[Paper Review] StarDICE I: sensor calibration bench and absolute photometric calibration of a Sony IMX411 sensor

M. Betoule, S. Antier|arXiv (Cornell University)|Nov 9, 2022
CCD and CMOS Imaging SensorsEngineering4 citations
TL;DR

This paper presents a fully automated spectrophotometric calibration bench that enables absolute photometric calibration of the Sony IMX411ALR CMOS sensor (in the QHY411M camera) using NIST-traceable photodiodes. It achieves sub-0.001 e⁻/photon statistical uncertainty in quantum efficiency from 387–950 nm, with 1% overall normalization uncertainty and excellent response stability (<0.0033% RMS), making it highly suitable for precision photometry in astronomical surveys and gravitational wave follow-up.

ABSTRACT

The Hubble diagram of type-Ia supernovae (SNe-Ia) provides cosmological constraints on the nature of dark energy with an accuracy limited by the flux calibration of currently available spectrophotometric standards. The StarDICE experiment aims at establishing a 5-stage metrology chain from NIST photodiodes to stars, with a targeted accuracy of \SI{1}{mmag} in $griz$ colors. We present the first two stages, resulting in the calibration transfer from NIST photodiodes to a demonstration \SI{150}{Mpixel} CMOS sensor (Sony IMX411ALR as implemented in the QHY411M camera by QHYCCD). As a side-product, we provide full characterization of this camera. A fully automated spectrophotometric bench is built to perform the calibration transfer. The sensor readout electronics is studied using thousands of flat-field images from which we derive stability, high resolution photon transfer curves and estimates of the individual pixel gain. The sensor quantum efficiency is then measured relative to a NIST-calibrated photodiode. Flat-field scans at 16 different wavelengths are used to build maps of the sensor response. We demonstrate statistical uncertainty on quantum efficiency below \SI{0.001}{e^-/γ} between \SI{387}{nm} and \SI{950}{nm}. Systematic uncertainties in the bench optics are controlled at the level of \SI{1e-3}{e^-/γ}. Uncertainty in the overall normalization of the QE curve is 1\%. Regarding the camera we demonstrate stability in steady state conditions at the level of \SI{32.5}{ppm}. Homogeneity in the response is below \SI{1}{\percent} RMS across the entire sensor area. Quantum efficiency stays above \SI{50}{\percent} in most of the visible range, peaking well above \SI{80}{\percent} between \SI{440}{nm} and \SI{570}{nm}. Differential non-linearities at the level of \SI{1}{\percent} are detected. A simple 2-parameter model is proposed to mitigate the effect.

Motivation & Objective

  • To establish a metrology chain from NIST photodiodes to astronomical stars, targeting 1 mmag accuracy in griz colors for cosmological studies.
  • To perform absolute photometric calibration of the 150 Mpixel CMOS sensor (Sony IMX411ALR) used in the QHY411M camera.
  • To characterize the sensor’s quantum efficiency, linearity, uniformity, and non-linearities for use in precision astronomical photometry.
  • To support future applications in transient detection, particularly optical follow-up of gravitational wave events.
  • To identify and quantify systematic and statistical uncertainties in the calibration process for improved accuracy.

Proposed method

  • A custom-built, fully automated spectrophotometric bench was constructed to transfer calibration from NIST-traceable photodiodes to the CMOS sensor.
  • Thousands of flat-field images were acquired to assess readout stability, derive high-resolution photon transfer curves, and estimate individual pixel gains.
  • Quantum efficiency was measured relative to a NIST-calibrated photodiode across a monochromatic beam from 375 to 1078 nm.
  • Flat-field scans at 16 wavelengths were used to generate detailed spatial response maps of the sensor.
  • A two-parameter model was applied to correct for periodic differential non-linearity in the ADC response.
  • Systematic uncertainties in bench optics were controlled to within 1×10⁻³ e⁻/photon.

Experimental results

Research questions

  • RQ1What is the statistical uncertainty in the quantum efficiency measurement of the Sony IMX411ALR sensor across the visible and near-infrared spectrum?
  • RQ2How stable is the sensor’s response under steady-state conditions, and what is the uniformity of its response across the sensor area?
  • RQ3To what extent do non-linearities, particularly differential non-linearity, affect the sensor’s linearity and dynamic range?
  • RQ4What is the overall normalization uncertainty of the quantum efficiency curve, and how does it impact photometric accuracy?
  • RQ5Can the sensor be reliably used for precision photometry in astronomical surveys, especially for transient detection and cosmological distance measurements?

Key findings

  • Statistical uncertainty in quantum efficiency is below 0.001 e⁻/photon between 387 nm and 950 nm, limited by sensor sensitivity in the infrared.
  • Systematic uncertainties in the bench optics are controlled at the 1×10⁻³ e⁻/photon level.
  • The sensor exhibits excellent stability with <0.0033% RMS variation in steady-state conditions.
  • Quantum efficiency exceeds 50% across most of the visible spectrum, peaking above 80% between 440 nm and 570 nm.
  • The camera shows uniformity in response at or below 1% RMS across the entire sensor area.
  • Periodic differential non-linearity is detected at the 1% level, but a two-parameter model effectively corrects the shape of the photon transfer curve up to ~20 ke⁻.