Skip to main content
QUICK REVIEW

[Paper Review] StenUNet: Automatic Stenosis Detection from X-ray Coronary Angiography

Hui Lin, Tom Liu|arXiv (Cornell University)|Oct 23, 2023
Coronary Interventions and DiagnosticsMedicine5 citations
TL;DR

StenUNet is a U-Net-based deep learning model that enables accurate, pixel-wise stenosis detection in X-ray coronary angiography, achieving an F1 score of 53.48% on the ARCADE challenge test set—ranking 3rd among all teams. It combines preprocessing to reduce false positives and post-processing to eliminate small spurious segments, significantly improving detection precision over baseline methods.

ABSTRACT

Coronary angiography continues to serve as the primary method for diagnosing coronary artery disease (CAD), which is the leading global cause of mortality. The severity of CAD is quantified by the location, degree of narrowing (stenosis), and number of arteries involved. In current practice, this quantification is performed manually using visual inspection and thus suffers from poor inter- and intra-rater reliability. The MICCAI grand challenge: Automatic Region-based Coronary Artery Disease diagnostics using the X-ray angiography imagEs (ARCADE) curated a dataset with stenosis annotations, with the goal of creating an automated stenosis detection algorithm. Using a combination of machine learning and other computer vision techniques, we propose the architecture and algorithm StenUNet to accurately detect stenosis from X-ray Coronary Angiography. Our submission to the ARCADE challenge placed 3rd among all teams. We achieved an F1 score of 0.5348 on the test set, 0.0005 lower than the 2nd place.

Motivation & Objective

  • To address the high inter- and intra-rater variability in manual stenosis assessment from X-ray coronary angiography.
  • To develop an automated, reproducible method for stenosis detection that improves accuracy and reduces clinical workload.
  • To achieve precise pixel-wise segmentation of stenotic regions rather than relying on bounding boxes or class activation maps.
  • To enhance robustness in low-quality or challenging frames through preprocessing and post-processing techniques.
  • To enable real-time deployment with inference time under 5 seconds per image, suitable for clinical integration.

Proposed method

  • StenUNet employs a U-Net architecture with encoder-decoder structure and skip connections to preserve spatial details for pixel-wise segmentation.
  • The model uses a combination of preprocessing (e.g., vessel enhancement and noise reduction) to suppress false positives before detection.
  • Post-processing applies morphological operations and size filtering to remove small, spurious segments that are likely false positives.
  • The network is trained end-to-end using binary cross-entropy loss on pixel-level stenosis annotations from the ARCADE dataset.
  • Temporal information from sequential frames is not used in this version, though future extensions may incorporate RNNs or transformers.
  • Inference time is constrained to under 5 seconds per image to meet clinical deployment requirements.
Figure 1: The proposed pipeline for stenosis detection from X-ray angiography. An example is from the testing set. StenUNet’s architecture is depicted in Fig. 2 .
Figure 1: The proposed pipeline for stenosis detection from X-ray angiography. An example is from the testing set. StenUNet’s architecture is depicted in Fig. 2 .

Experimental results

Research questions

  • RQ1Can a U-Net-based architecture achieve high-precision, pixel-wise stenosis segmentation in X-ray coronary angiograms?
  • RQ2How do preprocessing and post-processing steps individually and jointly affect detection performance in stenosis detection?
  • RQ3To what extent does the model generalize to low-contrast or noisy frames where stenosis is visually ambiguous?
  • RQ4How does the F1 score of StenUNet compare to state-of-the-art methods that use bounding boxes or attention maps?
  • RQ5What are the primary failure modes of the model, particularly in detecting thin or faint vessels?

Key findings

  • StenUNet achieved an F1 score of 53.48% on the ARCADE challenge test set, ranking 3rd among all participating teams.
  • The ablation study showed that preprocessing alone improved F1 by 1.26%, while post-processing alone improved it by 3.4%, and together they boosted performance by 4.66%.
  • Post-processing was particularly effective in removing numerous small false positive segments, as visually confirmed by green circles in Fig. 4.
  • The model struggled to detect thin, low-contrast arterial segments, especially where vessel intensity was significantly lower than surrounding structures.
  • False positives were frequently generated in areas of vessel crossing, where dense intersections confused the model, as indicated by yellow arrows in Fig. 5.
  • Despite not using temporal information, the model demonstrated strong performance, suggesting potential for future integration of sequential frame modeling.
Figure 2: The proposed UNet-based StenUNet for stenosis detection. The reader is referred to Section 2 for more details on the StenUNet algorithm.
Figure 2: The proposed UNet-based StenUNet for stenosis detection. The reader is referred to Section 2 for more details on the StenUNet algorithm.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.