Andrew Hime|arXiv (Cornell University)|Oct 5, 2011
Dark Matter and Cosmic PhenomenaPhysics and Astronomy5 references23 citations
TL;DR

The MiniCLEAN experiment proposes a single-phase liquid-argon time-projection chamber with 4π photomultiplier coverage to detect dark matter WIMPs via scintillation light. It leverages pulse-shape discrimination and event reconstruction to suppress backgrounds, with a secondary liquid-neon run for cross-checking signal and interaction rate dependence.

ABSTRACT

The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with photomultiplier tubes submerged in the cryogen with nearly 4pi coverage of a 500 kg (150 kg) target (fiducial) mass. The high light yield and unique properties of the scintillation time-profile provide effective defense against radioactive background through pulse-shape discrimination and event-position reconstruction. The detector is designed also for a liquid-neon target that allows for an independent verification of signal and background and a test of the expected dependence of the WIMP-nucleus interaction rate.

Motivation & Objective

  • To develop a high-sensitivity dark matter detector using liquid-argon scintillation for WIMP detection.
  • To achieve near-4π coverage of the liquid-argon target using submerged photomultiplier tubes to maximize signal collection.
  • To suppress radioactive backgrounds through pulse-shape discrimination based on the unique scintillation time profile of argon.
  • To enable independent verification of signals and WIMP-nucleus interaction rate dependence via a secondary liquid-neon detector option.
  • To provide a scalable, background-resistant platform for direct dark matter detection with high fiducial mass.

Proposed method

  • Utilize a single-phase liquid-argon time-projection chamber with photomultiplier tubes submerged directly in the cryogenic fluid.
  • Achieve nearly 4π angular coverage of the detector volume using an array of photomultiplier tubes around the target.
  • Leverage the fast scintillation component (nanosecond-scale) of liquid argon to enable pulse-shape discrimination against background events.
  • Reconstruct event positions using time-of-flight information from multiple PMTs to further suppress backgrounds.
  • Design the detector to be adaptable for a liquid-neon target to cross-validate signals and test interaction rate scaling.
  • Use the distinct scintillation time profile of neon to independently verify signal characteristics and background rejection.

Experimental results

Research questions

  • RQ1Can pulse-shape discrimination in liquid argon effectively suppress radioactive backgrounds in direct dark matter searches?
  • RQ2To what extent does 4π photomultiplier coverage improve detection efficiency and background rejection in a single-phase TPC?
  • RQ3How does the WIMP-nucleus interaction rate scale with target material, and can liquid neon provide independent confirmation of this scaling?
  • RQ4Can the detector's design be extended to liquid neon while maintaining high signal-to-background discrimination?
  • RQ5What is the achievable fiducial mass and background level in a large-scale liquid-argon TPC with submerged PMTs?

Key findings

  • The MiniCLEAN design achieves nearly 4π photomultiplier coverage using submerged PMTs, maximizing light collection and event reconstruction accuracy.
  • The scintillation time profile in liquid argon enables effective pulse-shape discrimination, allowing rejection of dominant radioactive backgrounds.
  • Event position reconstruction from time-of-flight differences between PMTs enhances background suppression and signal identification.
  • The inclusion of a liquid-neon target option provides a critical independent test of signal consistency and WIMP-nucleus interaction rate dependence.
  • The detector concept is scalable and suitable for large fiducial masses, with a 150 kg fiducial mass target in the initial design.
  • The experiment is designed to achieve high sensitivity to WIMP-nucleon scattering cross sections while maintaining low background levels through multiple discrimination techniques.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.