TL;DR

This paper presents the first 1.5 years of operation of the TOTEM Roman Pot system at the LHC, detailing its movement control, position interlock system, and beam-based and software alignment techniques. It achieves sub-micron precision in RP positioning and alignment, enabling accurate measurement of elastic and diffractive proton-proton scattering down to 10⁻³ GeV² in four-momentum transfer.

ABSTRACT

Since the LHC running season 2010, the TOTEM Roman Pots (RPs) are fully operational and serve for collecting elastic and diffractive proton-proton scattering data. Like for other moveable devices approaching the high intensity LHC beams, a reliable and precise control of the RP position is critical to machine protection. After a review of the RP movement control and position interlock system, the crucial task of alignment will be discussed.

Motivation & Objective

  • To ensure safe and precise operation of movable Roman Pots near high-intensity LHC beams through a robust control and interlock system.
  • To achieve sub-micron positioning accuracy for Roman Pots to enable measurements of very forward proton scattering.
  • To develop and validate beam-based and software-based alignment techniques for accurate reconstruction of particle tracks.
  • To maintain machine protection by integrating the RP system with the LHC beam interlock logic.
  • To calibrate and cross-check position measurements using redundant encoder and LVDT systems.

Proposed method

  • Utilized a hierarchical control architecture derived from LHC collimator systems, with user interface at CCC, FESA-based supervisor at middle level, and PXI-based low-level motor control.
  • Employed dual redundant position measurements: motor step counters (relative to OUT stopper) and LVDTs (absolute, with drift correction).
  • Implemented a beam interlock logic using FPGA cards that compare RP positions to beam-mode-dependent critical limits and enforce beam dump or extraction if unsafe.
  • Performed beam-based alignment by scraping the beam halo with primary collimators and using BLM signals to identify the beam edge at 10–250 μm step sizes.
  • Used track residuals from reconstructed particle events to determine relative sensor misalignments, with overlap between vertical and horizontal detectors enabling unit-level alignment.
  • Applied symmetry constraints from elastic scattering distributions to determine global alignment with sub-10 μm precision.

Experimental results

Research questions

  • RQ1How can the TOTEM Roman Pots be safely and precisely controlled during operation near the LHC beam?
  • RQ2What is the performance of the dual-position measurement system (encoders and LVDTs) in maintaining accurate RP positioning?
  • RQ3How effective is the beam interlock logic in preventing beam injection or triggering automatic extraction when RPs are in unsafe positions?
  • RQ4What is the achievable alignment precision of the RPs using beam-based and software-based techniques?
  • RQ5To what extent can symmetry in elastic scattering distributions constrain global alignment of RP stations?

Key findings

  • The RP movement control system successfully maintained precise and safe operation over 1.5 years of LHC running, with position control down to 5 μm per motor step.
  • The beam interlock system correctly triggered automatic RP retraction when position limits were violated, as demonstrated in interlock test sequences.
  • Beam-based alignment achieved a precision of 10–250 μm, later improved to 10 μm step size, enabling accurate determination of the beam edge relative to the RP.
  • Software-based alignment using track residuals constrained relative sensor misalignments, with global alignment precision better than 10 μm horizontally and 20 μm vertically.
  • Symmetry-based alignment of elastic scattering hit distributions allowed precise determination of beam centre position, with the beam centre found to within ~10 μm.
  • LVDT measurements provided reliable absolute position data, though subject to small drifts requiring periodic recalibration.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.