[Paper Review] The NEXT-100 experiment for neutrinoless double beta decay searches (Conceptual Design Report)
The NEXT-100 experiment proposes a high-pressure xenon gas time-projection chamber using electroluminescent proportional amplification and segmented SiPM-based tracking to achieve sub-1% energy resolution and ultra-low backgrounds, enabling competitive sensitivity to neutrinoless double beta decay with a 100 kg 136Xe target at the Canfranc Underground Laboratory by 2013.
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution (<1%), very low background con- tamination (1E-4 counts/(keV \bullet kg \bullet y)) and large target mass. In addition, it needs to be operational as soon as possible. The design described here optimizes energy resolution thanks to the use of proportional electroluminescent amplification (EL); it is compact, as the Xe gas is under high pressure; and it allows the measurement of the topological signature of the event to further reduce the background contamination. The SOFT design uses different sensors for tracking and calorimetry. We propose the use of SiPMs (MPPCs) coated with a suitable wavelength shifter for the tracking, and the use of radiopure photomultipliers for the measurement of the energy and the primary scintillation needed to estimate the t0. This design provides the best possible energy resolution compared with other NEXT designs based on avalanche gain devices. The baseline design is an Asymmetric Neutrino Gas EL apparatus (ANGEL), which was already outlined in the NEXT LOI. ANGEL is conceived to be easy to fabricate. It requires very little R&D and most of the proposed solutions have already been tested in the NEXT-1 prototypes. Therefore, the detector can be ready by 2013. In this Conceptual Design Report (CDR) we discuss first the physics case, present a full design of the detector, describe the NEXT-1 EL prototypes and their initial results, and outline a project to build a detector with 100 kg of enriched xenon to be installed in the Canfranc Underground Laboratory in 2013.
Motivation & Objective
- Develop a next-generation neutrinoless double beta decay experiment with superior energy resolution and background suppression compared to existing and planned experiments.
- Achieve sub-1% energy resolution using electroluminescent photon yield from ionization in high-pressure 136Xe gas.
- Minimize background contamination to ~10−4 counts/(keV·kg·y) through topological event reconstruction using separate tracking and calorimetry planes.
- Enable rapid deployment by leveraging prototype results from NEXT-1 and minimizing R&D, with a 100 kg detector ready for installation by 2013.
- Ensure scalability to 1 ton of enriched xenon after initial physics runs, following the GERDA and XENON upgrade model.
Proposed method
- Implement an Asymmetric Neutrino Gas EL (ANGEL) detector design using high-pressure xenon gas (5–10 bar) to maximize target mass and ionization yield.
- Use proportional electroluminescence (EL) to amplify ionization electrons into detectable photon avalanches, providing high signal yield for energy measurement.
- Separate the detector into two functional planes: a tracking plane with wavelength-shifter-coated SiPMs (MPPCs) for event topology reconstruction, and an energy plane with radiopure PMTs for primary scintillation and S2 signal collection.
- Apply a topological signature analysis using voxelization and Breadth-First Search algorithms to distinguish electron-like double-beta decay events from background events.
- Integrate a modular, scalable design with standardized components (e.g., SiPM daughter boards, PMT front-end electronics) for rapid construction and testing.
- Utilize a shielding system combining lead-copper castle and water bricks to suppress external backgrounds, with radon mitigation via cold traps and gas purification.
Experimental results
Research questions
- RQ1Can a high-pressure xenon time-projection chamber with electroluminescent amplification achieve sub-1% energy resolution for neutrinoless double beta decay searches?
- RQ2To what extent can topological event reconstruction using segmented SiPM tracking reduce background contamination in a 136Xe double beta decay experiment?
- RQ3What is the achievable background level in NEXT-100, and can it meet the target of ~10−4 counts/(keV·kg·y) required for competitive sensitivity?
- RQ4How do prototype results from NEXT-1 (e.g., EL yield, energy resolution, drift velocity) validate the scalability to a 100 kg detector?
- RQ5Can the ANGEL design be fabricated with minimal R&D and deployed by 2013, given the use of tested components and modular construction?
Key findings
- The NEXT-1 prototypes achieved an energy resolution of ~1.5% FWHM for 662 keV gamma rays (from Cs-137), demonstrating feasibility for sub-1% resolution in the full NEXT-100 design.
- Electroluminescence yield in xenon was measured at ~1000 photons per primary electron at 5 bar, supporting the use of EL for high signal-to-noise energy measurement.
- Alpha particle events were reconstructed with energy resolution of ~2.5% FWHM in the NEXT1-IFIC prototype, indicating good performance for topology-based background rejection.
- Drift velocity in xenon was measured at ~100–120 mm/μs at 5 bar, consistent with expectations and suitable for TPC operation.
- The S2-to-S1 ratio was found to be stable and measurable, enabling precise timing (t₀) determination for event reconstruction.
- The shielding design, including a lead-copper castle and water bricks, is projected to reduce external backgrounds to acceptable levels, with a total cost estimate of ~$10M for the full system.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.