[Paper Review] Super-Resolution and Denoising of Corneal B-Scan OCT Imaging Using Diffusion Model Plug-and-Play Priors
This paper presents a diffusion-model plug-and-play priors framework to achieve 4x super-resolution and denoising of corneal B-scan OCT images, formulated as a Bayesian inverse problem with MCMC sampling and pretrained priors.
Optical coherence tomography (OCT) is pivotal in corneal imaging for both surgical planning and diagnosis. However, high-speed acquisitions often degrade spatial resolution and increase speckle noise, posing challenges for accurate interpretation. We propose an advanced super-resolution framework leveraging diffusion model plug-and-play (PnP) priors to achieve 4x spatial resolution enhancement alongside effective denoising of OCT Bscan images. Our approach formulates reconstruction as a principled Bayesian inverse problem, combining Markov chain Monte Carlo sampling with pretrained generative priors to enforce anatomical consistency. We comprehensively validate the framework using \emph{in vivo} fisheye corneal datasets, to assess robustness and scalability under diverse clinical settings. Comparative experiments against bicubic interpolation, conventional supervised U-Net baselines, and alternative diffusion priors demonstrate that our method consistently yields more precise anatomical structures, improved delineation of corneal layers, and superior noise suppression. Quantitative results show state-of-the-art performance in peak signal-to-noise ratio, structural similarity index, and perceptual metrics. This work highlights the potential of diffusion-driven plug-and-play reconstruction to deliver high-fidelity, high-resolution OCT imaging, supporting more reliable clinical assessments and enabling advanced image-guided interventions. Our findings suggest the approach can be extended to other biomedical imaging modalities requiring robust super-resolution and denoising.
Motivation & Objective
- Motivate high-fidelity corneal OCT imaging for surgical planning and diagnosis by addressing degraded resolution and speckle noise in fast acquisitions.
- Develop a 4x super-resolution and denoising framework that preserves anatomical consistency in OCT B-scans.
- Leverage diffusion priors within a principled Bayesian reconstruction to improve delineation of corneal layers.
Proposed method
- Formulate reconstruction as a Bayesian inverse problem combining a diffusion-model prior with measurements.
- Use Markov chain Monte Carlo sampling to enforce anatomical consistency during reconstruction.
- Employ pretrained generative priors as plug-and-play components to guide super-resolution and denoising.
- Validate on in vivo fisheye corneal datasets to assess robustness across clinical settings.
- Compare against bicubic interpolation, supervised U-Net baselines, and alternative diffusion priors.
- Report improvements in anatomical fidelity, layer delineation, and noise suppression.
Experimental results
Research questions
- RQ1Can diffusion model plug-and-play priors enable 4x super-resolution of corneal OCT B-scans while denoising effectively?
- RQ2Does the Bayesian reconstruction with MCMC sampling yield anatomically consistent and higher-quality OCT images compared to traditional methods?
- RQ3How does the proposed method perform on in vivo fisheye corneal datasets across diverse clinical settings?
- RQ4Do diffusion-prior-based reconstructions improve PSNR, SSIM, and perceptual metrics relative to baselines?
- RQ5Is the approach extendable to other biomedical imaging modalities requiring robust super-resolution and denoising?
Key findings
- The method achieves 4x spatial resolution enhancement with effective denoising.
- Compared to bicubic interpolation and conventional U-Net baselines, the approach yields more precise anatomical structures and better delineation of corneal layers.
- Diffusion-prior and MCMC-based reconstruction provide superior noise suppression and higher-quality images.
- Quantitative results show state-of-the-art performance in peak signal-to-noise ratio, structural similarity index, and perceptual metrics.
- Validation on in vivo datasets demonstrates robustness and scalability across clinical settings.
- The approach has potential for extension to other biomedical imaging modalities requiring robust super-resolution and denoising.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.