Skip to main content
QUICK REVIEW

[Paper Review] The Design of a Novel Prismatic Drive for a Three-DOF Parallel-Kinematics Machine

Renotte, Jérome, Damien Chablat|arXiv (Cornell University)|May 9, 2007
Mechanical Engineering and Vibrations ResearchEngineering9 references5 citations
TL;DR

This paper presents a novel non-coaxial conjugate-cam mechanism as a prismatic actuator for a three-degree-of-freedom parallel-kinematics machine (Orthoglide), replacing ball screws with a Slide-O-Cam transmission that enables pure-rolling contact to reduce friction and wear. The optimized design achieves a service factor of 88.03% with minimal roller-pin deformation (9.76 μm) and low pressure angle variation, enhancing precision and durability in high-acceleration machining applications.

ABSTRACT

The design of a novel prismatic drive is reported in this paper. This transmission is based on Slide-O-Cam, a cam mechanism with multiple rollers mounted on a common translating follower. The design of Slide-O-Cam was reported elsewhere. This drive thus provides pure-rolling motion, thereby reducing the friction of rack-and-pinions and linear drives. Such properties can be used to design new transmissions for parallel-kinematics machines. In this paper, this transmission is optimized to replace ball-screws in Orthoglide, a three-DOF parallel robot optimized for machining applications.

Motivation & Objective

  • To replace ball screws in the Orthoglide parallel robot with a more efficient, low-friction actuation system.
  • To address the limitations of ball screws, such as high wear, point contact, and complex moving parts.
  • To develop a prismatic drive based on the Slide-O-Cam mechanism that enables pure-rolling motion for improved load capacity and reduced friction.
  • To optimize the cam profile and design parameters for geometric feasibility, convexity, and avoidance of undercutting.
  • To achieve a high service factor and low pressure angle variation for reliable, high-precision operation in machining applications.

Proposed method

  • The Slide-O-Cam mechanism uses multiple rollers mounted on a translating follower, with power transmitted via pure-rolling contact between cam and roller bearings.
  • The input-output function is defined as s(ψ) = (p/(2π))ψ - p/2, with p = 50 mm, ensuring a 50 mm displacement per full cam rotation.
  • Geometric constraints are enforced using the Aronhold-Kennedy theorem to derive cam profile equations in the u-v frame, with parameters b₂, b₃, and δ determined from kinematic relations.
  • The pressure angle μ is analyzed as a key performance metric, with design optimized to minimize its maximum absolute value while maintaining geometric feasibility.
  • A non-coaxial conjugate-cam configuration is implemented with three cams spaced at 120° intervals, allowing continuous motion transmission by switching drive roles between cams.
  • Roller-pin deformation is modeled using beam theory, with maximum deformation vLmax calculated from material properties (E = 2×10⁵ MPa), load (τ = 1.2 Nm), and geometry.

Experimental results

Research questions

  • RQ1How can a cam-based prismatic actuator be designed to replace ball screws in a three-DOF parallel robot like Orthoglide?
  • RQ2What geometric and kinematic constraints must be satisfied to ensure a fully convex, undercut-free cam profile with pure-rolling contact?
  • RQ3How can the pressure angle distribution be optimized to improve load capacity and reduce stress and wear?
  • RQ4What is the optimal balance between roller radius, cam profile, and deformation to maximize service factor while maintaining precision?
  • RQ5How does a non-coaxial conjugate-cam mechanism enable continuous, smooth motion transmission across multiple cam phases?

Key findings

  • The optimal design uses η = 0.37, resulting in a roller radius a₄ = 9 mm and a maximum roller-pin deformation of 9.76 μm.
  • The maximum pressure angle is 32.95°, and the minimum is 17.75°, with a service factor of 88.03%, indicating high mechanical reliability.
  • The non-coaxial configuration reduces peak pressure angles by avoiding high-stress regions of the cam profile, improving load distribution.
  • The mechanism achieves a 50 mm displacement per full cam rotation (p = 50 mm), matching the original Orthoglide ball screw pitch.
  • The use of three cams spaced at 120° intervals ensures continuous motion transmission with smooth handover between active cams.
  • The design achieves a 100% service factor at η = 0.33 and below, but with excessive deformation (147.02 μm), making it impractical for precision applications.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.