[Paper Review] Temperature mapping of stacked silicon dies from x-ray diffraction intensities

Darshan Chalise, Péter Kenesei|arXiv (Cornell University)|Mar 23, 2022
Integrated Circuits and Semiconductor Failure AnalysisEngineering32 references5 citations
TL;DR

This paper presents a non-invasive x-ray diffraction method that maps 3D temperature distributions in stacked silicon dies by measuring the temperature dependence of X-ray diffraction intensity via the Debye-Waller factor. Using synchrotron radiation at 72 keV, the technique achieves 3 K temperature resolution, 100 µm × 400 µm spatial resolution, and 20 s temporal resolution, enabling simultaneous thermal mapping of individual dies in a 3D IC stack.

ABSTRACT

Increasing power densities in integrated circuits has led to an increased prevalence of thermal hotspots in integrated circuits. Tracking these thermal hotspots is imperative to prevent circuit failures. In 3D integrated circuits, conventional surface techniques like infrared thermometry are unable to measure 3D temperature distribution and optical and magnetic resonance techniques are difficult to apply due to the presence of metals and large current densities. X-rays offer high penetration depth and can be used to probe 3D structures. We report a method utilizing the temperature dependence of x-rays diffraction intensity via the Debye-Waller factor to simultaneously map the temperature of an individual silicon die that is a part of a stack of dies. Utilizing beamline 1-ID-E at the Advanced Photon Source (Argonne), we demonstrate for each individual silicon die, a temperature resolution of 3 K, a spatial resolution of 100 um x 400 um and a temporal resolution of 20 s. Utilizing a sufficiently high intensity laboratory source, e.g., from a liquid anode source, this method can be scaled down to laboratories for non-invasive temperature mapping of 3D integrated circuits.

Motivation & Objective

  • To address the challenge of tracking thermal hotspots in 3D integrated circuits where conventional surface techniques fail.
  • To develop a non-invasive method for 3D temperature mapping in stacked silicon dies with high spatial and temporal resolution.
  • To leverage the temperature dependence of X-ray diffraction intensity via the Debye-Waller factor for accurate thermometry in multilayered semiconductor structures.
  • To demonstrate feasibility for laboratory-scale implementation using high-intensity lab sources such as liquid anode x-ray tubes.

Proposed method

  • The method uses raster scanning of a focused X-ray beam across the stacked dies to collect diffraction intensity maps.
  • Temperature is inferred from the relative change in diffraction intensity of the (16 0 0) peak, which depends on the Debye-Waller factor.
  • The Debye-Waller factor is calculated using the Debye model, relating atomic displacement to temperature via the formula: ( ) = 2π²⟨u²⟩ / λ², where ⟨u²⟩ is the mean square atomic displacement.
  • Spatial separation of diffracted beams from different dies enables simultaneous temperature mapping of individual layers.
  • The technique relies on kinematic diffraction theory, validated for undoped and n-type silicon, assuming negligible multiple scattering.
  • High-energy X-rays (72 keV) are used to achieve high momentum transfer and sufficient penetration depth through multiple silicon and copper layers.

Experimental results

Research questions

  • RQ1Can X-ray diffraction intensity be used to map 3D temperature distributions in stacked silicon dies with high spatial and temporal resolution?
  • RQ2What is the sensitivity of the (16 0 0) diffraction peak to temperature changes via the Debye-Waller factor?
  • RQ3Can this method achieve sub-3 K temperature resolution in a multilayered 3D IC structure?
  • RQ4Is the technique scalable to laboratory environments using compact high-flux X-ray sources?
  • RQ5What are the dominant sources of intensity variation that affect temperature uncertainty in the measurement?

Key findings

  • The method achieved a temperature resolution of 3 K, with a 2.5% intensity deviation at room temperature contributing to this uncertainty.
  • Spatial resolution of 100 µm × 400 µm was achieved, limited by the beam spot size.
  • Temporal resolution of 20 s per measurement point was demonstrated using beamline 1-ID-E at the Advanced Photon Source.
  • The (16 0 0) peak intensity showed a temperature sensitivity of approximately 2.5% per 100 K, consistent with theoretical predictions from the Debye-Waller factor.
  • Systematic intensity variations of ~2.5–3% across the die surface were observed, likely due to alignment imperfections or material inhomogeneities rather than noise.
  • The method is scalable to laboratory use with high-intensity sources such as liquid metal anode x-ray tubes, which provide ~10⁸ photons/s and energies >20 keV.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.