SNR of 14 dB, higher than FCN, U-Net, and LU-Net baselines.
- Contrastive learning reduces blurring and hallucination, improving preservation of pathological PCG features.
- The method enhances downstream five-class CHD classification performance under noisy conditions compared with no denoising.
- t-SNE visualization shows contrastive learning yields clearer clustering of different PCG patterns in the latent space without labels.
- The approach demonstrates robustness to various noise types and suggests potential applicability to other physiological signals.