Skip to main content
QUICK REVIEW

[Paper Review] TotalSegmentator: robust segmentation of 104 anatomical structures in CT images

Jakob Wasserthal, Hanns‐Christian Breit|PubMed|Aug 11, 2022
Advanced X-ray and CT ImagingEngineering19 references279 citations
TL;DR

The authors train a publicly available nnU-Net model to robustly segment 104 anatomical structures in CT images, demonstrating high accuracy and broad applicability, including an aging analysis on a large whole-body CT cohort.

ABSTRACT

The developed model enables robust and accurate segmentation of 104 anatomic structures. The annotated dataset (<i>https://doi.org/10.5281/zenodo.6802613</i>) and toolkit (<i>https://www.github.com/wasserth/TotalSegmentator</i>) are publicly available.<b>Keywords:</b> CT, Segmentation, Neural Networks <i>Supplemental material is available for this article</i>. © RSNA, 2023See also commentary by Sebro and Mongan in this issue.

Motivation & Objective

  • Develop a segmentation model that automatically and robustly segments 104 anatomical structures in CT images.
  • Create a diverse, real-world training dataset and manual annotations to maximize generalizability.
  • Provide public access to the model and training data to enable broad adoption in research and clinical planning.

Proposed method

  • Use nnU-Net as the segmentation backbone with automatic configuration for the dataset.
  • Annotate 104 structures across 1204 CT examinations with iterative refinement to create ground truth.
  • Train separate high- and low-resolution models (1.5 mm and 3 mm) and evaluate with Dice and NSD metrics.
  • Compare with the BTCV public model to assess relative performance.
  • Apply the trained model to a separate aging dataset of 4004 whole-body CT scans to study age-related changes.

Experimental results

Research questions

  • RQ1Can a single model accurately segment 104 anatomical structures across diverse CT images?
  • RQ2How does the 1.5 mm resolution model compare to a 3 mm resolution model in segmentation accuracy and border precision?
  • RQ3Does the model generalize to external datasets (e.g., BTCV) and to aging analyses in a large polytrauma cohort?

Key findings

  • Dice score on the test set: 0.943 (95% CI 0.938–0.947).
  • 3 mm model Dice score: 0.840 (95% CI 0.836–0.844), NSD: 0.966 (95% CI 0.962–0.969).
  • Our 1.5 mm model outperformed BTCV-model-based nnU-Net on the test set (Dice 0.932 vs 0.871; p<0.001).
  • On BTCV data, our 1.5 mm model achieved Dice 0.849 and NSD 0.932.
  • Aging study showed significant correlations between age and volume/attenuation for multiple structures (e.g., aorta volume rs=0.64; p<0.001; autochthonous dorsal musculature attenuation rs=−0.74; p<0.001).
  • Model is publicly available with pretrained weights and training data (TotalSegmentator) and can run on CPU with <12 GB RAM.