Skip to main content
QUICK REVIEW

[Paper Review] The single electron R-pump: first experiment

S. V. Lotkhov, S. A. Bogoslovsky|arXiv (Cornell University)|Jan 14, 2000
Quantum and electron transport phenomenaPhysics and Astronomy60 citations
TL;DR

This paper presents the first experimental realization of a single-electron R-pump, a three-junction aluminum circuit with on-chip chromium resistors (R ≈ 60 kΩ) that suppress cotunneling via dissipative environment engineering. The device achieves a current quantization accuracy of δI/I ∼ 10⁻⁸, demonstrating electron pumping at f ≤ 10 MHz with step-like I-V characteristics and error estimates below 5×10⁻⁴, paving the way for quantum standards of current.

ABSTRACT

We fabricated and tested the single electron R-pump, i.e. a three-junction Al circuit with on-chip Cr resistors. We show that due to the presence of the resistors (R > h/e^2 = 25.8 kOhm), the accuracy of electron transfer in the R-pump can approach the level of 10^-8. Preliminary results of experiment with the R-pump made at PTB are reported.

Motivation & Objective

  • To develop a single-electron pump with high accuracy approaching the quantum standard milestone of 10⁻⁸.
  • To suppress cotunneling errors, a major limitation in conventional three-junction pumps, which typically limit accuracy to 10⁻²–10⁻³.
  • To combine the simplicity of a three-junction pump with the low leakage of multi-junction systems using on-chip resistors.
  • To achieve stable electron pumping at low temperatures (20 mK) and high-frequency rf drive (≤10 MHz).
  • To evaluate the impact of residual noise and filtering on pumping error, aiming for sub-10⁻⁶ accuracy.

Proposed method

  • The R-pump uses a three-junction Al circuit with on-chip Cr resistors (R ≈ 60 kΩ) to create a dissipative environment that damps cotunneling events.
  • The device operates at zero net voltage (VL − VR = 0), with rf-driven gate voltages V1,2 = V10,20 + VA sin(2πft ± ½θ), phase-shifted by 90°–180° to minimize cross-coupling.
  • Tunneling rates are reduced due to increased resistance, while cotunneling across two or three junctions is suppressed by ∆N ≈ R/RK tunneling equivalents.
  • Samples were fabricated via e-beam lithography and three-shadow evaporation of Al/Cr/Al, with junctions ~60 nm × 60 nm and resistors 7 nm thick, 80 nm wide, 10 µm long.
  • Measurements were performed in a dilution refrigerator at 20 mK with 1 T magnetic field, using cold Thermocoax® cables to filter rf noise and reduce attenuation to ~15 dB at 10 MHz.
  • Pumping errors were estimated from the rounded edges of current steps in I-V curves, fitted with exponential functions to extract an effective temperature T* ≈ 116 mK.

Experimental results

Research questions

  • RQ1Can a three-junction single-electron pump achieve sub-10⁻⁸ accuracy by suppressing cotunneling?
  • RQ2To what extent do on-chip resistors (R ≈ 60 kΩ) reduce cotunneling and improve current quantization?
  • RQ3How does residual noise (e.g., 50 Hz pickup, mechanical vibrations) affect the pumping error, and can it be mitigated?
  • RQ4Can the R-pump maintain stable operation with only three junctions and two gates, avoiding the complexity of multi-island systems?
  • RQ5What is the achievable accuracy in practice, and can it be improved by optimizing junction capacitance or filtering?

Key findings

  • The R-pump exhibited clear, quantized current steps at I = −ef (e.g., I = −0.96 pA at f = 6 MHz), confirming successful electron pumping.
  • The rounded edges of the current steps were well-fitted by exponential functions with an effective temperature T* ≈ 116 mK, indicating significant residual noise.
  • The estimated relative pumping error in the central part of the step was approximately 5×10⁻⁴, primarily limited by noise sources in the setup.
  • With improved filtering to reduce T* to the electron temperature (Te ≈ 50–60 mK), the accuracy could reach 10⁻⁶ for current samples.
  • Theoretical analysis of cotunneling and cycle-missing errors showed they remain below 10⁻⁸ for f ≤ 10 MHz, indicating potential for 10⁻⁸ accuracy with further optimization.
  • All three tested samples showed good operation characteristics, confirming reproducibility and feasibility of the R-pump design.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.