Skip to main content
QUICK REVIEW

[Paper Review] Stripped-envelope core-collapse supernova $^{56}$Ni masses: Persistently larger values than supernovae type II

N. Meza, J. P. Anderson|arXiv (Cornell University)|Feb 3, 2020
Gamma-ray bursts and supernovaePhysics and Astronomy120 references10 citations
TL;DR

This study re-evaluates ⁵⁶Ni masses in stripped-envelope core-collapse supernovae (SE-SNe: IIb, Ib, Ic) using three uniform methods—Arnett’s rule, Khatami & Kasen’s prescription, and tail luminosity—finding consistently higher ⁵⁶Ni yields in SE-SNe than in hydrogen-rich Type II SNe, indicating intrinsic astrophysical differences rather than methodological bias.

ABSTRACT

The mass of synthesised radioactive material is an important power source for all supernova (SN) types. Anderson 2019 recently compiled literature values and obtained $^{56}$Ni distributions for different core-collapse supernovae (CC-SNe), showing that the $^{56}$Ni distribution of stripped envelope CC-SNe (SE-SNe: types IIb, Ib, and Ic) is highly incompatible with that of hydrogen rich type II SNe (SNe-II). This motivates questions on differences in progenitors, explosion mechanisms, and $^{56}$Ni estimation methods. Here, we re-estimate the nucleosynthetic yields of $^{56}$Ni for a well-observed and well-defined sample of SE-SNe in a uniform manner. This allows us to investigate whether the observed SN-II--SE-SN $^{56}$Ni separation is due to real differences between these SN types, or because of systematic errors in the estimation methods. We compiled a sample of well observed SE-SNe and measured $^{56}$Ni masses through three different methods proposed in the literature. Arnett's rule -as previously shown - gives $^{56}$Ni masses for SE-SNe that are considerably higher than SNe-II. While for the distributions calculated using both the Khatami&Kasen prescription and Tail $^{56}$Ni masses are offset to lower values than `Arnett values', their $^{56}$Ni distributions are still statistically higher than that of SNe II. Our results are strongly driven by a lack of SE-SN with low $^{56}$Ni masses (that are in addition strictly lower limits). The lowest SE-SN $^{56}$Ni mass in our sample is of 0.015M$_\odot$, below which are more than 25$\%$ of SNe II. We conclude that there exists real, intrinsic differences in the mass of synthesised radioactive material between SNe II and SE-SNe . Any proposed current or future CCSN progenitor scenario and explosion mechanism must be able to explain why and how such differences arise, or outline a yet to be fully explored bias in current SN samples.

Motivation & Objective

  • To investigate whether the observed discrepancy in ⁵⁶Ni masses between stripped-envelope (SE-SNe) and hydrogen-rich Type II SNe is due to systematic errors in estimation methods or real astrophysical differences.
  • To re-estimate ⁵⁶Ni masses for a well-observed, homogeneous sample of SE-SNe using multiple, consistent methods to minimize methodological bias.
  • To determine whether the previously reported higher ⁵⁶Ni yields in SE-SNe are robust across different estimation techniques or artifacts of inconsistent literature measurements.
  • To assess whether the lack of low-⁵⁶Ni-mass SE-SNe in the sample contributes to the observed statistical separation from Type II SNe.

Proposed method

  • Compiled a sample of well-observed SE-SNe with low redshift (z ≤ 0.03) and precise explosion epoch estimates (mean uncertainty <7 days).
  • Applied three independent ⁵⁶Ni mass estimation techniques: Arnett’s rule (energy budget from early light curve), Khatami & Kasen’s method (radiative transfer and energy deposition), and tail luminosity (lower limit based on late-time decay).
  • Used homogeneous photometric and spectroscopic data to derive light curves and ejecta properties for consistent comparison across methods.
  • Compared the resulting ⁵⁶Ni distributions from each method with the literature compilation by Anderson (2019) to assess consistency and statistical significance.
  • Performed statistical tests to evaluate whether the observed ⁵⁶Ni distribution differences between SE-SNe and SNe II are significant and not due to sample bias.
  • Accounted for extinction using Milky Way and host galaxy E(B-V) values to correct observed magnitudes and luminosities.

Experimental results

Research questions

  • RQ1Are the higher ⁵⁶Ni masses observed in SE-SNe compared to SNe II due to systematic errors in estimation methods or intrinsic astrophysical differences?
  • RQ2How do different ⁵⁶Ni mass estimation techniques (Arnett, Khatami & Kasen, tail luminosity) compare in their results for the same SE-SN sample?
  • RQ3Is the observed absence of low-⁵⁶Ni-mass SE-SNe (e.g., <0.015 M☉) in the sample responsible for the statistical separation from SNe II?
  • RQ4Can the ⁵⁶Ni yield distribution of SE-SNe be reconciled with current progenitor and explosion models, or do they require new physical explanations?

Key findings

  • Arnett’s rule yields ⁵⁶Ni masses for SE-SNe that are significantly higher than those for SNe II, confirming prior literature findings.
  • Even when using the Khatami & Kasen prescription and tail luminosity (lower limit) methods, SE-SN ⁵⁶Ni distributions remain statistically higher than those of SNe II.
  • The lowest ⁵⁶Ni mass in the SE-SN sample is 0.015 M☉, below which more than 25% of SNe II lie, indicating a genuine deficit of low-⁵⁶Ni-mass SE-SNe.
  • The persistent separation in ⁵⁶Ni mass distributions across all three methods strongly suggests real astrophysical differences rather than systematic errors in estimation.
  • The results imply that current progenitor and explosion models must account for why SE-SNe produce more ⁵⁶Ni on average than SNe II.
  • The lack of low-⁵⁶Ni-mass SE-SNe may point to a selection bias or a fundamental difference in progenitor structure or explosion mechanism.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.